• 제목/요약/키워드: Thermal load distribution

검색결과 254건 처리시간 0.024초

Thermal post-buckling behavior of imperfect graphene platelets reinforced metal foams plates resting on nonlinear elastic foundations

  • Yin-Ping Li;Gui-Lin She;Lei-Lei Gan;H.B. Liu
    • Earthquakes and Structures
    • /
    • 제26권4호
    • /
    • pp.251-259
    • /
    • 2024
  • In this paper, the thermal post-buckling behavior of graphene platelets reinforced metal foams (GPLRMFs) plate with initial geometric imperfections on nonlinear elastic foundations are studied. First, the governing equation is derived based on the first-order shear deformation theory (FSDT) of plate. To obtain a single equation that only contains deflection, the Galerkin principle is employed to solve the governing equation. Subsequently, a comparative analysis was conducted with existing literature, thereby verifying the correctness and reliability of this paper. Finally, considering three GPLs distribution types (GPL-A, GPL-B, and GPL-C) of plates, the effects of initial geometric imperfections, foam distribution types, foam coefficients, GPLs weight fraction, temperature changes, and elastic foundation stiffness on the thermal post-buckling characteristics of the plates were investigated. The results show that the GPL-A distribution pattern exhibits the best buckling resistance. And with the foam coefficient (GPLs weight fraction, elastic foundation stiffness) increases, the deflection change of the plate under thermal load becomes smaller. On the contrary, when the initial geometric imperfection (temperature change) increases, the thermal buckling deflection increases. According to the current research situation, the results of this article can play an important role in the thermal stability analysis of GPLRMFs plates.

Geometrical imperfection and thermal effects on nonlinear stability of microbeams made of graphene-reinforced nano-composites

  • Fenjan, Raad M.;Faleh, Nadhim M.;Ahmed, Ridha A.
    • Advances in nano research
    • /
    • 제9권3호
    • /
    • pp.147-156
    • /
    • 2020
  • This research is related to nonlinear stability analysis of advanced microbeams reinforced by Graphene Platelets (GPLs) considering generic geometrical imperfections and thermal loading effect. Uniform, linear and nonlinear distributions of GPLs in transverse direction have been considered. Imperfection sensitivity of post-bucking behaviors of the microbeam to different kinds of geometric imperfections have been examined. Geometric imperfection is first considered to be identical as the first buckling mode, then a generic function is employed to consider sine-type, local-type and global-type imperfectness. Modified couple stress theory is adopted to incorporate size-dependent behaviors of the beam at micro scale. The post-buckling problem is solved analytically to derive load-amplitude curves. It is shown that post-buckling behavior of microbeam is dependent on the type geometric imperfection and its magnitude. Also, post-buckling load can be enhanced by adding more GPLs or selecting a suitable distribution for GPLs.

Thermal buckling behaviour of shear deformable functionally graded single/doubly curved shell panel with TD and TID properties

  • Kar, Vishesh R.;Panda, Subrata K.;Mahapatra, Trupti R.
    • Advances in materials Research
    • /
    • 제5권4호
    • /
    • pp.205-221
    • /
    • 2016
  • In this article, the buckling responses of functionally graded curved (spherical, cylindrical, hyperbolic and elliptical) shell panels under elevated temperature load are investigated numerically using finite element steps. The effective material properties of the functionally graded shell panel are evaluated using Voigt's micromechanical model through the power-law distribution with and without temperature dependent properties. The mathematical model is developed using the higher-order shear deformation theory in conjunction with Green-Lagrange type nonlinear strain to consider large geometrical distortion under thermal load. The efficacy of the proposed model has been checked and the effects of various geometrical and material parameters on the buckling load are analysed in details.

Experiments on the Thermal Stratification in the Branch of NPP

  • Kim Sang Nyung;Hwang Seon Hong;Yoon Ki Hoon
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1206-1215
    • /
    • 2005
  • The thermal stratification phenomena, frequently occurring in the component of nuclear power plant system such as pressurizer surge line, steam generator inlet nozzle, safety injection system (SIS), and chemical and volume control system (CVCS), can cause through-wall cracks, thermal fatigue, unexpected piping displacement and dislocation, and pipe support damage. The phenomenon is one of the unaccounted load in the design stage. However, the load have been found to be serious as nuclear power plant operation experience accumulates. In particular, the thermal stratification by the turbulent penetration or valve leak in the SIS and SCS pipe line can lead these safety systems to failure by the thermal fatigue. Therefore in this study an 1/10 scaledowned experimental rig had been designed and installed. And a series of experimental works had been executed to measure the temperature distribution (thermal stratification) in these systems by the turbulent penetration, valve leak, and heat transfer through valve. The results provide very valuable informations such as turbulent penetration depth, the possibility of thermal stratification by the heat transfer through valve, etc. Also the results are expected to be useful to understand the thermal stratification in these systems, establish the thermal strati­fication criteria and validate the calculation results by CFD Codes such as Fluent, Phenix, CFX.

