• 제목/요약/키워드: Thermal growing season

검색결과 16건 처리시간 0.021초

한반도의 기후학적 식물생육기간의 변화 (Change of Climatic Growing Season in Korea)

  • 정명표;심교문;김용석;최인태
    • 한국환경농학회지
    • /
    • 제34권3호
    • /
    • pp.192-195
    • /
    • 2015
  • BACKGROUND: The growing season (GS) has been understood as a useful indicator for climate change due to high relationship with increasing temperature. Hear this study was conducted to examine changes in the thermal GS over South Korea from 1970 to 2013 based on daily mean air temperature for assessing the temporal and spatial variability in GS. METHODS AND RESULTS: Three GS parameters (starting date, ending date, and length) were determined at 19 stations throughout South Korea. The results show that the GS has been extended by 4.2 days/decade between 1970 and 2013 on average. The growing season start (GSS) has been advanced by 2.7 days/decade and the growing season end (GSE) has been delayed by 1.4 day/decade. Spatial variation in the GS parameters in Korea are shown. The GS parameters, especially GSS, of southeastern part of Korea have been changed more than that of northwestern part of Korea. The extension of GS may be more influenced on earlier onset in spring rather than later GSE. CONCLUSION: Under climate change scenarios, the GS will be more extended due to delayed GSE as well as advanced GSS. And These are more notable in the northeastern part of Korea.

해수를 이용한 화력발전소 폐열회수 히트펌프 시스템 (Heat Pump System Using Heated Effluent of Thermal Power Generation Plant as a Heat Source)

  • 유영선;강연구;김영화;장재경;김종구;이형모;강금춘;나규동;허태현
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.190-190
    • /
    • 2011
  • In South Korea the gross generation and heated effluent of power generation plant was 259 TWh and 4.73 billion tons in 2008. And then the waste heat from power generation was 388 TWh. It shows that the efficiency of thermal power generation plant is about 40%. Therefore to reduce $CO_2$ emission from thermal power generation plant, the energy of this heated effluent must be reused to heat buildings or farm facilities. In South Korea horticultural facilities of about 25% are heated in winter season. Total area of greenhouses which are heated is about 13,000 ha. Total heat amount needed to warm greenhouse of 13,000 ha in winter season is only 3.4% of total waste heat from power generation plant. In this study a heat pump system was designed to reuse the waste heat from power generation. Especially new heat exchanger was developed to recover the thermal energy from waste water and this model considered anti-corrosion against sea water and low cost for economic feasibility. This heat recovery system was installed in mango growing greenhouse around thermal power generation plant in Seogwipo-city, Jeju Special Self-Governing Province. The result of preliminary test shows that the heating cost of about 90% is saved as compared to boiler using tax free light oil as a fuel.

  • PDF

한국의 극한 기온 및 강수 사상의 변화 경향에 관한 연구 (Trends on Temperature and Precipitation Extreme Events in Korea)

  • 최영은
    • 대한지리학회지
    • /
    • 제39권5호
    • /
    • pp.711-721
    • /
    • 2004
  • 기상과 관련된 재해의 직접 원인이 되는 극한 기후 사상의 발생 빈도 및 강도의 변화 경향을 파악하는 것이 된 연구의 목적이다. 일최저기온, 일최고기온, 일강수량 자료를 이용하여, 10개 기후 변화 지시자를 산출하였다. 그 변화 경향의 공간 분포를 파악하였다. 일최저기온을 이용하여 산출된 온난야의 발생 빈도는 한반도에서 증가하는 추세를 나타냈고. 최저기온의 증가로 인하여 서리일수는 감소하고 생장기간은 증가하였다. 매해의 일최저기온과 일최고기온의 차로 산출되는 연극한기온교차는 최고기온은 변화하지 않았지만. 최저기온의 증가로 인하여 감소하고 있다. 강수와 관련된 지시자들은 기온 관련 지시자에 비하여 변화 경향이 뚜렷하지 않지만, 무강수일수의 한반도 시계열은 감소하는 경향이 나타났고, 호우지수로 분류될 수 있는 강수강도는 증가하고 있다.

