• Title/Summary/Keyword: Thermal growing season

Search Result 16, Processing Time 0.032 seconds

Change of Climatic Growing Season in Korea (한반도의 기후학적 식물생육기간의 변화)

  • Jung, Myung-Pyo;Shim, Kyo-Moon;Kim, Yongseok;Choi, In-Tae
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.3
    • /
    • pp.192-195
    • /
    • 2015
  • BACKGROUND: The growing season (GS) has been understood as a useful indicator for climate change due to high relationship with increasing temperature. Hear this study was conducted to examine changes in the thermal GS over South Korea from 1970 to 2013 based on daily mean air temperature for assessing the temporal and spatial variability in GS. METHODS AND RESULTS: Three GS parameters (starting date, ending date, and length) were determined at 19 stations throughout South Korea. The results show that the GS has been extended by 4.2 days/decade between 1970 and 2013 on average. The growing season start (GSS) has been advanced by 2.7 days/decade and the growing season end (GSE) has been delayed by 1.4 day/decade. Spatial variation in the GS parameters in Korea are shown. The GS parameters, especially GSS, of southeastern part of Korea have been changed more than that of northwestern part of Korea. The extension of GS may be more influenced on earlier onset in spring rather than later GSE. CONCLUSION: Under climate change scenarios, the GS will be more extended due to delayed GSE as well as advanced GSS. And These are more notable in the northeastern part of Korea.

Heat Pump System Using Heated Effluent of Thermal Power Generation Plant as a Heat Source (해수를 이용한 화력발전소 폐열회수 히트펌프 시스템)

  • Ryou, Y.S.;Kang, Y.K.;Kim, Y.H.;Jang, J.K.;Kim, J.G.;Lee, H.M.;Kang, G.C.;Nah, K.D.;Huh, T.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.190-190
    • /
    • 2011
  • In South Korea the gross generation and heated effluent of power generation plant was 259 TWh and 4.73 billion tons in 2008. And then the waste heat from power generation was 388 TWh. It shows that the efficiency of thermal power generation plant is about 40%. Therefore to reduce $CO_2$ emission from thermal power generation plant, the energy of this heated effluent must be reused to heat buildings or farm facilities. In South Korea horticultural facilities of about 25% are heated in winter season. Total area of greenhouses which are heated is about 13,000 ha. Total heat amount needed to warm greenhouse of 13,000 ha in winter season is only 3.4% of total waste heat from power generation plant. In this study a heat pump system was designed to reuse the waste heat from power generation. Especially new heat exchanger was developed to recover the thermal energy from waste water and this model considered anti-corrosion against sea water and low cost for economic feasibility. This heat recovery system was installed in mango growing greenhouse around thermal power generation plant in Seogwipo-city, Jeju Special Self-Governing Province. The result of preliminary test shows that the heating cost of about 90% is saved as compared to boiler using tax free light oil as a fuel.

  • PDF

Trends on Temperature and Precipitation Extreme Events in Korea (한국의 극한 기온 및 강수 사상의 변화 경향에 관한 연구)

  • Choi, Young-Eun
    • Journal of the Korean Geographical Society
    • /
    • v.39 no.5 s.104
    • /
    • pp.711-721
    • /
    • 2004
  • The aim of this study is to clarify whether frequency and/or severity of extreme climate events have changed significantly in Korea during recent years. Using the best available daily data, spatial and temporal aspects of ten climate change indicators are investigated on an annual and seasonal basis for the periods of 1954-1999. A systematic increase in the $90^{th}$ percentile of daily minimum temperatures at most of the analyzed areas has been observed. This increase is accompanied by a similar reduction in the number of frost days and a significant lengthening of the thermal growing season. Although the intra-annual extreme temperature range is based on only two observations, it provides a very robust and significant measure of declining extreme temperature variability. The five precipitation-related indicators show no distinct changing patterns for spatial and temporal distribution except for the regional series of maximum consecutive dry days. Interestingly, the regional series of consecutive dry days have increased significantly while the daily rainfall intensity index and the fraction of annual total precipitation due to events exceeding the $95^{th}$ percentile for 1901-1990 normals have insignificantly increased.

