• Title/Summary/Keyword: Thermal waste water

Search Result 218, Processing Time 0.021 seconds

Characteristic of Light Weight Mortar using Waste Expanded Polystyrene and Expanded Polystyrene Beads (폐 발포폴리스티렌과 발포폴리스티렌 비드를 활용한 경량 모르타르의 특성)

  • Kang, Suk-Pyo;Hwang, Byoung-Il
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.393-401
    • /
    • 2017
  • This study presents an evaluation of basic properties of light weight mortar with expanded polystyrene bead(EPB) and waste expanded polystyrene(WEP) by varying replacement rations. In order to evaluate the basic properties of the light weight mortar with EPB and WEP, unit weight, compressive strength, flexural strength, water absorption ratio, thermal conductivity and distribution of polystyrene (EPB and WEP) in hardened mortar were performed. As a result, unit volume, compressive strength, bending strength, water absorption and thermal conductivity of light weight mortar were increased, but area distribution of polystyrene decreased with increasing the replacement ratio of WEP.

Evaluation on the buffer temperature by thermal conductivity of gap-filling material in a high-level radioactive waste repository

  • Seok Yoon;Min-Jun Kim ;Seeun Chang ;Gi-Jun Lee
    • Nuclear Engineering and Technology
    • /
    • v.54 no.11
    • /
    • pp.4005-4012
    • /
    • 2022
  • As high-level radioactive waste (HLW) generated from nuclear power plants is harmful to the human body, it must be safely disposed of by an engineered barrier system consisting of disposal canisters and buffer and backfill materials. A gap exists between the canister and buffer material in a HLW repository and between the buffer material and natural rock-this gap may reduce the water-blocking ability and heat transfer efficiency of the engineered barrier materials. Herein, the basic characteristics and thermal properties of granular bentonite, a candidate gap-filling material, were investigated, and their effects on the temperature change of the buffer material were analyzed numerically. Heat transfer by air conduction and convection in the gap were considered simultaneously. Moreover, by applying the Korean reference disposal system, changes in the properties of the buffer material were derived, and the basic design of the engineered barrier system was presented according to the gap filling material (GFM). The findings showed that a GFM with high initial thermal conductivity must be filled in the space between the buffer material and rock. Moreover, the target dry density of the buffer material varied according to the initial wet density, specific gravity, and water content values of the GFM.

A Study on the Electrochemical Properties of Water-soluble Waste Cutting Oil using Boron-Doped Diamond Electrodes (붕소도핑 다이아몬드 전극을 이용한 수용성 폐절삭유의 전기화학적 특성연구)

  • J.H., Park;T.G., Kim
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.6
    • /
    • pp.337-342
    • /
    • 2022
  • In metal cutting, water-soluble cutting oil is used for cooling the surface of the workpiece and improving the surface roughness. However, waste cutting oil contains preservatives and surfactants, and if it is discarded as it is, it has an great influence on environmental pollution. For this reason, regulations on the use of cutting oil are being stricter. Hence, the development of eco-friendly treatment technologies is required. In this study, a diamond electrode doped with boron on a niobium substrate was deposited by thermal filament chemical vapor deposition and waste cutting oil was treated using an electrochemical method. Compared to the total amount of organic carbon contained in the waste cutting oil, it was confirmed that the boron-doped diamonds developed from this study showed much better performance than electrodes that has been widely used before.

Computer Simulation of an Absorption Heat Pump for Recovering Low Grade Waste Heat (저온 폐열 회수를 위한 제1종 흡수식 열펌프의 컴퓨터 시뮬레이션)

  • Karng, S.W.;Kang, B.H.;Jeong, S.;Lee, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.2
    • /
    • pp.187-197
    • /
    • 1996
  • A computer program for thermal design analysis has been developed to predict the operating characteristics and performance of an absorption heat pump to recover $30{\sim}40^{\circ}C$ of waste hot water. The effects of heat transfer area of the system components, temperature and mass flow rate of heat transfer medium, and solution circulation rate on the system performance are investigated in detail. The results obtained indicate that the COP is increased with a decrease in the temperature of driving steam and with an increase in the temperature of waste hot water while the COP is little affected by the variation of a hot water temperature. It is also found that the heating output is increased with an increase in the temperature of waste hot water and driving steam as well as with a decrease in the temperature of hot water. The simulation results are also compared with the experimental results for a periodic operation of the system and obtained a satisfactory agreement.

