• Title/Summary/Keyword: Thermal model

Search Result 4,377, Processing Time 0.032 seconds

Development of an Optimization Technique of CETOP-D Inlet Flow Factor for Reactor Core Thermal Margin Improvement (원자로심의 열적여유도 증대를 위한CETOP-D의 입구유량인자 최적화 기법 개발)

  • Hong, Sung-Deok;Lim, Jong-Seon;Yoo, Yeon-Jong;Kwon, Jung-Tack;Park, Jong-Ryul
    • Nuclear Engineering and Technology
    • /
    • v.27 no.4
    • /
    • pp.562-570
    • /
    • 1995
  • The recent ABB/CE(Asea Brown Boveri Combustion Engineering) type pressurized oater reactor-s have the on-line monitoring system, i.e., the COLSS(core operating limit supervisory system), to prevent the specified acceptable fuel design limits from being violated during normal operation and anticipated operational occurrences. One of the main functions of COLSS is the on-line monitoring of the DNB(departure from nucleate boiling) overpower margin by calculating the MDNBR(mini-mum DNB ratio) for the measured operating condition at every second. The CETOP-D model, used in the MDNBR calculation of COLSS, is benchmarked conservatively against the TORC mod-el using an inlet flow factor of hot assembly in CETOP-D as an adjustment factor for TORC. In this study, a technique to optimize the CETOP-D inlet flow factor has been developed by elim-inating the excessive conservatism in the ABB/CE's. A correlation is introduced to account for the actual variation of the CETOP-D inlet flow factor within the core operating limits. This technique was applied to the core operating range of the YongGwang Units 3&4 Cycle 1, which results in the increase of 2% in the DNB overpower margin at the normal operating condition, compared with that from the ABB/CE method.

  • PDF

Estimation of Surplus Solar Energy in Greenhouse Based on Region (지역별 온실내의 잉여 태양에너지 산정)

  • Yoon, Yong-Cheol;Im, Jae-Un;Kim, Hyeon-Tae;Kim, Young-Joo;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.45 no.4
    • /
    • pp.135-141
    • /
    • 2011
  • This research was conducted to provide basic data of surplus heat for designing solar heat-storage systems. The surplus heat is defined as the heat exhausted by forced ventilations from the greenhouses to control the greenhouse temperature within setting limits. Various simulations were performed to compare the differences of thermal behaviors among greenhouse types as well as among several domestic areas by using pseudo-TMY (Typical Meteorological Year) data manipulated based both on the weather data supplied from Korean Meteorological Administration and the TMY data supplied from The Korean Solar Energy Society. Additional analyses were carried out to examine the required heating energy together with some others such as the energy balances in greenhouses to be considered. The results of those researches are summarized as follows. Regional surplus solar heats for the nine regions with 4-type were analyzed. The results showed that the ratio of surplus solar energy compared to heating energy was the highest in Jeju (about 212.0~228.0%) for each greenhouse type. And followed by Busan, Kwangju, Jinju, Daegu, Daejeon, Jeonju, Suwon and Daekwanryung. And irrespective of greenhouse types, surplus solar energy alone could cover up nearly all of the required supplemental heating energy except for a few areas.

Analysis of Surplus Solar Energy in Greenhouse Based on Setting Temperature (설정온도별 온실내 잉여 태양에너지 분석)

  • Yoon, Yong-Cheol;Kown, Sun-Ju;Kim, Hyeon-Tae;kim, Young-Joo;Suh, Won-Myung
    • Journal of agriculture & life science
    • /
    • v.46 no.1
    • /
    • pp.195-206
    • /
    • 2012
  • This study is about an analysis of surplus solar energy by important greenhouse types as well as setting temperature different by using Typical Meteorological Year data which was secured in order to provide basic data for designing an optimum thermal storage system to accumulate surplus solar energy generating in greenhouses during the daytime. Depending on the setting temperatures of $15{\sim}19^{\circ}C$ for greenhouse heating during day and night, surplus heat amounts were varied at the rate of about $0.2{\sim}6.9%/4^{\circ}C$ with some variations according to the greenhouse types and regions. On the other hand, the variations of supplemental heat requirements were about $29.7{\sim}50.0%/4^{\circ}C$. Depending on the setting temperatures for greenhouse ventilations(low $25{\sim}29^{\circ}C$ and high $27{\sim}31^{\circ}C$), surplus heat amounts were varied at the rate of about $-9.9{\sim}-35.6%/4^{\circ}C$ in auto-type greenhouse. But in single-type greenhouses, they were about $-5.1{\sim}-13.4%/4^{\circ}C$. There were not significant changes in supplemental heat amounts depending on setting temperatures of ventilation for both greenhouse types and regions.