Assessment of Utilization of Auxiliary Heating Device for Prevention of Condensation in Built-in Furniture in Winter (겨울철 공동주택에서 붙박이장 내 보조난방장치를 활용한 결로 저감 효과 평가)

  • Lee, Hyun-Hwa;Lim, Jae-Han;Song, Seung-Yeong
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.99-106
    • /
    • 2017
  • Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Most of all, occupants in residential buildings has suffered from property damages due to the condensation and mold of built-in furniture. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. The aim of paper is to analyze the characteristics of adjacent area around built-in furniture's condensation problem and the thermal environment around the built-in furniture in winter through the field measurements at apartment buildings. In this research, the thermal conditions and surface temperature around the built-in furniture were measured during winter season. In this research, we analyzed thermal conditions for built-in furniture which were applied and not applied auxiliary heating device. In results, it is important to consider increasing surface temperature for using heater and decreasing absolute humidity due to the occupants' behavior around built-in furniture for preventing condensation.

Misgurnus Anguillicaudatus Growing in Winter Season by Solar Thermal Heating (태양에너지를 이용한 겨울철 미꾸라지 성장에 관한 연구)

  • Jung, Hyun-Chai;Sun, Kyung-Ho;Jo, Jae-Sun;Nam, Sang-Yul
    • Solar Energy
    • /
    • v.11 no.3
    • /
    • pp.31-36
    • /
    • 1991
  • We have maintained the optimum water temperature for misgumus in winter season by solar thermal heating energy. The optimum temperatures for the misgumus anguillicaudatus were experimentally estimated, i.e. for the total length $4{\sim}5cm$ and body weight $1{\sim}2g$, the optimum temperature was $18{\sim}20^{\circ}C$. For the total length $5{\sim}7cm$, body weight $2{\sim}3g$ was $20{\sim}22^{\circ}C$ and for the total length $7{\sim}9cm$, body weight $4{\sim}6g$ was $22{\sim}24^{\circ}C$. The smaller misgumas($1{\sim}3g$) grows relatively slow but the bigger one($4{\sim}8g$) grows relatively fast and total average body weight increment was about $30{\sim}50g$ per month.

  • PDF

Development of a Drought Detection Indicator using MODIS Thermal Infrared Data

  • Park, Sun-Yurp
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Based on surface energy balance climatology, surface temperatures should respond to drying conditions well before plant response. To test this hypothesis, land surface temperatures (LST) derived from MODIS data were analyzed to determine how the data were correlated with climatic water balance variables and NDVI anomalies during a growing season in Western and Central Kansas. Daily MODIS data were integrated into weekly composites so that each composite data set included the maximum temperature recorded at each pixel during each composite period. Time-integrated, or cumulative values of the LST deviation standardized with mean air temperatures had significantly high correlation coefficients with SM, AE/PE, and MD/PE, ranging from 0.65 to 0.89. The Standardized Thermal Index (STI) is proposed in this study to accomplish the objective. The STI, based on surface temperatures standardized with observed mean air temperatures, had significant temporal relationships with the hydroclimatological factors. STI classes in all the composite periods also had a strong correlation with NDVI declines during a drought episode. Results showed that, based on LST, air temperature observations, and water budget analysis, NDVI declines below normal could be predicted as early as 8 weeks in advance in this study area.

Optical Method for Measuring Deposition Amount of Black Carbon Particles on Foliar Surface

  • Yamaguchi, Masahiro;Takeda, Kenta;Otani, Yoko;Murao, Naoto;Sase, Hiroyuki;Lenggoro, I. Wuled;Yazaki, Kenichi;Noguchi, Kyotaro;Ishida, Atsushi;Izuta, Takeshi
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.4
    • /
    • pp.268-274
    • /
    • 2012
  • To perform quick measurements of black carbon (BC) particles deposited on foliar surfaces of forest tree species, we investigated an optical method for measuring the amount of BC extracted from foliar surfaces and collected on quartz fiber filters. The seedlings of Fagus crenata, Castanopsis sieboldii, Larix kaempferi and Cryptomeria japonica were exposed to submicron BC particles for one growing season (1 June to 7 December 2009). At the end of the growing season, the leaves or needles of the seedlings were harvested and washed with deionized water followed by washing with chloroform to extract the BC particles deposited on the foliar surfaces. The extracted BC particles were collected on a quartz fiber filter. The absorption spectrum of the filters was measured by spectrophotometer with an integrating sphere. To obtain the relationship between the absorbance of the filter and the amount of BC particles on the filter, the amount of BC particles on the filter was determined as that of elemental carbon (EC) measured by a thermal optical method. At wavelengths below 450 nm, the absorption spectrum of the filter showed absorption by biological substances, such as epicuticular wax, resulting in the low coefficient of determination ($R^2$) in the relationship between the amount of EC on the filter ($M_{EC}$, ${\mu}g\;C\;cm^{-2}$ filter area) and the absorbance of the filter. The intercept of the regression line between $M_{EC}$ and the absorbance of the filter at 580 nm ($A_{580}$) was closest to 0. There was a significant linear relationship between the $A_{580}$ and $M_{EC}$ ($R^2$=0.917, p<0.001), suggesting that the amount of BC particles collected on the filter can be predicted from the absorbance. This optical method might serve as a simple, fast and cost-effective technique for measuring the amount of BC on foliar surfaces.

