• 제목/요약/키워드: Thermal therapy

검색결과 209건 처리시간 0.022초

Special Issue for Biomedical Ultrasound: Towards Further Advances in Fundamentals and Applications by Comprehensive Reviews

  • Kim, Yong-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권3E호
    • /
    • pp.107-110
    • /
    • 2010
  • In this paper, the rationale and contents of the special issue of the Journal of the Acoustical Society of Korea regarding comprehensive reviews on past, present and future of biomedical ultrasound are described. Brief descriptions of invited articles are given, and efforts by all contributing authors are gratefully acknowledged.

온도범위에 따른 비침습적 자기공명 온도측정방법의 최적화 (Temperature-Range-Dependent Optimization of Noninvasive MR Thermometry Methods)

  • 김종민;;조영승;;김정희;이철현;오창현
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권6호
    • /
    • pp.241-250
    • /
    • 2015
  • Noninvasive temperature monitoring is feasible with Magnetic Resonance Imaging (MRI) based on temperature sensitive MR parameters such as $T_1$ and $T_2$ relaxation times, Proton Resonance Frequency shift (PRFs), diffusion, exchange process, magnetization transfer contrast, chemical exchange saturation transfer, etc. While the temperature monitoring is very useful to guide the thermal treatment such as RF hyperthermia or thermal ablation, the optimization of the MR thermometry method is essential because the range of temperature measurement depends on the choice of the measurement methods. Useful temperature range depends on the purpose of treatment methods, for example, $42^{\circ}C$ to $45^{\circ}C$ for RF hyperthermia and over $50^{\circ}C$ for thermal ablation. In this paper, MR thermometry methods using $T_1$ and $T_2$ relaxation times and PRFs-based MR thermometry are tried on a 3.0 T MRI system and their results are reported and compared. In addition, the scanning protocol and temperature calculation algorithms from $T_1$ and $T_2$ relaxation times and PRFs are optimized for the different temperature ranges for the purpose of RF hyperthermia and/or thermal ablation.

애주 연소 과정에서 발생하는 애주의 표면 및 중심부의 온도변화 특성 연구 (A Comparative Study of External & Central Temperature Characteristics during the Moxibustion Period)

  • 홍덕;권오상;김영진;김유리;김재효;안성훈;손인철
    • Korean Journal of Acupuncture
    • /
    • 제27권3호
    • /
    • pp.47-56
    • /
    • 2010
  • Objectives : The moxibustion is the method using the heat stimulation done by attached and burned a moxa on a healing point or acupuncture point with chemical stimulation of a resin made from burning them. The purpose of this study is to find the physical and thermal characteristics of moxibustion in order to standardize the moxa therapy method. Methods : In this study, the thermal changes were observed by means of a testo 845 device, which is an infra-red thermometer to measure the thermal changes. Results & Conclusions : 1. The thermal changes on the external surface of moxibustion did not depend on the weight of the moxa; the external surface temperature was about $500^{\circ}C$. 2. The central thermal changes depend on the weight of moxa; the central temperatures ranged from $500^{\circ}C$ to $700^{\circ}C$. 3. The burning duration of moxibustion depend on the weight of moxa but that of external surface temperature did not depend on the weight of moxa in high degree : about $400^{\circ}C$. 4. The integral values of central and external temperature curves were proportional to the weight of moxa; that is central temperature curves were higher than that of external.

피부 열전도 온도에 근거를 둔 거짓 뜸 개발 및 평가 연구 (Credibility of a Newly Developed Sham Moxibustion)

  • 장민기;윤은혜;정찬영;변혁;김은정;김경호;김갑성;이승덕
    • Journal of Acupuncture Research
    • /
    • 제27권1호
    • /
    • pp.117-127
    • /
    • 2010
  • Background : To demonstrate the efficacy of moxibustion therapy, randomized controled trials are required. But, clinical trials of moxibustion had limitations due to the absence of a sham moxibustion model for an appropriate placebo. Objectives : To develop a new sham moxibustion model based on the thermal characteristics of commercial indirect moxibustion, especially temperature, and to evaluate whether it could be applied in clinical trials. Methods : By applying heat insulation, we created a sham moxibustion device that was indistinguishable from a real one with the naked eye. It also stimulated heat but had inert remedial value. A clinical trial was performed on subjects to test double blinding. The subjects were randomly assigned into two groups, a treatment group and a sham group. Acupoint Zusanli($ST_{36}$) was used in each group for 3 times. A sham acupuncture credibility questionnaire was modified into a moxibustion credibility questionnaire and was filled out after treatment. Results : No major difference was detected in the subjects' baseline data. Most subjects and practitioners could not distinguish the sham moxibustion device from the real one. But, subjects who had experience of moxibustion therapy more likely to distinguish the sham moxibustion device from the real one than subjects who didn't have experience of moxibustion therapy. The treatment group showed a significant difference in the VAS(Visual Analog Scale) for intensity of sensation during treatment than that of the sham group. Conclusions : The sham moxibustion device in this study is proved sufficient and credible to be applied in investigations of the effect of moxibustion. But it is more appropriate for the people who don't have experience of moxibustion therapy.

