Modeling of a Greenhouse Equipped with Latent Heat Storage System (잠열축열 장치를 갖춘 온실의 난방 열 특성 예측모형개발)

  • Ro, J.G.;Song, H.K.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.3
    • /
    • pp.51-60
    • /
    • 2001
  • A greenhouse equipped with latent heat storage system was built to obtain various thermal properties, such as greenhouse air temperature, soil surface temperature, energy flow in latent heat storage, etc., which could be used in validation of greenhouse numerical model to be developed in this study. This numerical model expressed with Newton-Raphson method was programed by C-language and utilized to simulate greenhouse thermal behavior. Greenhouse air temperature and soil surface temperature predicted by the greenhouse model developed in this study were very close to the measured data obtained through almost 3 years of experiment. Therefore, it is concluded that the greenhouse model developed and verified by measured data could be utilized for simulating various thermal behaviors of greenhouses equipped with latent heat storage system to be used for energy saving purposes.

  • PDF

Numerical Study on Thermal Stratification of the Aspect ratio of Solar Thermal Storage Tank (태양열 축열조의 종횡비에 따른 열성층화 수치해석 연구)

  • Joo, Hong-Jin;Kim, Jung-Bae;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.178-183
    • /
    • 2008
  • The purpose of this study is to compare the effect on the thermal stratification under various aspect ratios in the solar storage tank using FLUENT. Numerical calculations of three designs with different aspect ratio were carried out to show the behaviour of stratification in a solar storage tank. The calculation results show that the thermal stratification of the 2.5:1 aspect ratio solar storage tank can be 6.22% higher then that of the 1.5:1 aspect ratio solar storage tank and 2.68% higher then that of the 2:1 aspect ratio solar storage tank.

  • PDF

An Effect of Insulated Raft on Longterm Hot Water Storage (Insulated Raft가 장기온수저장에 미치는 영향)

  • Pak, Ee-Tong;Cho, Woon
    • Solar Energy
    • /
    • v.17 no.1
    • /
    • pp.79-91
    • /
    • 1997
  • Thermal energy storage system used a storage tank is a reasonable method to solve energy problem. In thermal energy storage system, energy collected from many types of heat source is stored in a storage tank and then supply to load at the time is in demand. In this study, flow characteristics and storage efficiency were analysed by using a insulated raft in longterm hot water storage system. From the experiment it is found that insulated raft has a important role in longterm hot water storage system and storage efficiency can be obtained to 96% using inletport type and insulated raft together.

  • PDF

Mathematical Simulation on Thermal Performance of Packed Bed Solar Energy Storage System (Packed Bed 태양에너지 저장시스템의 열성능에 관한 수학적 시뮬레이션)

  • KUMAR, ANIL;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.331-338
    • /
    • 2015
  • Solar air heaters (SAHs) are simple in design and widely used for solar energy collection devices, and a packed bed is one of typical solar energy storage systems of thermal energy captured by SAHs. This paper presents mathematical modeling and simulation on the thermal performance of various packed bed energy storage systems. A MATLAB program is used to estimate the thermal efficiency of packed bed SAH. Among the various packed bed energy storage systems considered, the wire mesh screen packed bed SAH shows the best thermal efficiency over the entire range of design conditions. The maximum of thermal efficiency of packed bed SAH with wire mesh screen matrices has been found to be 0.794 for Re=2000 - 20000 and ${\Delta}T/I=0.002-0.02$.

A Sensitivity Analysis of Design Factors of Air-Conditioning System with Slab Thermal Storage (슬래브축열 시스템 설계인자의 감도해석)

  • Jung, Jae-Hoon
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.590-595
    • /
    • 2008
  • In this paper, the sensitivity analysis was examined about the main factors that compose an air-conditioning system with slab thermal storage by using the analytic solution. Those factors are the insulation performance of floor slab surface, the slab thickness, the heat capacity of floor slab, the air change rate, and the insulation performance of the wall. The slab thickness and heat capacity of floor slab that minimize heating loads was gained by sensitivity analysis. It is became clear that the insulation performance of slab surface, high airtightness and high heat insulation are important design factors in air conditioning system with slab thermal storage.