The Age of the Earth: Reappraisal (지구의 나이: 재평가)

  • Kwon, Sung-Tack
    • The Journal of the Petrological Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.273-277
    • /
    • 2014
  • This paper presents a brief historical review of various attempts to estimate the age of the Earth, and reappraises the study of Patterson (1956) which revealed for the first time that the age of the Earth is $4550{\pm}70Ma$ by measuring Pb isotope ratios of several meteorites and a marine sediment. The standard model for the planetary formation of early solar system is: formation of solid particles condensed from the cooling of hot nebular gas -> formation of planet-sized bodies by accretion of those solid particles. The Moon is supposed to have formed from the accretion of the relicts produced by the collision of proto-Earth with Mars-sized body. It is not easy to pinpoint the age of the Earth, considering the series of events related to the formation of the Earth. So, I propose that the collision age as that of the Earth, since the present status of the Earth is thought to be the direct product of the collision. According to the previous studies, the collision age can be broadly constrained between the age ($4567.30{\pm}0.16Ma$) of the earliest condensates (CAI, calcium-aluminum rich inclusion) of the nebula gas, i.e., the age of the solar system, and the oldest age ($4,456{\pm}40Ma$) among rocks and minerals of the Earth and the Moon. We need more precise estimation of the collision age, since it is important in estimating time scale for the formation of planet-size body and in revealing thermal evolution of magma oceans of the Earth and the Moon presumably developed right after the collision.

Stability of the enzyme-modified starch-based hydrogel model premix with curcumin during in vitro digestion (효소변형 전분기반 하이드로젤 모델 프리믹스 내 탑재된 커큐민의 소화과정 중 안정성)

  • Kang, Jihyun;Rho, Shin-Joung;Lee, Jiyoung;Kim, Yong-Ro
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.4
    • /
    • pp.365-374
    • /
    • 2021
  • In this study, the effect of enzyme-modified starch used in the preparation of filled hydrogel powder loaded with curcumin (FHP) on redispersibility, thermal and UV stability, and curcumin retention during in vitro digestion was investigated. FHP maintained stability without layer separation when redispersed and showed more stability against UVB than the emulsion powder (EMP). There was no significant difference in the chemical stability of curcumin between rice starch-based filled hydrogel powder (RS-FHP) and enzyme-modified starch-based filled hydrogel powder (GS-FHP). However, the gel matrix of GS-FHP maintained greater stability of lipid droplets in the stomach compared to RS-FHP, thereby improving the retention rate of curcumin after in vitro digestion. GS-FHP could be used as a novel material for developing premixes that require stable formulation and maintenance of functional substances, as it can increase the dispersion stability and retention rate of functional substances after digestion.

An Experimental Study for the Effect of Operating Condition of the Air Handling Unit on the Performance of Humidifying Elements (공조기 운전 조건이 가습 소자의 성능에 미치는 영향에 대한 실험 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.326-331
    • /
    • 2018
  • Evaporative humidification using a humidifying element is used widely for the humidification of a building or a data center. The performance of a humidifying element is commonly expressed as the humidification efficiency, which is assumed to be independent of the air temperature or humidity. To verify this assumption, a series of tests were conducted under two air conditions - data center ($25^{\circ}C$ DBT, $15^{\circ}C$ WBT) and commercial building ($35^{\circ}C$ DBT, $21^{\circ}C$ WBT) - using humidifying elements made from cellulose/PET and changing the frontal air velocity from 1.0 m/s to 4.5 m/s. Three samples having a 100 mm, 200 mm, or 300 mm depth were tested. The results showed that the humidification efficiency is dependent on the air condition. Indeed, even dehumidification occurred at the inlet of the humidifying element at the air condition of commercial building. This suggests that a proper thermal model should account for the inlet area, where the amount of moisture transfer may be different from the other part of the humidification element. As the depth of the element increased from 100 mm to 200 mm, the humidification efficiency increased by 29%. With further increases to 300 mm, it increased by 42%. On the other hand, the pressure drop also increased by 47% and 86%.

Fabrication and Electrical Property Analysis of [(Ni0.3Mn0.7)1-xCux]3O4 Thin Films for Microbolometer Applications (마이크로볼로미터용 [(Ni0.3Mn0.7)1-xCux]3O4 박막의 제작 및 전기적 특성 분석)

  • Choi, Yong Ho;Jeong, Young Hun;Yun, Ji Sun;Paik, Jong Hoo;Hong, Youn Woo;Cho, Jeong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.41-46
    • /
    • 2019
  • In order to develop novel thermal imaging materials for microbolometer applications, $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ ($0.18{\leq}x{\leq}0.26$) thin films were fabricated using metal-organic decomposition. Effects of Cu content on the electrical properties of the annealed films were investigated. Spinel thin films with a thickness of approximately 100 nm were obtained from the $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ films annealed at $380^{\circ}C$ for five hours. The resistivity (${\rho}$) of the annealed films was analyzed with respect to the small polaron hopping model. Based on the $Mn^{3+}/Mn^{4+}$ ratio values obtained through x-ray photoelectron spectroscopy analysis, the hopping mechanism between $Mn^{3+}$ and $Mn^{4+}$ cations discussed in the proposed study. The effects of $Cu^+$ and $Cu^{2+}$ cations on the hopping mechanism is also discussed. Obtained results indicate that $[(Ni_{0.3}Mn_{0.7})_{1-x}Cu_x]_3O_4$ thin films with low temperature annealing and superior electrical properties (${\rho}{\leq}54.83{\Omega}{\cdot}cm$, temperature coefficient of resistance > -2.62%/K) can be effectively employed in applications involving complementary metal-oxide semiconductor (CMOS) integrated microbolometer devices.