냉.온열의 반복 자극이 전립선 내부의 온도 분포에 미치는 영향 (The Effects of Warm and Cold Stimulations on the Temperature Distribution in the Prostate)

  • 문우석;백병준;박복춘;김철생
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권6호
    • /
    • pp.467-475
    • /
    • 2002
  • 가온 프로브를 사용하여 직장을 통한 온열치교법이 비침습적 전립선치료의 한 방법으로 사용되고 있으나 직장벽 내에서의 과도한 온도에 의한 가열은 장점막의 손상을 입힐 뿐만 아니라 전립선 전체를 적절한 온도까지 가열하기가 어렵다고 알려져 있다. 따라서 전립선과 온열치료 시스템 사이에서 일어나는 열전달 메카니즘에 관한 보다 정확한 이해가 요구된다. 본 연구에서는 전립선 표면에 가해진 냉.온 자극이 전립선 내부의 온도 분포에 미치는 영향을 수치해석을 이용하여 검토하였다. 유한체적 프로그램인 "FLUENT"를 사용하여 비정상상태의 열전도방정식을 해석하여 전립선 내의 시간에 따른 온도분포를 고찰하고, 가열 및 냉각시간, 가열 및 냉각온도 등이 전립선 내부의 온도분포와 온열효과가 전달되는 영역을 규명하였다. 온열 치료법(40~45$^{\circ}C$)에 의해 온열효과가 나타나는 전립선의 내부 영역을 가시화하고, 가열/냉각의 반복 자극이 전립선의 온도분포에 미치는 영향을 조사한 결과 통상적인 온열 치료법에 의한 온열효과는 전립선의 낮은 열전도도의 영향에 의해 전립선의 일부 영역에만 도달되는 한계를 보였다. 가열/냉각의 냉.온 자극을 반복하면서 열적 자극효과를 고려한 냉.온 치료시스템을 개발하기 위하여 냉.온 자극 온도와 시간이 전립선 내부에 미치는 열전달 메카니즘을 고찰하여 원하는 자극주기와 전립선 내부 온도자극 정도를 설정하기 위한 유효한 자극패턴을 제시할 수 있는 기초자료를 획득하였다. 또한, 전립선 조직내부를 통과하는 혈액의 유동이 조직의 온도분포 및 열전달에 미치는 영향을 검토한 결과 냉온 자극 강도에 큰 영향을 미치지 않을 것으로 확인되었다. 이러한 결과는 냉온자극에 의한 전립선치료기의 자극프로브의 형상 설계와 가열에 의한 온열 효과 및 가열/냉각의 반복에 의한 열자극 효과를 동시에 얻을 수 있는 자극시스템을 개발하는 데에 유용하게 사용할 수 있으리라 사료된다.

Anti-allodynic Efficacy of NMDA Antagonist Peptide and Noradrenaline Alone and in Combination in Rodent Neuropathic Pain Model

  • Nasirinezhad, Farinaz;Hosseini, Marjan;Salari, Sajad
    • The Korean Journal of Pain
    • /
    • 제28권2호
    • /
    • pp.96-104
    • /
    • 2015
  • Background: The present experiment was conducted to identify the cooperative effect of serine histogranin (SHG) and noradrenaline in alleviating peripheral neuropathic pain. Methods: Chronic constriction injury of the right sciatic nerve was used to induce chronic neuropathic pain. For drug delivery, a PE10 tube was inserted into the subarachnoid space. Acetone drops and a $44^{\circ}C$ water bath were used to evaluate the cold and heat allodynia, respectively. Placing and grasping reflexes were used to assess the locomotor system. Results: SHG at 0.5 and $1{\mu}g$significantly (P < 0.05) decreased the thermal allodynia. The cold allodynia was also significantly reduced by intrathecal injections of 0.5 (P < 0.05) and $1{\mu}g$(P < 0.001) of SHG. $1{\mu}g$of noradrenaline, but not $0.5{\mu}g$, significantly alleviated the cold (P < 0.01) and thermal (P < 0.05) allodynia. The ameliorating effect of noradrenaline or SHG disappeared when the two compounds were administrated in equal concentrations. A significant difference (P < 0.01 in the acetone and P < 0.05 in the heat) was observed in the groups under equal doses of the two compounds, with a lower effectiveness of the combination therapy. Conclusions: Our findings suggest that the simultaneous administrations of noradrenaline and SHG do not result in synergistic analgesia, and combination therapy may not be a good approach to the treatment of chronic neuropathic pain syndrome.

