• Title/Summary/Keyword: Thermal-Comfort

Search Result 700, Processing Time 0.024 seconds

Analysis of South Korea Outdoor Design Temperature with respect to Assigned Period of the Weather Data (기상 데이터 산정 기간에 따른 국내의 설계용 외기온도 분석)

  • Nam, A Young;Kim, Young Il;Chung, Kwang Seop
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.2
    • /
    • pp.1-8
    • /
    • 2017
  • Outdoor design temperature is important for selecting proper capacity of heating and cooling systems of a building to implement indoor thermal comfort and save energy consumption. The purpose of this study is to investigate the change of South Korea outdoor design temperature according to the assigned period. When outdoor design temperature of 8 locations calculated with the latest weather data during 2008~2015 years using ASHRAE Bin method are compared to the standard temperature of Ministry of Land, Infrastructure and Transport which is widely used for designing South Korea air-conditioning system at present, the maximum temperature difference becomes $0.97^{\circ}C$ for cooling, and $1.94^{\circ}C$ for heating. Due to wide outdoor temperature variation, update of outdoor design temperature based on recent weather data is recommended.

Development of Classification System for Thermal Comfort Behavior of Pigs by Image Processing and Neural Network (영상처리와 인공신경망을 이용한 돼지의 체온조절행동 분류 시스템 개발)

  • 장동일;임영일;장홍희
    • Journal of Biosystems Engineering
    • /
    • v.24 no.5
    • /
    • pp.431-438
    • /
    • 1999
  • The environmental control based on interactive thermoregulatory behavior for swine production has many advantages over the conventional temperature-based control methods. Therefore, this study was conducted to compare various feature selection methods using postural images of growing pigs under various environmental conditions. A color CCD camera was used to capture the behavioral images which were then modified to binary images. The binary images were processed by thresholding, edge detection, and thinning techniques to separate the pigs from their background. Following feature were used for the input patterns to the neural network ; \circled1 perimeter, \circled2 area, \circled3 Fourier coefficients (5$\times$5), \circled4 combination of (\circled1 + \circled2), \circled5 combination of (\circled1 + \circled3), \circled6 combination of (\circled2 + \circled3), and \circled7 combination of (\circled1 + \circled2 + \circled3). Using the above each input pattern, the neural network could classify training images with the success rates of 96%, 96%, 96%, 100%, 100%, 96%, 100%, and testing images with those of 88%, 86%, 93%, 96%, 91%, 90%, 98%, respectively. Thus, the combination of perimeter, area and Fourier coefficients of the thinning images as neural network features gave the best performance (98%) in the behavioral classification.

  • PDF

Effects of Long-term Heat Exposure on Adaptive Mechanism of Blood Acid-base in Buffalo Calves

  • Korde, J.P.;Singh, G.;Varshney, V.P.;Shukla, D.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.5
    • /
    • pp.742-747
    • /
    • 2007
  • In order to investigate the mechanism of adaptation to long-term heat stress, six female buffalo calves of about 7 to 8 months age, were exposed to the cool-comfort environment (THI 65) for 21 days to obtain normal values of blood acid-base. An adaptive response of acid-base regulation was determined to long term (21 days) exposure of buffalo calves to hot-dry (THI 80) and hot-humid (THI 84) conditions. Higher rectal temperature and respiratory rate was recorded under hot-humid exposure compared to hot-dry. Significant reduction in the rectal temperature and respiratory rate on day 21 of hot-dry exposure indicated early thermal adaptation compared to hot-humid. Decreasing rectal temperature and respiratory rate from day 1 to 21 was associated with concurrent decrease in blood pH and pCO2. Increased plasma chloride concentration with low base excess in blood and in extracellular fluid suggested compensatory response to respiratory alkalosis. Reduced fractional excretion of sodium with increased fractional excretion of potassium and urine flow rate indicated renal adaptive response to heat stress.

Operation Results and Utility of Dynamic Pricing Response Control-Applied VRF System in Summer Season

  • Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.3
    • /
    • pp.71-77
    • /
    • 2017
  • Dynamic pricing refers to a system in which a tariff varies, according to a level of charging and applied time depending on time change. The power billing system used in the Korean Electric Power Corporation (KEPCO) is based on time of use (TOU) pricing, which is one of the dynamic pricing systems. This paper aimed to determine the operational results of a variable refrigerant flow system, to which a new control algorithm was applied, in order to respond to dynamic pricing, in summer and the utility of the new control. To do this, real measured data was acquired from a VRF system installed in a building for educational purposes, where dynamic pricing was applied for about 100 days during summer time. At the maximum load operation time period in TOU, the new control minimized operation within the indoor comfort range, an increase in refrigerant evaporation temperature in the indoor unit and the number of revolutions in a compressor in the outdoor unit was limited. As a result, power usage was decreased by 11%, and the operational cost by 14.6%. Furthermore, measurement results using the Predicted Mean Vote (PMV) model, that represented satisfaction of thermal environment, showed that 82.8% to 90.4% of the occupants of the building were satisfied during operation when the new control was applied.

