• Title/Summary/Keyword: Thermal insulation material

Search Result 392, Processing Time 0.025 seconds

A Study on the Surface Temperature Change of Building Applied with Thermal Insulation Waterproofing Material During Summer (하절기 차열성능을 갖는 방수재의 적용에 따른 건축물 표면온도 변화추이 연구)

  • Kim, Dong-Bum;Park, Jin-Sang;Choi, Su-Young;Park, Jae-Hong;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.45-46
    • /
    • 2017
  • As the environment and energy problems such as global climate change (global warming, urban heat island phenomenon) and energy depletion have come to the fore, the construction and waterproofing industry are responding more critically to the demands of global green technology and are employing more eco-friendly technologies as of recent. In this study, the application of the waterproofing material with thermal response performance in construction buildings was investigated to confirm whether the thermal performance is being properly secured by the change of the surface temperature. Experimental results showed that the surface temperature difference between before and after the application is at least 19.8℃ at the maximum 26.3℃. When the degradation rate is converted, the degradation effect of about 40% on average was confirmed.

  • PDF

Development of Efficient Curing Sheet for Thermal Insulation Curing of Concrete in Cold Weather

  • Han, Cheon-Goo;Son, Myung-Sik;Choi, Hyun-Kyu
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.3
    • /
    • pp.291-298
    • /
    • 2012
  • For cold weather concreting, frost damage at early age is generated in the concrete, and problems such as delaying of setting and hardening and lowering of strength manifestation emerge due to the low outside air temperature at the early stage of pouring, making the selection of an effective curing method critically important. Unfortunately, the tent sheet currently used as the curing film for heating insulation at work sites, not only has the problems of inferior permeability and extremely deteriorated airtightness, but a phenomenon of continuous fracturing is also generated along the direction of fabric of the material itself, presenting difficult circumstances for maintaining adequate curing temperature. The aim of this study was to develop an improved bubble sheet type curing film for heating insulation of cold weather concrete by combining mesh-tarpaulin, which has excellent tension properties, with bubble sheet, which offers superior insulation performance. The analysis showed that the improved curing film in which BBS1 is stacked to MT was a suitable replacement for curing films currently in use, as it has better permeability, tension property, and insulation performance than the T type film used at work sites today.

Thermal Stress Intensity Factors for Partially Insulated Interface Crack under Uniform Heat Flow (부분 열유동이 있는 접합 경계면균열의 열응력세기계수 결정)

  • 이강용;박상준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.7
    • /
    • pp.1705-1712
    • /
    • 1994
  • Hilbert problems are derived to evaluate thermal stress intensity factors for a partially insulated crack subjected to vertically uniform heat flow in infinite bonded dissimilar materials. In case of fully insulated crack surface, the present solutions of thermal stress intensity factors are reduced into the same as the previous results. For the homogeneous material, mode II thermal stress intensity factor only exists. However, in the bonded dissimilar materials, both mode I and II thermal stress intensity factors are obtained. Specially, in this case, mode II thermal stress intensity factor is dominent. Also, thermal stress intensity factors are strongly influenced by the material properties. Thermal stress intensity factors decrease when the degree of insulation decreases.

Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen (액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성)

  • Lee, Sang-Hwa;Shin, Woo-Ju;Khan, Umer Amir;Oh, Seok-Ho;Sung, Jae-Kyu;Lee, Bang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

Evaluation of Thermal Conductivity of Porous TiO2-SiO2-Base Thermal Insulation (다공성 TiO2-SiO2 복합 단열재의 열전도율 평가)

  • Choi, Byugchul;Kim, Jon-Ho;Kim, Jon Beom;Jung, Woonam;Lee, Sang-Hyun
    • Journal of Institute of Convergence Technology
    • /
    • v.8 no.1
    • /
    • pp.21-25
    • /
    • 2018
  • We developed nano-porous $TiO_2-SiO_2$ composites (commercial name : PTI, porous titania insulator) with low thermal conductivity as thermal insulating material as well as function of photocatalyst. The objectives of this paper are, firstly, to evaluate of the thermal conductivity of the PTI powder in the temperature range from -160 to $250^{\circ}C$, secondly to evaluate of thermal conductivities of insulation materials that is applied PTI powder. The structure of the PTI powder that has the pores size of 20-30 nm and the particle diameter of 2-10 nm. The PTI had a high surface area of $400m^2/g$ and a mean pore size of $45{\AA}$, which was fairly uniform. The thermal conductivity was measured by GHP(guarded hot plate) method and HFM(heat flux method). The PTI structure is a three-dimensional network nano-structures composed by a pearl-necklace that involved a precious stone in the center of the necklace. The thermal conductivities of PTI-PX powder by the GHP and HFM were 0.0366 W/m.K, 0.0314 W/m.K at $20^{\circ}C$, respectively. This is similar to values that are proportional to the square of the absolute temperature of the thermal conductivity of static air. The thermal conductivities of insulating sheets coated with PTI powder were similar results with that of the PTI powder.