Assessment of Greenhouse Gas Emissions from Poultry Enteric Fermentation

  • Wang, Shu-Yin;Huang, Da-Ji
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.6
    • /
    • pp.873-878
    • /
    • 2005
  • Emissions of nitrous oxide (N$_2$O) and methane (CH$_4$) from poultry enteric fermentation were investigated using a respiration chamber. Birds were placed in a respiration chamber for certain intervals during their growing period or for the whole life cycle. The accumulated gas inside the chamber was sampled and analyzed for N$_2$O and CH$_4$ production. A curve for gas production during a life cycle was fitted. The calculated area under the curve estimated the emission factor of poultry enteric fermentation on a life cycle basis (mg bird$^{-1}$ life cycle$^{-1}$). This method can be used to estimate CH$_4$ or N$_2$O emissions from different types of avian species taking into account factors such as diet, season or thermal effects. The CH$_4$/N$_2$O emission factors estimated for commercial broiler chickens, Taiwan country chickens and White Roman Geese were 15.87/0.03, 84.8/16.4 and 1,500/49 (mg bird$^{-1}$ life cycle$^{-1}$), respectively, while the calculated CH$_4$/N$_2$O emission from enteric fermentations were 3.03/0.006, 14.73/2.84 and 9.5/0.31 (Mg year$^{-1}$), respectively in Taiwan in the year of 2000. The described method is applicable to most poultry species and the reported emission factors were applicable to meat type poultry only.

Variation of Vapor Pressure Deficit and Condensation Flux of Air Heating Plastic Greenhouse Installed with Two Layers Thermal Curtain in Winter (이층커튼 온풍난방 플라스틱온실의 겨울철 포차 및 결로량 변화)

  • Lee, Hyun-Woo;Kim, Young-Shik;Sim, Sang-Youn;Lee, Jong-Won
    • Journal of Bio-Environment Control
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2013
  • This study was conducted to provide data necessary for reducing the condensation on greenhouse covering in winter season. The variation of VPD (Vapor Pressure Deficit) and condensation flux was analyzed in experimental tomato greenhouse. VPD values in experimental plastic greenhouse were greater than 0.2 kPa of disease prevention threshold, and lower than 0.5 kPa of threshold for dehumidification. The surface temperature of inside covering was slightly higher than the average temperature of outside and above curtain, and changed according to outside temperature. The humidity above curtain was nearly 100% and good condition for condensation. The humidity below curtain was 75~90% and comparatively stable condition for growing. The condensation flux value in experimental greenhouse corresponded with result of Seginer and Kantz (1986).

Variation of Photosynthetic Photon Flux in Commercial Plastic Greenhouses (상업용 플라스틱 온실의 광합성유효광량자속 변화)

  • Lee, Hyun-Woo;Kim, Young-Shik
    • Current Research on Agriculture and Life Sciences
    • /
    • v.30 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • This study was conducted to provide data necessary for clearing up the way to be able to improve covering and management method of covering material in commercial plastic greenhouse. The photosynthetic photon flux(PPF) in representative 4 different commercial tomato greenhouses was measured and analyzed. The variation trend of daily integral PPF was in agreement with that of the duration of sunshine. Each of daily integral PPF for 4 different experimental greenhouses was quite dissimilar, and was less than the amount of PPF necessary to grow tomato. October to November of beginning of winter was a good season to replace covering material in order to secure more PPF during insufficient winter season in greenhouse. The main inside factors to interrupt PPF incidence were thermal screen, inside covering material, condensation receiver in greenhouse. The single wide span greenhouse covered with PO film was superior to the other experimental greenhouses in the aspect of PPF transmittance.

  • PDF