Nickel Catalysts Supported on Ash-Free Coal for Steam Reforming of Toluene (무회분탄에 분산된 니켈 촉매의 톨루엔 수증기 개질)

  • PRISCILLA, LIA;KIM, SOOHYUN;YOO, JIHO;CHOI, HOKYUNG;RHIM, YOUNGJOON;LIM, JEONGHWAN;KIM, SANGDO;CHUN, DONGHYUK;LEE, SIHYUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.6
    • /
    • pp.559-569
    • /
    • 2018
  • Catalytic supports made of carbon have many advantages, such as high coking resistance, tailorable pore and surface structures, and ease of recycling of waste catalysts. Moreover, they do not require pre-reduction. In this study, ash-free coal (AFC) was obtained by the thermal extraction of carbonaceous components from raw coal and its performance as a carbon catalytic support was compared with that of well-known activated carbon (AC). Nickel was dispersed on the carbon supports and the resulting catalysts were applied to the steam reforming of toluene (SRT), a model compound of biomass tar. Interestingly, nickel catalysts dispersed on AFC, which has a very small surface area (${\sim}0.13m^2/g$), showed higher activity than those dispersed on AC, which has a large surface area ($1,173A/cm^2$). X-ray diffraction (XRD) analysis showed that the particle size of nickel deposited on AFC was smaller than that deposited on AC, with the average values on AFC ${\approx}11nm$ and on AC ${\approx}23nm$. This proved that heteroatomic functional groups in AFC, such as carboxyls, can provide ion-exchange or adsorption sites for the nano-scale dispersion of nickel. In addition, the pore structure, surface morphology, chemical composition, and chemical state of the prepared catalysts were analyzed using Brunauer-Emmett-Taylor (BET) analysis, transmission electron microscopy (TEM), scanning electron microscopy (SEM), x-ray diffraction (XRD), Fourier-transform infrared (FT-IR) spectroscopy, and temperature-programmed reduction (TPR).

A Study on the Element Technologies in Flame Arrester of End Line (선박의 엔드라인 폭연방지기의 요소기술에 관한 연구)

  • Pham, Minh-Ngoc;Choi, Min-Seon;Kim, Bu-Gi
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.468-475
    • /
    • 2019
  • An end-line flame arrester allows free venting in combination with flame protection for vertical vent applications. End-line flame arresters are employed in various fields, especially in shipping. In flame arresters, springs are essential parts because the spring load and the spring's elasticity determine the hood opening moment. In addition, the spring has to work under a high-temperature condition because of the burning gas flame. Therefore, it is necessary to analyze the mechanical load and elasticity of the spring when the flame starts to appear. Based on simulations of the working process of a specific end-line flame arrester, a thermal and structural analysis of the spring is performed. A three-dimensional model of a burned spring is built using computational fluid dynamics (CFD) simulation. Results of the CFD analysis are input into a finite element method simulation to analyze the spring structure. The research team focused on three cases of spring loads: 43, 93, and 56 kg, correspondingly, at 150 mm of spring deflection. Consequently, the spring load was reduced by 10 kg after 5 min under a $1,000^{\circ}C$ heat condition. The simulation results can be used to predict and estimate the spring's load and elasticity at the burning time variation. Moreover, the obtained outcome can provide the industry with references to optimize the design of the spring as well as that of the flame arrester.

Analysis and Utilization Strategies of Ventilation Corridor Characteristics in Jeon-ju Area (전주지역의 바람길 특성 분석 및 활용 방안)

  • Eum, Jeong-Hee
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.3
    • /
    • pp.366-374
    • /
    • 2019
  • This study aims to analyze the characteristics of ventilation corridor and propose its utilization strategies in Jeonju city in order to discuss how to utilize urban ventilation corridors as a planning factor for reducing heat wave impact and fine particle pollution. For these purposes, cold air characteristics such as cold air flow and height of cold air in Jeonju area located in the Honam Jeongmaek were analyzed and major ventilation corridors were specified. Based on them, we proposed mountain management strategies for securing and utilizing ventilation corridors. We used KALM (Kaltluftabflussmodell), a cold air simulation model developed in Germany and identified both the cold air flow and the height of cold air layer generated during 6 hours at night. As a result, the cold air flow generated in the forests located in the northeast and east sides of the Jeonju city became clear and the height of cold air layer increased in the valley terrain and farmland areas with time. In particular, Jeonju City has an ideal structure of urban ventilation corridor. Based on the results, the area where the cold air generation is active was designated as the 'cold air conservation area', and the area requiring the management for the good cold air flow was as the 'cold air management area'. This study is expected to be used as basic data of policy making and research for reducing heat wave impact and fine particle pollution such as climate change adaptation policy and urban forest plans for ventilation corridor composition.