겨울철 공동주택에서 붙박이장 내 보조난방장치를 활용한 결로 저감 효과 평가 (Assessment of Utilization of Auxiliary Heating Device for Prevention of Condensation in Built-in Furniture in Winter)

  • 이현화;임재한;송승영
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.99-106
    • /
    • 2017
  • Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions and surface temperature around the built-in furniture were measured during winter season. In this research, we analyzed thermal conditions for built-in furniture which were applied and not applied auxiliary heating device. In results, it is important to consider increasing surface temperature for using heater and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

태양에너지를 이용한 겨울철 미꾸라지 성장에 관한 연구 (Misgurnus Anguillicaudatus Growing in Winter Season by Solar Thermal Heating)

  • 정현채;선경호;조재선;남상열
    • 태양에너지
    • /
    • 제11권3호
    • /
    • pp.31-36
    • /
    • 1991
  • 태양열 온수기로부터 획득한 $50{\sim}60^{\circ}C$의 온수를 이용하여 수온이 낮은 3, 4, 10, 11월은 물론 한 겨울철에도 미꾸리의 최적 성장온도를 유지시켰던 바 다음과 같은 결과를 얻었다. 가. 전장 $4{\sim}5cm$, 체중 $1{\sim}2g$정도의 미꾸리의 최적 성장수온은 $18{\sim}20^{\circ}C$이고 $5{\sim}7cm,\;2{\sim}3g$인 것은 $20{\sim}22^{\circ}C$이고 $7{\sim}9cm,\;4{\sim}6g$인 것은 $22{\sim}24^{\circ}C$의 수온임을 알아냈다. 나. $1{\sim}3g$의 개체는 서서히 성장하나 $4{\sim}8g$의 것은 성장이 빠르고 총개체수의 무게 총량은 1개월간에 약 $30{\sim}50g$ 증가하였다.

  • PDF

Development of a Drought Detection Indicator using MODIS Thermal Infrared Data

  • Park, Sun-Yurp
    • 대한원격탐사학회지
    • /
    • 제20권1호
    • /
    • pp.1-11
    • /
    • 2004
  • Based on surface energy balance climatology, surface temperatures should respond to drying conditions well before plant response. To test this hypothesis, land surface temperatures (LST) derived from MODIS data were analyzed to determine how the data were correlated with climatic water balance variables and NDVI anomalies during a growing season in Western and Central Kansas. Daily MODIS data were integrated into weekly composites so that each composite data set included the maximum temperature recorded at each pixel during each composite period. Time-integrated, or cumulative values of the LST deviation standardized with mean air temperatures had significantly high correlation coefficients with SM, AE/PE, and MD/PE, ranging from 0.65 to 0.89. The Standardized Thermal Index (STI) is proposed in this study to accomplish the objective. The STI, based on surface temperatures standardized with observed mean air temperatures, had significant temporal relationships with the hydroclimatological factors. STI classes in all the composite periods also had a strong correlation with NDVI declines during a drought episode. Results showed that, based on LST, air temperature observations, and water budget analysis, NDVI declines below normal could be predicted as early as 8 weeks in advance in this study area.

Optical Method for Measuring Deposition Amount of Black Carbon Particles on Foliar Surface

