• 제목/요약/키워드: Thermal interference

검색결과 151건 처리시간 0.028초

전력유도 현상과 차폐계수 (Phenomenon of Power Interference and Screening Factor)

  • 황종선;김영민;이경욱;김재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

간섭 제거기를 사용한 BPSK 다중 톤 DS/CDMA 시스템의 성능 분석 (Performance Analysis of BPSK Multitone DS/CDMA System with Interference Canceller)

  • 박승근;강병권
    • 한국정보통신학회논문지
    • /
    • 제2권4호
    • /
    • pp.519-529
    • /
    • 1998
  • 본 논문에서는 간섭 제거기가 다중 톤 DS/CDMA 시스템의 성능에 미치는 영향을 분석하였다. 최근 여러가지 방법의 간섭 제거기가 제안되고 있으나, 여기서는 Yoon[9] 등이 제안한 간섭 제거기를 사용하였다. 또한 세가지 종류의 간섭을 고려하였는데 다중 경로 간섭, 채널 간 간섭, 다중 접속 간섭이 그것이다. 이들 간섭 신호들과 가우시안 잡음의 분산을 구하여 신호 대 잡음비를 계산하였으며, 다중 경로 채널에서의 RAKE 수신기 와 3단계의 간섭 제거기를 고려하였다. 성능 분석 결과, 간섭 제거기는 다중 톤 CDMA 시스템에서 매우 효과 적이며, 최대비 결합 다이버시티와 심볼 당 칩 수를 증가시킴에 따라 성능이 크게 향상되어 이들 파라메터가 중요한 설계 요소임을 보였다.

  • PDF

Flexural, electrical, thermal and electromagnetic interference shielding properties of xGnP and carbon nanotube filled epoxy hybrid nanocomposites

  • Lee, Young Sil;Park, Yeon Ho;Yoon, Kwan Han
    • Carbon letters
    • /
    • 제24권
    • /
    • pp.41-46
    • /
    • 2017
  • The microstructure, flexural properties, electrical conductivity, thermal conductivity and electromagnetic interference (EMI) shielding effectiveness (SE) of epoxy composites filled with multi-walled carbon nanotubes (CNTs), exfoliated graphite nanoplatelets (xGnPs) and CNT-xGnP hybrid filler were investigated. The EMI SE of the CNT-xGnP hybrid composite was higher than 25 dB at 100 MHz while that of the xGnP based composite was almost zero. The flexural modulus of the CNT-xGnP based epoxy composite continuously increased to 3.32 GPa with combined filler content up to 10 wt% while that of the CNT based epoxy composites slightly decreased to 1.96 GPa at 4 wt% CNT, and dropped to 1.57 GPa at 5 wt% loading, which is lower than that of epoxy. The CNT and CNT-xGnP samples had the same EMI SE at the same surface resistivity, because samples with the same surface conductivity have the same amount of the charge carriers.

지중 열교환기의 순환수에 의한 열응력 및 열전달 거동 분석 (Analysis of thermal stress and heat transfer due to circulating fluid in ground heat exchanger)

  • 길후정;이강자;이철호;최항석;최효범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.385-395
    • /
    • 2009
  • In this study, a series of numerical analysis has been accomplished on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP) considering the circulating fluid, pipe, grout and soil formation. A finite element analysis program, ABAQUS, was employed to evaluate the temperature distribution on the cross section of the U-loop system involving HDPE pipe/grout/formation and to compare sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system. Especially, the latticed pipe is equipped with a thermal insulation zone in order to reduce thermal interference between the inflow pipe and the outflow pipe. Also, a thermal stress analysis was performed with the aid of ABAQUS. 3-D finite volume analysis program, FLUENT, was adapted to analyze a coupled system between fluid circulation in the pipe and heat transfer and simulate an operating process of the closed-loop vertical ground heat exchanger. In this analysis, the effect of the thermal properties of grout, rate of circulation pump, distance between the inflow pipe and the outflow pipe, and the effectiveness of the latticed HDPE pipe system are taken into account.