  • PDF

A Study on Daily Operation Model for Total Energy System Including Building Cogeneration, Ice Storage, Thermal and Electrical Storage Facilities (건물용 열병합발전 설비를 중심으로 한 종합 에너지 시스템의 최적 일간 운전모형 수립에 관한 연구)

  • Park, Jong-Seong;Chang, Seung-Chan;Shim, Keun-Bo;Kim, Jung-Hoon;Ko, Yo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.724-726
    • /
    • 1996
  • In this paper, we propose an optimal daily operation model for the total energy system which includes cogeneration, thermal storage and electrical charger and ice storage facilities. Storing and utilizing the surplus thermal and electrical energy, the daily operation cost could be reduced and more efficient use of thermal energy could be achieved. The ice storage cooling system has a merit of reduce the electricity cost by time of day rate(peak/off-peak). And also, refrigerator can be down sized compare to the other cooling system From this model, operation costs of the sample cogeneration system with/without auxiliary facilities are obtained and compared to each other. In case study, the sensitivity of operating cost is simulated according to the variation of cogeneration production cost, electricity rate, etc.

  • PDF

Thermal Stress Analysis of the Support System in Cryogenic Liquid Hydrogen Storage Tank (극저온 액체수소 저장탱크 지지시스템의 열응력 해석)

  • Park, Dong-Huen;Yun, Sang-Kook;Lee, Jung-Hyan;Jo, Won-Il;Baek, Young-Sun
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.239-245
    • /
    • 2005
  • The reduction of heat transfer rate to the stored liquid hydrogen from outside condition is extremely important to keep the liquid hydrogen longer. In this paper the highly efficient support system for the liquid hydrogen storage vessel was newly developed and analysed. The support system was composed of a spherical ball in the center of supporter to reduce the heat transfer area, with its above and below supporting blocks which are the SUS and PTFE blocks inserted in the SUS tube. The heat transfer rate and temperature distribution of the support system were evaluated by FLUENT, and the thermal stress and strain were estimated by ANSYS software. The results showed that the heat transfer rate from outer vessel to inner one was extremely decreased compared with the common method which is simply SUS tubes inserted between inner and outer tanks. The thermal stress and strain were obtained well below the limited values. As a result, it was the most efficient support system of storage vessel for liquid hydrogen and most cryogenic fluids.

  • PDF

Experiment of Characteristic on the Charge and Discharge of Cold for In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열 시스템의 축방냉 특성)

  • Jang, Y.S.;Choi, I.S.;Moon, C.G.;Chun, S.H.;Kim, J.D.;Yoon, J.I.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.268-273
    • /
    • 2001
  • A fundamental study on the harvest-type ice storage system applied ice making method in-water and its temperature characteristics in ice storage system was performed experimentally of the charge and discharge of cold. This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks.

  • PDF

Design of a renewable energy system with battery and power-to-methanol unit

  • Andika, Riezqa;Kim, Young;Yun, Choa Mun;Yoon, Seok Ho;Lee, Moonyong
    • Korean Journal of Chemical Engineering
    • /
    • v.36 no.1
    • /
    • pp.12-20
    • /
    • 2019
  • An energy storage system consisting of a battery and a power-to-methanol (PtM) unit was investigated to develop an energy storage system for renewable energy systems. A nonlinear programming model was established to optimize the energy storage system. The optimal installation capacities of the battery and power-to-methanol units were determined to minimize the cost of the energy system. The cost from a renewable energy system was assessed for four configurations, with or without energy storage units, of the battery and the power-to-methanol unit. The proposed model was applied to the modified electricity supply and demand based on published data. The results show that value-adding units, such as PtM, need be included to build a stable renewable energy system. This work will significantly contribute to the advancement of electricity supply and demand management and to the establishment of a nationwide policy for renewable energy storage.

Winter Season Performance Characteristics of Raw Water-Source Heat Pump System with a Thermal Storage Tank (원수열원 히트펌프 축열시스템의 동절기 성능분석)

  • Cho, Yong;Lee, Dong Keun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.202-202
    • /
    • 2011
  • Performance of the raw water-source heat pump system with a thermal storage tank has been analyzed in winter season. The raw water is transferred through the multi-regional water supply system from Han river. Raw water is large temperature difference resource compared with groundwater. Although the raw water temperature drops to $0.6^{\circ}C$ due to the heavy snowfall and the severe cold in late January and early February, 2010, the system has been normally operated without any trouble this winter. The unit COP and system COP considered all pump power consumption were estimated based on the second-by-second data of the all sensors. The monthly averaged unit COP and system COP are 3.37 and 2.76 respectively with $1.4^{\circ}C$ of raw water in January, 3.55 and 2.89 with $1.6^{\circ}C$ raw water in February, 3.82 and 3.15 with $5.4^{\circ}C$ raw water in March. The performance of the system are increased with raw water temperature, and the COPs are higher than the water-to-air heat pump system using relatively high temperature raw water from Daecheong reservoir because the water-to-water system was operated on the full load condition and was stopped when the thermal storage tank was full of the high temperature water.

  • PDF