  • PDF

Monitoring of hot waste water spread from coastal power station by the Landsat TM images (확산의 모니터링)

  • Cheoi, Seung-Pil;Yang, In-Tae;Lee, Kee-Boo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.6 no.1 s.11
    • /
    • pp.105-116
    • /
    • 1998
  • The spreading of hot waste water discharged from the coastal power station is a new problem to marin e circumstances and the fishery. Because the survey of hot waste water discharges should be performed is multaneously across wide areas, it is very difficult. Some sensors of the Landsat can draw the spread and distribution of water temperature from wavelength range of thermal infrared. The present study applied the GIS after stretching DN for the purpose of drawing a more accurate distribution of water temperature. Accordingly, the pattern of water temperature distribution could be expressed more precisely for a broad area, and the spread and distribution of hot waste water could be analyzed economically.

  • PDF

An Experimental Study on Heat Transfer Performance of Fluidized Bed Heat Exchanger for Heat Recovery from Multi-Heat Sources (다중열원 열회수형 유동층 열교환기의 전열성능에 대한 실험적 연구)

  • Park, Sang-Il;Ko, Chang-Bok;Lee, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2017
  • The heat transfer performance of a multi-heat-source fluidized bed heat exchanger was analyzed. The fluidized bed heat exchanger examined in this study can simultaneously recover the waste heat from gas, water vapor, and hot water. The effects of waste water flow rate, gas flow rate, and cooling water flow rate were examined to find their experimental correlations with the heat transfer coefficient. A computer program using the correlations was developed in this study to predict the thermal performance of the fluidized bed heat exchanger. The calculated heat transfer rates of gas, water vapor, waste water, and cooling water were compared with the measured values. It was found that the error of the calculated values was less than 12%.

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Hydrophobic Catalyst Mixture for the Isotopic Exchange Reaction between Hydrogen and Water

  • Paek S.;Ahn D.H.;Choi H.J.;Kim K.R.;LEE M.;YIM S.P.;CHUNG H.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.141-148
    • /
    • 2005
  • Pt/SDBC catalyst, which is used for the hydrogen-water isotopic exchange reaction, was prepared. The various properties of the catalyst, such as the thermal stability, pore structure and the platinum dispersion, were investigated. A hydrophobic Pt/SDBC catalyst which has been developed for the LPCE column of the WTRF (Wolsong Tritium Removal Facility) was tested in a trickle bed reactor. An experimental apparatus was built for the test of the catalyst at various temperatures and gas velocities.

  • PDF

Evaluation on Thermal Potential of Tap Water, Rain Water, Waste Water as City Water System (도시 수자원으로서의 상수.우수, 하수에 대한 열적 포텐셜의 평가)

  • ;大阪大學
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.26-33
    • /
    • 1998
  • It has been referred as a problem that heat source/sink is distance from heat demand area in using unused energy. To solve the distance problem in using unused energy, the water from city water system like tap water, rain water, waste water used as unused energy. To survey the potential of the water of city water system, it is developed that the calculation method of the potential using unit method. The amount of theoretical unused energy and energy saving in the Osaka City, Japan were estimated by using that method.

  • PDF

AN ANALYSIS OF THE THERMAL AND MECHANICAL BEHAVIOR OF ENGINEERED BARRIERS IN A HIGH-LEVEL RADIOACTIVE WASTE REPOSITORY

  • Kwon, S.;Cho, W.J.;Lee, J.O.
    • Nuclear Engineering and Technology
    • /
    • v.45 no.1
    • /
    • pp.41-52
    • /
    • 2013
  • Adequate design of engineered barriers, including canister, buffer and backfill, is important for the safe disposal of high-level radioactive waste. Three-dimensional computer simulations were carried out under different condition to examine the thermal and mechanical behavior of engineered barriers and rock mass. The research looked at five areas of importance, the effect of the swelling pressure, water content of buffer, density of compacted bentonite, emplacement type and the selection of failure criteria. The results highlighted the need to consider tensile stress in the outer shell of a canister due to thermal expansion of the canister and the swelling pressure from the buffer for a more reliable design of an underground repository system. In addition, an adequate failure criterion should be used for the buffer and backfill.