  • PDF

Development of Lifetime Assessment and Rehabilitation Cost Calculation Methods for Overseas ROMM Project

  • Hyun, Jung-Seob;Kim, Doo-Young;Hwang, Kwang-Won;Park, Min-Gyu
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.119-125
    • /
    • 2017
  • Regarding the implementation of ROMM project (Rehabilitation, Operation, Maintenance & Management), which is one of overseas development projects, it is very important to diagnose the exact current status of aged thermal power plant. However, when people visit the power plant for the purpose of prediagnosis to implement the ROMM project, most target power plants for diagnosis, in general, are under operation. This can be a big interference factor to diagnose the exact current status of power plants. Therefore, in order to solve such interference factor, based on the 30 years of know-how in the field, the present study has developed a regression curve for a simple life time assessment and the calculation of rehabilitation cost that may be used as a reference relatively for the quantitative diagnosis on the status of a relevant power plant even during the operation of the power plant.

고온에서 ESPI에 의한 특수강의 열팽창계수 측정에 관한 연구 (A Study on the Thermal Coefficient Measurements of Special Steel by ESPI at High Temperature)

  • 김경석;양승필;김형수
    • 비파괴검사학회지
    • /
    • 제13권2호
    • /
    • pp.20-30
    • /
    • 1993
  • CW레이저, 비디오장치, 화상처리장치를 이용한 ESPI를 고온에서 자유 열팽창하는 열팽창계수 측정에 적용하였다. ESPI는 이미 선정된 방향의 면내 변위분포를 나타내 준다. ESPI는 간섭 줄무늬를 실시간으로 나타내 주며 면에 비접촉이고 표면의 준비가 필요 없다는 장점이 있다. ESPI를 고온에 적용함에 있어서 줄무늬의 가시도를 저하시키는 여러 가지 문제점에 당면하게 된다. 고온 물체 주위의 뜨거운 공기로 인한 요란의 문제는 진공용기를 사용함으로 해결될 수 있을 것이다. 물체의 배경방사는 간섭 필터에 의해 매우 감소되었다. 물체의 표면 산화의 문제는 해결될 수 없었다. Human-Error를 방지하기 위해 FFT에 의해 계산된 간섭 줄무늬 간격은 $800^{\circ}C$까지 관찰되었다. ESPI에 의해 측정된 결과는 $800^{\circ}C$까지 이미 발표된 데이타와 거의 일치했다.

  • PDF

Multi-level & Multi-bandwidth 시스템에서 위성중계기 입력반송파 전력의 최적 할당 기법 (A Method for Optimal Power Assignment of the Transponder Input Carriers in the Multi-level & Multi-bandwidth System)

  • 김병균;최형진
    • 전자공학회논문지A
    • /
    • 제32A권9호
    • /
    • pp.1167-1176
    • /
    • 1995
  • This paper suggests a method for optimal power assignment of the satellite transponder input carriers in the Multi-level & Multi-bandwidth system. The interference and the noise effects analyzed for the optimal power assignment are intermodulation product caused by the nonlinear transponder characteristics, adjacent channel interference, co-channel interference, and thermal noise in the satellite link. The Fletcher- Powell algorithm is used to determine the optimal input carrier power. The performance criteria for optimal power assignment is classified into 4 categories according to the CNR of destination receiver earth station to meet the requirement for various satellite link environment. We have performed mathematical analysis of objective functions and their derivatives for use in the Fletcher-Powell algorithm, and presented various simulation results based on mathematical analysis. Since the satellite link, it is meaningful to model and analyze these effects in a unified manner and present the method for optimal power assignment of transponder input carriers.

  • PDF

전력유도 현상과 차폐계수 (Phenomenon of Power Interference and Screening Factor)

  • 황종선;김영민;이경욱;김재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

진공관형 태양열 집열기의 내부형상 변화에 따른 성능 비교 (Thermal performance comparisons of the glass evacuated tube solar collectors of different absorber tubes)

  • 김용;서태범;윤성은;김영민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.595-598
    • /
    • 2005
  • The thermal performance of glass evacuated tube solar collectors are numerically and experimentally investigated. Four different shapes of solar collectors are considered and the performances of these solar collectors are compared. Dealing with a single collector tube, the effects of not only the shapes of the absorber tube but also the incidence angle of solar irradiation (beam radiation) on thermal performance of the collector are studied. However the solar irradiation consists of the beam radiation as well as the diffuse radiation. Also, the interference of solar irradiation and heat transfer interaction between the tubes exist in an actual solar collector. These effects are considered in this study experimentally and numerically the accuracy of the numerical model is verified by the experimental results. The result shows that the thermal performance of the absorber used a plate fin and U-tube is the best.

  • PDF