방사모드에 따른 레이저 치료 효과 (A Effect of Photo Dynamic Therapy for LAZER Wave Mode)

  • 최덕수;임현수;이병구;네클라 커나르
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권4호
    • /
    • pp.134-139
    • /
    • 2016
  • US Food and Drug Administration (FDA) approved as a innovative cure for cancer, 1996. The effect is death of cancer cells through necrosis, apoptosis. Mainly the Continuous Wave mode (CW) use for PDT Laser. It sting, the question including itch, and etc. Reportedly, the increase of temperature with the perforated edema, ulcer, necrosis. The Thermal relaxation time and Oxygen recovery time is necessary. To give a normal oxygen recovery time of the cell, used Pulse mode. Progress, it was Burst Pulse mode when easing the thermal wake, the simplicity was secured, the PDT effect is good. Excepted in control group CW, Pulse, Burst pulse mode were incubated with various concentrations of 5-aminolevulinic acid hydrochloride (ALA-5). The tumor size reduction CW mode (44%), Pulse mode (48%), Burst pulse mode (53%) at 4 week after PDT with 0.3, 0.3, 0.3 mg/ml of ALA-5. After 4 hours, investigation of 100, 100, $100J/cm^2$ laser irradiation. The pulse mode was superior in expirimental data analysis. And it was the Burst pulse mode edge head of a family effect.

관절가동술이 만성요통 환자의 기동범위와 통증에 미치는 영향 (Effects of Joint Mobilization on The Range of Motion and Pain of Patient with Chronic Low Back Pain)

  • 이영화;권원안;김한수;배성수
    • 대한물리의학회지
    • /
    • 제2권2호
    • /
    • pp.113-124
    • /
    • 2007
  • Purpose : The purpose of this study was to investigate the effects of joint mobilization on the rang of motion and pain of patient with chronic low back pain. Methods : The subjects were consisted of thirty patients with chronic low back pain(19 females, 11 males ; mean aged 59.93) from 50 to 71. All subjects randomly assigned to the modalities treatment group, joint mobilization group. Modalities treatment group received hot pack used thermal therapy for 20minutes and ICT used electrical therapy for 15minutes, joint mobilization group received modalities treatment with sustained natural apophyseal glides(SNAGS) techniques of Mulligan for 10minutes per day and three times a week during 2 weeks period. Visual Analogue Scale(VAS) was used to measure subjective pain level. Remodified Schober test(RST) was used to measure range of motion of lumbar spine. All measurements of each patients were measured at pre-treatment and 2 weeks post-treatment. Results : The results of this study were summarized as follows : 1. VAS was joint mobilization group showed significantly decreased more than modalities treatment group (p<.05). 2. The lumbar flexion range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). 3. The lumbar extension range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). 4. The lumbar left lateral flexion range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). 5. The lumbar right lateral flexion range of motion was joint mobilization group showed significantly decreased more than modalities treatment group(p<.05). Conclusion : These data suggests that SNAGS of Mulligan is beneficial treatment for chronic low back pain.

  • PDF

초음파 적용시 전파매질에 따른 표면열과 심부열의 변화 (The Change of Superficial and Deep Heats in Ultrasound Application by Coupling Media)

  • 이영희;김진상
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.57-67
    • /
    • 2000
  • The purpose of this study was carried out in five rabbits of 3kg to investigate the change of superficial and deep heats in ultrasound application by coupling media. Temperature measured with thermistor needle at skin. subcutaneous, muscle in before coupling media application, after coupling media application. 2minutes. 5minutes, 7minutes, 10minutes. Coupling media was used gel, glycerin, distilled water. The data was analyzed using spss/pc+and t-test The results were as fallow : 1. With skin. gel was significant temperature change in 2minutes(p<.05). glycerin was significant temperature change in 2minutes(p<.05), 5minutes(p<.05), 7minutes(p<.01), 10minutes(p<.01). distilled water was significant temperature change in post coupling media(p<.05), 2minutes(p<.01). 5minutes(p<.05). 7minutes(p<.01). 10minutes(p<.01). With subcutaneous. gel was no temperature change. glycerin was significant temperature change in 2minutes(p<.05), 5minutes(p<.05), 10minutes(p<.01). distilled water was no temperature change. With muscle. gel was no temperature change. glycerin was significant temperature change in 2minutes(p<.05). 5minutes(p<.05). 7minutes(p<.05). 10minutes( p<.05). distilled water was significant temperature change in 10minutes(p<.05). 2. Superficial heats of skin and subcutaneous was higher temperature change than Deep heats of muscle. 3. Gel. glycerin. distilled Water required minimum treatment 10minutes fur thermal effect. 4. Gel was low temperature change superficial and deep heats. and glycerin was high temperature change superficial and deep heats. This results show that gel is high transmissiveness in the coupling media and glycerin is low transmissiveness in the coupling media.

  • PDF