The Evaluation of Thermal Properties of Pesticide Protective Clothing using the Surface Temperature Controlled Thermal Manikin (열 마네킹을 이용한 부직포 농약 방호복의 열적 성능 평가)

  • Choi, Jong-Myoung
    • Korean Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.119-127
    • /
    • 1998
  • The purpose of this study was to evaluate thermal properties of pesticide protective clothing made of three different nonwoven fabrics which have barrier properties of pesticide. In order to assay the thermal properties of experimental clothing, thermal resistance measurements for clo value and thermographic assessment were conducted using a surface temperature controlled thermal manikin. The thermal manikin was dressed with underwear and experimental clothing. Air temperature in a climate chamber was kept at $28^{\circ}C$ and its humidity was 70% RH. Air velocity was controlled at less than 0.15m/s. Inner radient temperature was almost equal to the air temperature. The basic thermal insulation value(Icl) of underwear was 0.28 clo. The thermal properties of the experimental clothing were varied according to the type of material used in construction. The basic clothing insulation value for C1(spunbonded nonwoven fabric), C2(spunlaced nonwoven fabric), C3(SMS nonwoven fabric) were 0.705 clo, 0.725 clo, 0.738 clo respectively. The C3 experimental clothing made of SMS resulted in higher surface temperatures than the others with more yellowing spots being evident on the thermogram.

  • PDF

Experimental Research Application to each Types of Insulation Materials in Rural Houses (농촌주택의 단열 재료별 현장 적용을 위한 실험 연구)

  • Kwon, Soon-Chan;Kim, Eun-Ja
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.19 no.4
    • /
    • pp.57-65
    • /
    • 2017
  • Life quality in farming areas is declining these days on account of decrease in population with the outflow of young generations, advent of aging society, and also lack of social and physical infrastructure. To reverse this, the central and local governments have been devising policies in many ways; however, the vulnerable class in farming area suffering from financial difficulty is not supported with that properly. The results of applying insulation materials applicable to rural houses, EPS, e-board, and glass wool, actually to rural houses are summed as follows. EPS is the most inexpensive among the three installations in terms of material cost and expenses. The indoor and outdoor temperature difference increased from $0.9^{\circ}C$ to $2.5^{\circ}C$, and the temperature change reduced as $0.04^{\circ}C$. With e-board, the indoor and outdoor temperature difference increased from $3.3^{\circ}C$ to $7.5^{\circ}C$; however, the temperature change increased as $0.09^{\circ}C$. Unlike the other two methods, glass wool requires the additional installation of wooden frames. The material cost is highest, and the indoor and outdoor temperature difference increased from $1.1^{\circ}C$ to $8.0^{\circ}C$, and the temperature change reduced as $0.01^{\circ}C$. According to the results of measuring temperature, glass wool's temperature difference is measured to be the highest, but temperature change is found to be the most effective in EPS. Among the three insulation methods, EPS is the most economically advantageous as the material supply is easy and the cost is low. The material is easily processible, so ordinary town residents can install it easily, and it is effective at improving insulation performance, too. But this method cannot be applied when the house has walls that are not even. Also, as the insulator is thick, after the installation, the living space may be narrower as a result.

Evaluation of Cryogenic Compressive Strength of Divinycell of NO 96-type LNG Insulation System (NO96타입 LNG 방열시스템 Divinycell의 극저온 압축 강도 평가)

  • Choe, Yeong-Rak;Kim, Jeong-Hyeon;Kim, Jong-Min;Park, Sungkyun;Park, Kang Hyun;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.5
    • /
    • pp.349-355
    • /
    • 2016
  • Divinycell, which functions as both insulation and a supporting structure, is generally applied in the NO96-type liquefied natural gas (LNG) insulation system. Polymer-material-based Divinycell, which has a high strength and low weight, has been widely used in the offshore, transportation, wind power generation, and civil engineering fields. In particular, this type of material receives attention as an insulation material because its thermal conductivity can be lowered depending on the ambient temperature. However, it is difficult to obtain research results for Divinycell, even though the component materials of the NO96-type LNG cargo containment system, such as 36% nickel steel (invar steel), plywood, perlite, and glass wool, have been extensively studied and reported. In the present study, temperature and strain-rate dependent compressive tests on Divinycell were performed. Both the quantitative experimental data and elastic recovery are discussed. Finally, the mechanical characteristics of Divinycell were compared to the results of polyurethane foam insulation material.

Fault Prediction & Reliability Estimation of the Traction Motor by the Complex Accelerating Degradation and Condition Diagnosis (견인전동기의 복합가속열화 상태진단에 의한 고장예측 및 신뢰성 평가)

  • 왕종배;김명룡
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.763-766
    • /
    • 2000
  • In this paper, stator form-winding sample coils based on silicone resin and polyimide were made for fault prediction and reliability estimation on the 200 Class insulation system of traction motors. The complex accelerative degradation was performed by periods during 10 cycles, which was composed of thermal stress, fast rising surge voltage, vibration, water immersion and overvoltage applying. After aging of 10 cycles, condition diagnosis test such as insulation resistance & polarization index, capacitance & dielectric loss and partial discharge properties were investigated in the temperature range of 20∼160$^{\circ}C$. Relationship among condition diagnosis test was analyzed to find an dominative degradation factor and an insulation state at end-life point.

  • PDF