  • Yamaguchi, Masahiro;Takeda, Kenta;Otani, Yoko;Murao, Naoto;Sase, Hiroyuki;Lenggoro, I. Wuled;Yazaki, Kenichi;Noguchi, Kyotaro;Ishida, Atsushi;Izuta, Takeshi
    • Asian Journal of Atmospheric Environment
    • /
    • 제6권4호
    • /
    • pp.268-274
    • /
    • 2012
  • To perform quick measurements of black carbon (BC) particles deposited on foliar surfaces of forest tree species, we investigated an optical method for measuring the amount of BC extracted from foliar surfaces and collected on quartz fiber filters. The seedlings of Fagus crenata, Castanopsis sieboldii, Larix kaempferi and Cryptomeria japonica were exposed to submicron BC particles for one growing season (1 June to 7 December 2009). At the end of the growing season, the leaves or needles of the seedlings were harvested and washed with deionized water followed by washing with chloroform to extract the BC particles deposited on the foliar surfaces. The extracted BC particles were collected on a quartz fiber filter. The absorption spectrum of the filters was measured by spectrophotometer with an integrating sphere. To obtain the relationship between the absorbance of the filter and the amount of BC particles on the filter, the amount of BC particles on the filter was determined as that of elemental carbon (EC) measured by a thermal optical method. At wavelengths below 450 nm, the absorption spectrum of the filter showed absorption by biological substances, such as epicuticular wax, resulting in the low coefficient of determination ($R^2$) in the relationship between the amount of EC on the filter ($M_{EC}$, ${\mu}g\;C\;cm^{-2}$ filter area) and the absorbance of the filter. The intercept of the regression line between $M_{EC}$ and the absorbance of the filter at 580 nm ($A_{580}$) was closest to 0. There was a significant linear relationship between the $A_{580}$ and $M_{EC}$ ($R^2$=0.917, p<0.001), suggesting that the amount of BC particles collected on the filter can be predicted from the absorbance. This optical method might serve as a simple, fast and cost-effective technique for measuring the amount of BC on foliar surfaces.

Assessment of Greenhouse Gas Emissions from Poultry Enteric Fermentation

  • Wang, Shu-Yin;Huang, Da-Ji
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제18권6호
    • /
    • pp.873-878
    • /
    • 2005
  • Emissions of nitrous oxide (N$_2$O) and methane (CH$_4$) from poultry enteric fermentation were investigated using a respiration chamber. Birds were placed in a respiration chamber for certain intervals during their growing period or for the whole life cycle. The accumulated gas inside the chamber was sampled and analyzed for N$_2$O and CH$_4$ production. A curve for gas production during a life cycle was fitted. The calculated area under the curve estimated the emission factor of poultry enteric fermentation on a life cycle basis (mg bird$^{-1}$ life cycle$^{-1}$). This method can be used to estimate CH$_4$ or N$_2$O emissions from different types of avian species taking into account factors such as diet, season or thermal effects. The CH$_4$/N$_2$O emission factors estimated for commercial broiler chickens, Taiwan country chickens and White Roman Geese were 15.87/0.03, 84.8/16.4 and 1,500/49 (mg bird$^{-1}$ life cycle$^{-1}$), respectively, while the calculated CH$_4$/N$_2$O emission from enteric fermentations were 3.03/0.006, 14.73/2.84 and 9.5/0.31 (Mg year$^{-1}$), respectively in Taiwan in the year of 2000. The described method is applicable to most poultry species and the reported emission factors were applicable to meat type poultry only.

이층커튼 온풍난방 플라스틱온실의 겨울철 포차 및 결로량 변화 (Variation of Vapor Pressure Deficit and Condensation Flux of Air Heating Plastic Greenhouse Installed with Two Layers Thermal Curtain in Winter)