A study of the Possibility of the Charcoal as Desiccant (흡착제로서 숯의 이용 가능성에 대한 연구)

  • Kim, Jong-Ryeol
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.5
    • /
    • pp.1083-1089
    • /
    • 2014
  • The aims of this study are to find out the possibility of the charcoal as a desiccant. The only humidity control under high temperature and high humidity environment can be provided to the thermal comfort at indoor environment. Functionality of charcoal is known to be deodorization, antiseptic effect, filtering effect and humidity control. But research related to humidity control in the country not yet. Thus, the dehumidification capacity of the charcoal experimental results to see the results were as follows : 1) Entering the experimental humidification is 148.02 g/h, 161.05 g/h and 243.2 g/h when air velocity was changed 1.5 m/s, 1.7 m/s and 2.0 m/s. 2) When the basis weight of the charcoal 2.0 m/s air velocity to obtain the largest number of adsorption capacity. 3) Dru bulb temperature and dew point temperature ware measured at front and rear of the charcoal. Absolute humidity is calculated from the measured Dry bulb temperature and dew point temperature. The quantity of dehumidification is calculated from absolute humidity is the largest 129.6 g/h at the air velocity 2.0 m/s.

Performance Analysis of Combined Passive Solar System for Building South Wall (남측외벽에 적용한 혼합형 태양열시스템의 성능 분석)

  • Yun, Tae-Gyun;Lee, Hyun-Soo;Jang, Hyang-In;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.42-49
    • /
    • 2012
  • In this article, the author carried out a theoretical study on the application techniques of a new Combined Passive Solar System (hereinafter referred to as the CPSS) of direct gain and trombe walls to get quick morning heating and to prevent afternoon overheating for office building. The numerical model proposed in this study can be used for the performance analysis of the CPSS in the winter and summer. Heating and Cooling loads are analysed for building energy consumption reduction using this numerical model. The results indicate that CPSS in the winter and summer modes could provide profitable conditions for improvement of indoor thermal comfort control and energy saving. consequently, the application of CPSS will not lead to significant reductions in the auxiliary air conditioning demand but also realize the environmentally friendly building.

The Analysis of Wind Data at the Cities in Korea with Meteorological Administration Data -Wind Data Analysis in 32 Cities During 30 Years- (기상청 자료를 이용한 도시의 바람자료 분석 연구 - 32개 도시의 30년간 바람자료 분석 -)

  • Yoon, Jae-ock
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.5-12
    • /
    • 2003
  • Using the wind, we can get a thermal comfort in summer. In winter we must shut out the wind. To achieve sustainable environmental building design, especially wind data is very important. The wind direction and wind velocity of 32 cities were analyzed to suggest the wind map of Korea. The weather data which was used in this paper was from National Weather Service(19711.1~2000.12.31). The results of this study are 1) The monthly wind velocity of Seoul is 1.1m/s-3.8m/s. 2) The maximum wind velocity could be estimated from the annual average wind velocity. The regression curve is Y(The maximum wind velocity)=6.369732 X(annual average wind velocity) + 6.391668 (P< 9.66E-12). 3) The wind velocity at the inland area which is far from 25km sea side is smaller than coastal area. The distance from the sea is major index of wind velocity. 4) The monthly wind direction was compared inland area with coastal area. 5) The uniform-velocity line on the Korean map was obtained.

Comparison of the PMV and ADPI according to Adapted Height of Ceiling-type System Air-conditioner in Large space (천정형 정풍량 시스템에어컨의 적용높이에 따른 실내온열환경 특성)

  • Sung, Sang-Chul;Kim, Hyouk-Soon;Chin, Sim-Won;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.590-595
    • /
    • 2009
  • PMV and ADPI were numerically investigated in a large space of various ceiling height with air-conditioning systems of two type. The numerical results showed that it is small that the growth of cooling load according to ceiling height rise in a large space without windows. In case of system air-conditioner of duct type embedded in the ceiling, the air mixing effect in indoor is superior to a case installed 4way cassette type in it. For controling thermal comfort at indoor, a system air-conditioner of duct type embedded in the ceiling is little influenced according to ceiling height rise in a large space considered.

  • PDF

Study on the Operation Strategy of A Building with Multi-Complex Spaces (복합 공간 구성 건물의 공조구역 운영 전략에 따른 에너지부하 특성 연구)

  • Yook, In-Soo;Kim, Min-Hwan;Nam, Hyeon-Jin;Kim, Dong-Ho;Seol, Dong-Mun;Lee, Geon-Tae;Kim, Jin-Ho S.;Kim, Jae-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.108-113
    • /
    • 2009
  • Buildings with multi-complex spaces designed for architectural values and functional requirements give rise to technical challenges in terms of energy efficiency and thermal comfort. Since spaces in such buildings are connected with openings with geometrical complexity, it is hard to define zoning plan and to control heating/cooling loads effectively. This paper presents a case study on the evaluation of operation strategy for a building with multi-complex spaces using computer simulation. The modelling methodology and the results of the simulations are also described.

  • PDF

A Development of the Performance Analysis Program Package of the Automatic Temperature Control System for Heating (난방용 자동온도조절기 성능분석용 프로그램 및 패키지 개발)

  • Kim, Yong-Ki;Woo, Nam-Sub;Lee, Tae-Won;Ahn, Byung-Cheon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1209-1214
    • /
    • 2009
  • Various automatic temperature control systems have been used widely in Korea for the conservation of heating energy and the enhancement of thermal comfort in residential buildings. But the heating control performance for automatic temperature control systems extensively vary with the design and operational conditions of the heating system, the climate condition and others. It was introduced in this study a numerical calculation program package to analyze heating control characteristics of the automatic temperature control system. This package is able to analyze the room air temperature, return water temperature, supplied heating flux and flow rate, and so on. One the other hand, the simulation results were verified by comparing with the field test results.

  • PDF