• 제목/요약/키워드: Thermal performance factor

검색결과 315건 처리시간 0.036초

Effect of thermal conductivity degradation on the behavior of high burnup $UO_2$ fuel

  • Lee, Byung-Ho;Koo, Yang-Hyun;Sohn, Dong-Seong
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(3)
    • /
    • pp.265-270
    • /
    • 1996
  • The temperature distribution in the pellet was obtained from beginning the general heat conduction equation. The thermal conductivity of pellet used the SIMFUEL data that made clear the effect of burnup on the thermal conductivity degradation. Since the pellet rim acts as the thermal barrier to heat flow. the pellet was subdivided into several rings in which the outer ring was adjusted to play almost the same role as the rim. The local burup in each ring except the outer ring was calculated from the power depression factor based on FASER results. whereas the rim burnup at the outer ring was achieved by the pellet averaged burnup based on the empirical relation. The rim changed to the equivalent Xe film so the predicted temperature shooed the thermal jump across the rim. The observed temperature profiles depended on linear heat generation rate. fuel burnup. and power depression factor. The thermal conductivity degradation modelling can be applied to the fuel performance code to high burnup fuel,

  • PDF

인공위성 열해석을 위한 복사형상계수 계산기법의 병렬화 및 성능향상 기법 연구 (Studies of Parallelism and Performance Enhancements of Computing View Factor for Satellite Thermal Analysis)

  • 김민기
    • 한국항공우주학회지
    • /
    • 제43권12호
    • /
    • pp.1079-1088
    • /
    • 2015
  • 본 연구는 한국항공우주연구원에서 개발한 위성종합설계 SW 내의 복사계수 계산 프로그램의 병렬화 및 성능향상에 대해 논의한다. 복사계수는 복사열전달이 포함된 인공위성의 열해석을 수행하기 위한 필수적인 전초 단계로서 그 자체적인 계산량 또한 상당하다. 특히 위성 궤도상 시간에 따라 태양전지판과 본체의 상대변위가 변하기에 시간 별 독립적인 복사계수의 계산이 필요하다. 본 논문은 복사형상계수 병렬화 방법과 그 성능, KD-Tree 기반 차폐 탐색 알고리즘 및 태양전지판과 본체의 상대변위 변화에 따른 부분 복사형상계수 행렬 갱신이라고 지칭하는 계산량 저감 기법에 대해 논한다.

Dish형 태양열 집광시스템 실증연구를 위한 집열성능 특성 분석 (A Characteristic Analysis on the Thermal Performance of the Dish Type Solar Concentrating System)

  • 강명철;강용혁;윤환기;유성연
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.7-12
    • /
    • 2006
  • The dish type solar thermal concentrating system can collect the solar energy above $800^{\circ}C$. It has a concentration ratio of 800 and total reflector area of $49m^2$. To operate solar receivers at high temperature, the optimum aperture size is obtained from a comparison between maximizing absorbed energy and minimizing thermal losses. The system efficiency is defined as the absorbed energy by working fluid in receiver divided by the energy coming from the concentrator. We find that system efficiency is stable in case of flow rate of above 6lpm. The system efficiency are 64.9% and 65.7% in flow rate of 6lpm and 8lpm, respectively. The thermal performance showed that the maximum efficiency and the factor of thermal loss in flow rate of 8lpm are 68% and 0.0508.

자료처리/저장장치 방열판의 View Factor 분석 (Analysis on the View Factor of Data Storage and Handling Units's Radiators)

  • 황인영;신소민
    • 한국항공우주학회지
    • /
    • 제45권8호
    • /
    • pp.678-685
    • /
    • 2017
  • 지구관측위성에 탑재되는 자료처리/저장장치 방열판은 장비의 주기적인 고발열, 배치, 장착성 등 설계 특성으로 인해 쉴드가 장착된 홈 형태를 갖는다. 홈 형태 방열판의 영향성과 쉴드 방열판의 열성능을 확인하기 위해, 평판 방열판을 기준으로 홈 형태의 방열판과 쉴드 방열판을 비교하여 열진공 시험을 실시하였다. 시험결과를 바탕으로 view factor에 의한 열교환과 방열판의 온도를 이론해석적으로 분석하여 열 설계 성능비교의 타당성을 입증하였다.