  • 이현우;김영식;심상연;이종원
    • 생물환경조절학회지
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 2013
  • 본 연구는 우리나라 온실 피복재의 결로 발생을 억제하는데 필요한 기초자료를 제공하기 위하여 토마토 재배용 실험온실의 포차변화 및 피복재에 발생하는 결로량의 변화를 분석하였으며 결과를 요약하면 다음과 같다. 실험온실의 경우 포차가 병 발생을 유발하기 쉬운 한계포차인 0.2kPa보다 더 크게 유지되어 온습도환경이 양호한 것으로 판단되었고 제습여부 결정을 위한 임계포차인 0.5kPa보다는 작게 나타나 제습은 필요한 것으로 판단되었다. 내부피복재의 표면온도는 외부온도와 커튼상부온도의 평균값 보다 약간 더 큰 것으로 나타났으며, 대체로 외부온도의 변화에 비례하여 변화하는 것으로 나타났다. 외부의 온도 및 습도 변화에 상관없이 커튼 상부의 습도는 거의 100%에 가까운 상대습도를 유지하여 결로 발생이 용이한 조건인 것으로 나타났다. 커튼하부의 습도는 내부습도의 큰 변화에도 불구하고 75~90% 정도로 안정된 값을 유지하였으며, 이는 온풍난방을 실시하여 온도를 $15^{\circ}C$로 유지하였기 때문으로 판단된다. 실험조건 및 피복재의 종류에 따라 결로 발생량은 많은 차이가 있는 것으로 알려져 있다. 실험온실의 결로 발생량은 Seginer와 Kantz(1986)의 연구결과와 가장 잘 일치하는 것으로 나타났으나 다른 온실실험 결과들과는 약간의 차이를 보여주고 있기 때문에 앞으로 실험을 통해서 더 자세한 검증을 거친다면 우리나라 온실 피복재에 발생하는 결로량을 분석하는데 유용하게 활용될 수 있을 것으로 기대된다.

상업용 플라스틱 온실의 광합성유효광량자속 변화 (Variation of Photosynthetic Photon Flux in Commercial Plastic Greenhouses)

  • 이현우;김영식
    • Current Research on Agriculture and Life Sciences
    • /
    • 제30권1호
    • /
    • pp.27-33
    • /
    • 2012
  • 본 연구는 우리나라 플라스틱온실 피복재의 피복방법 및 관리방법을 개선할 수 있는 방안을 구명하는데 필요한 자료를 제공하기 위하여 상업용으로 운영되고 있는 대표적인 구조 및 피복형태의 온실에 대하여 겨울철 온실 내부의 광합성유효광량자속을 측정하고 변화를 분석하였으며 결과를 요약하면 다음과 같다. 일일적산 광합성유효광량자속의 월중 변화를 분석한 결과 모든 온실에 있어서 광량변화의 경향이 일조시간의 변화 경향과 대체로 잘 일치하는 것으로 나타났으나, 온실 간에 일일적산 광량의 차이는 상당히 큰 것으로 나타났으며, 겨울철에는 모든 온실이 토마토 생육에 필요한 적정 광량에 미치지 못하는 것으로 나타났다. 월평균 일일적산 광합성유효광량자속의 연중변화를 분석한 결과 실험온실 모두 투과광량을 높이기 위하여 겨울철에도 내부피복재를 대부분 개방하였기 때문에 내부피복재의 오염으로 인한 광투과율의 저하는 미미하였으며 주로 외부피복재의 오염으로 인해 투과광량이 감소하는 것으로 분석되었다. PO필름으로 피복된 단동온실의 광 투과 성능이 매우 우수하다는 사실을 확인할 수 있었다. 피복재를 더 효율적으로 사용하기 위해서는 피복재의 교체시기를 겨울철광량이 부족한 시기가 시작되기 전인 10월 또는 11월경으로 하는 것이 바람직할 것으로 판단되었다. 온실간 광량의 차이가 최대 40%정도까지 나기 때문에 투과광량이 낮은 온실은 즉시 피복재를 교체하여 광투과율을 높이는 것이 경제적일 것으로 판단되었다. 온실의 투과광량 감소요인을 분석한 결과 투과광량을 감소시키는 내부요인은 보온커튼, 내부피복재, 결로받이 등인 것으로 분석되었다. 광폭형 단동온실의 경우에는 비교적 넓은 온실 폭의 중앙에 보온커튼과 내부피복재를 걷어 두고 있기 때문에 온실 전체 폭에 비해 걷혀 있는 보온커튼과 내부피복재의 폭이 비교적 작아 다른 온실에 비해 광 손실이 상대적으로 적을 것으로 분석되었다. 종합적으로 비교해 볼 때 광폭형 단동온실이 광 투과 측면에서 가장 우수한 것으로 나타났고 내부피복재를 중앙에서 권취하여 개방하는 형태의 온실이 가장 바람직하지 못한 것으로 분석되었다.

  • PDF