316L 시험원통의 열라체팅 구조시험에 관한 연구 (A Study on Thermal Ratcheting Structure Test of 316L Test Cylinder)

  • 이형연;김종범;구경회
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.243-249
    • /
    • 2001
  • In this study, the progressive inelastic deformation, so called, thermal ratchet phenomenon which can occur in high temperature liquid metal reactor was simulated with thermal ratchet structural test facility and 316L stainless steel test cylinder. The inelastic deformation of the reactor baffle cylinder can occur due to the moving temperature distribution along the axial direction as the hot free surface moves up and down under the cyclic heat-up and cool-down of reactor operations. The ratchet deformations were measured with the laser displacement sensor and LVDTs after cooling the structural specimen which experiences thermal load up to $550^{\circ}$ and the temperature differences of about $500^{\circ}C$. During structural thermal ratchet test, the temperature distribution of the test cylinder along the axial direction was measured from 28 channels of thermocouples and the temperatures were used for the ratchet analysis. The thermal ratchet deformation analysis was performed with the NONSTA code whose constitutive model is nonlinear combined kinematic and isotropic hardening model and the test results were compared with those of the analysis. Thermal ratchet test was carried out with respect to 9 cycles of thermal loading and the maximum residual displacements were measured to be 1.8mm. It was shown that thermal ratchet load can cause a progressive deformation to the reactor structure. The analysis results with the combined hardening model were in reasonable agreement with those of the tests.

  • PDF

터보과급 대형 CNG기관 피스톤의 온도분포와 열응력 해석 (Numerical Analysis for Temperature Distribution and Thermal Stresses in a Turbocharged Large CNG Engine Piston)

  • 김양술;안수철
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.58-62
    • /
    • 2008
  • 본 연구에서는 직렬 6기통 압축천연가스 엔진의 피스톤에 대한 3차원 모델링을 수행하여 정상상태에서의 온도분포 및 그에 따른 열응력과 변형을 예측하고, 이를 기존의 해석결과와 비교 검토를 통하여 피스톤의 유한요소해석의 기준을 구축하고자 한다. 또한 냉각시스템의 성능이 피스톤의 열부하에 미치는 영향을 평가하기 위하여 냉각수 온도의 변화에 따른 피스톤의 온도분포 및 열응력 분포 그리고 그에 따른 변형을 분석하였다. 분석결과 피스톤의 최고 온도는 크라운부의 중앙에서 나타났고, 피스톤의 크라운 하부에서 최대 열응력이 발생하였다.

  • PDF

공동주택의 발코니 확장이 실내온열환경 및 냉난방 부하에 미치는 영향 (Effect of the Balcony Space on Thermal Environment and Heating/Cooling Load in an Apartment House)

  • 서정민;최영진;송두삼;장현재;김상진
    • 설비공학논문집
    • /
    • 제19권5호
    • /
    • pp.364-371
    • /
    • 2007
  • The former studies for expanding a balcony space were tend to be focused on only quantitative aspects. In this study, the characteristics of balcony space on thermal on vironment in apartment house were analysed. First, the effect of the balcony space on thermal environment of living space was analysed by field measurement. Second, the temperature distribution of the bedroom and heating/cooling load with the balcony expansion were analysed by numerical simulation.

공동주택의 발코니 확장이 실내온열환경 및 냉난방 부하에 미치는 영향 (Effect of the Balcony Space on Thermal Environment and Heating/Cooling Load in an Apartment House)

  • 서정민;송두삼;김상호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.847-853
    • /
    • 2006
  • The former studies for expanding a balcony space were tend to be focused on only quantitative aspects. In this study, the characteristics of balcony space on thermal environment in apartment house were analysed. First, the effect of the balcony space on thermal environment of living space was analysed by field measurement. Second, the temperature distribution of the bedroom and heating/cooling load with the balcony expansion were analysed by numeric at simulation.

  • PDF

열화상 분석을 이용한 전력시스템의 안전진단에 관한 연구 (A Study on the Safety Diagnosis for Electric Power Systems Using Thermal Imaging Analysis)

  • 유병열;김찬오
    • 한국안전학회지
    • /
    • 제26권2호
    • /
    • pp.26-31
    • /
    • 2011
  • In this paper, the safety diagnosis using thermal image analysis is described for power equipments. The conventional three-phase comparison method has only provided the results of thermal comparison for the equipments. The proposed method defines the conditions of poor connection by visual checks, and supports the criteria with each thermal rise step. As a result, the thermal difference from $5^{\circ}C$ to $10^{\circ}C$ meant the warning state. In addition, the thermal difference more than $10^{\circ}C$ meant that the connection status was unbalanced. In this case, the countermeasure might be the internal load distribution. If the thermal difference more than $20^{\circ}C$ is observed, it means a hot spot at the poor connection. If the hot spot is observed all over the surface, its cause was the unbalanced load, which made the conductive parts discolored and raised the possibility of oxidization or $Cu_2O$ generation. This diagnostic technology employing thermal image analysis method can be directly applied in the field and ensures the safety of equipments.

벤틸레이티드 디스크 브레이크의 열응력 해석 (Thermal Stress Analysis of Ventilated Disc Brake)

  • 김양술;안수철
    • 한국안전학회지
    • /
    • 제23권3호
    • /
    • pp.25-29
    • /
    • 2008
  • In automotive disc brake system, friction heat is not uniformly distributed due to various reasons such as thermal expansion and imperfections in geometry. It is well known that thermoelastic distortion due to fictional heating affects the contact pressure distribution and can lead to thermoelastic instability, where the contact load is concentrated in one or more small regions on the brake disc surface. These regions then take very high temperatures and passage of hot spots moving under the brake pads can cause low frequency vibration called brake judder. This paper presents the FEM(finite element method) result for the temperature distribution of ventilated disc brake. A steady state two-dimensional model of disc brake system predicts the surface temperatures during a multi-stop driving schedule.