The Analysis of Heat Transfer through the Multi-layered Wall of the Insulating Package

  • Choi, Seung-Jin
    • 한국포장학회지
    • /
    • 제12권1호
    • /
    • pp.45-53
    • /
    • 2006
  • Thermal insulation is used in a variety of applications to protect temperature sensitive products from thermal damage. Several factors affect the performance of insulation packages. Among these factors, the thermal resistance of the insulating wall is the most important factor to determine the performance of the insulating package. In many cases, insulating wall consists of multi-layered structure and the heat transfer through this structure is a very complex process. In this study, an one-dimensional mathematical model, which includes all of the heat transfer principles covering conduction, convection and radiation in multi-layered structure, were developed. Based on this model, several heat transfer phenomena occurred in the air space between the layer of the insulating wall were investigated. From the simulation results, it was observed that the heat transfer through the air space between the layer were dominated by conduction and radiation and the low emissivity of the surface of each solid layer of the wall can dramatically increase the thermal resistance of the wall. For practical use, an equation was derived for the calculation of the thermal resistance of a multi-layered wall.

  • PDF

2.5 GHz ZnO-based FBAR Devices and Their Thermal Improvements

  • Mai, Linh;Pham, Van-Su;Yoon, Gi-Wan
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.59-62
    • /
    • 2008
  • In this paper, we study ZnO-based a film bulk acoustic resonator (FBAR) using a multi-layered Bragg reflector. We insert chromium adhesion layers of 0.03 mm-thick to the Bragg reflector and improve the performance using thermal treatments. At operating frequency about 2.5 GHz, excellent resonance characteristics are observed in terms of good return loss and high quality factor.

  • PDF

CFD를 이용한 전동기 냉각성능 개선에 관한 연구 (A Study on Improvement of Electic Motor Thermal Performance Using CFD)

  • 양판석;이호준;전원봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.261-265
    • /
    • 2003
  • As motor performance enhancement by improving electric design has reached its limit and downsizing issue has risen, the importance of thermal design is increasing. In this study, the flow and temperature distribution were reviewed with the help of CFD analysis and this result was compared with the experimental results. Furthermore, parametric analysis with thermal design structure showed that axial duct width but fan capacity is a critical factor to lower the hot spot temperature in electric motor.

  • PDF

슬래브축열 시스템 설계인자의 감도해석 (A Sensitivity Analysis of Design Factors of Air-Conditioning System with Slab Thermal Storage)

  • 정재훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.590-595
    • /
    • 2008
  • In this paper, the sensitivity analysis was examined about the main factors that compose an air-conditioning system with slab thermal storage by using the analytic solution. Those factors are the insulation performance of floor slab surface, the slab thickness, the heat capacity of floor slab, the air change rate, and the insulation performance of the wall. The slab thickness and heat capacity of floor slab that minimize heating loads was gained by sensitivity analysis. It is became clear that the insulation performance of slab surface, high airtightness and high heat insulation are important design factors in air conditioning system with slab thermal storage.

  • PDF

주방환기용 직교류 알루미늄 열교환기의 성능해석 및 시험 (Performance Analysis and Testing of a Cross-Flow Aluminum Heat Exchanger for Kitchen Ventilation)

  • 김내현;조진표;한성필;최준영
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.193-201
    • /
    • 2006
  • Thermal performance model was developed for a cross-flow aluminum heat exchanger with relatively short passage. Appropriate heat transfer coefficient and friction factor equations for laminar channel flow were obtained considering developing regions. The heat exchanger was analyzed using the unmixed cross-flow ${\epsilon}$-NTU relationship considering leak-age between streams. Thermal contact between corrugations and plates was also considered. Tests were separately conducted for two samples - one made of non-treated aluminum sheets, and the other made of varnish-treated ones. The samples were made by stacking corrugations and plates one after another. The model adequately predicted the thermal performance and pressure drop of the non-treated heat exchanger. The thermal performance of the varnish-treated one was $7{\sim}12%$ overpredicted, and the pressure drop of the varnished-treated heat exchanger was $5{\sim}15%$ underpredicted. The air leakage ratio of the non-treated heat exchanger was $23{\sim}26%$. The ratio decreased to less than $10%$ with the varnish treatment.

BATCH형 자연형 태양열 온수급탕 시스템의 열적 성능에 관한 실험적 연구 (Experimental Study for Thermal Performance of Batch Type Passive Solar Hot Water System)

  • 강용혁;조일식;윤환기;오정무
    • 태양에너지
    • /
    • 제7권1호
    • /
    • pp.3-13
    • /
    • 1987
  • A batch type passive solar water systems, which perform the dual function of absorbing the solar energy and storing the heated water, have been designed and fabricated for the purpose of side-by-side testing at KIER. The test models included an A, B and C type batch systems which were classified according to the design of box and arrangement of tanks. The year-round performance tests show that B type batch system taken the step-wise tank arrangement indicates 55.7% yearly-average collection efficiency factor and 61% yearly-average maximum collection efficiency factor. Computer-aided-experimental results show that the sufficient hot water can be obtained in the early morning if the glazing is supplemented by a reflector/insulation cover. The thermal performance equation has been developed for the prediction of hourly variation of the water temperature in tank.

  • PDF