• Title/Summary/Keyword: Thermal field

Search Result 2,566, Processing Time 0.037 seconds

Thermal Conduction in Transparent Carbon Nanotube Films

  • Zhu, Lijing;Kim, Duck-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.201-201
    • /
    • 2012
  • Using materials with high thermal conductivity is a matter of great concern in the field of thermal management. In this study, we present our experimental results on an important physical property of carbon nanotube (CNT) films, two-dimensional thermal conductivity obtained by using an optical method based on Raman spectroscopy. We prepared four kinds of CNT films to investigate the effect of CNT type on heat spreading performance of films. This first comparative study using the optical method shows that the arc-discharge single-walled carbon nanotubes yield the best heat spreading film. And we observed thermal conductivity values of CNT films with various transmittances and found that the Raman method works as long as the sample is a transparent film. This study provides useful information on characterization of thermal conduction in transparent CNT films and could be an important step toward high-performance carbon-based heat spreading films.

  • PDF

Investigating nonlinear thermal stability response of functionally graded plates using a new and simple HSDT

  • Bensaid, Ismail;Bekhadda, Ahmed;Kerboua, Bachir;Abdelmadjid, Cheikh
    • Wind and Structures
    • /
    • v.27 no.6
    • /
    • pp.369-380
    • /
    • 2018
  • In this research work, nonlinear thermal buckling behavior of functionally graded (FG) plates is explored based a new higher-order shear deformation theory (HSDT). The present model has just four unknowns, by using a new supposition of the displacement field which enforces undetermined integral variables. A shear correction factor is, thus, not necessary. A power law distribution is employed to express the disparity of volume fraction of material distributions. Three kinds of thermal loading, namely, uniform, linear, and nonlinear and temperature rises over z-axis direction are examined. The non-linear governing equations are resolved for plates subjected to simply supported boundary conditions at the edges. The results are approved with those existing in the literature. Impacts of various parameters such as aspect and thickness ratios, gradient index, type of thermal load rising, on the non-dimensional thermal buckling load are all examined.

Evaluation of Thermal Response Test of Energy Pile (에너지 파일의 현장 열응답 시험에 관한 연구)

  • Yoon, Seok;Lee, Seung-Rae;Kim, Min-Jun;Go, Gyu-Hyun
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.93-99
    • /
    • 2014
  • Use of geothermal energy has been increased for its economical application and environmentally friendly utilization. Particularly, for energy piles, a spiral coil type ground heat exchanger (GHE) is more preferred than line type GHEs such as U and W shaped GHEs. A PHC energy pile with spiral coil type GHE was installed in an area of partially saturated dredged soil deposit, and a thermal response test (TRT) was conducted for 240 hours under a continuous operation condition. Besides, remolded soil samples from different layers were collected in the field, and soil specimens were reconstructed according to the field ground condition. Non-steady state probe methods were conducted in the lab, and ground thermal conductivity and thermal diffusivity were measured for the different soil layers. An equivalent ground thermal conductivity was calculated from the lab test results and it was compared with the field TRT result. The difference was less than 5%, which advocates the use of an equivalent ground thermal conductivity for the multi-layered ground. Furthermore, this paper also represents an equivalent ground thermal diffusivity evaluation method which is another very important design parameter.

Development of numerical model for estimating thermal environment of underground power conduit considering characteristics of backfill materials (되메움재 특성을 고려한 전력구 열환경 변화 예측 수치해석모델 개발)

  • Kim, Gyeonghun;Park, Sangwoo;Kim, Min-Ju;Lee, Dae-Soo;Choi, Hangseok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.121-141
    • /
    • 2017
  • The thermal analysis of an underground power conduit for electrical cables is essential to determine their current capacity with an increasing number of demands for high-voltage underground cables. The temperature rises around a buried cable, caused by excessive heat dissipation, may increase considerably the thermal resistance of the cables, leading to the danger of "thermal runaway" or damaging to insulators. It is a key design factor to develop the mechanism on thermal behavior of backfilling materials for underground power conduits. With a full-scale field test, a numerical model was developed to estimate the temperature change as well as the thermal resistance existing between an underground power conduit and backfill materials. In comparison with the field test, the numerical model for analyzing thermal behavior depending on density, moisture content and soil constituents is verified by the one-year-long field measurement.

A Study on the thermal and electrical stability of PVDF organic thin films fabricated by physical vapor deposition method. (진공증착법을 이용하여 제조한 PVDF 유기 박막의 열적.전기적 안정 특성에 관한 연구)

  • 박수홍;이덕출
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.2
    • /
    • pp.93-101
    • /
    • 1999
  • The purposed of this paper is to investigate the electrical and thermal stability of Polyvinylidene fluoride(PVDF) organic thin films prepared by the vapor deposition method. The differential scanning calorimetry curve of the PVDF organic thin films prepared by increasing substrate temperature showed that the melting curve increased from $128^{\circ}C$ to $142^{\circ}C$. This result implied that the PVDF organic thin film prepared by increasing substrate temperature increased intermolecular force in the crystalline region. The anomalous properties in dielectric constant and dielectric loss at low frequency and high temperature were described for PVDF organic thin film containing impurity carriers. It was confirmed that in view of electric conductive characteristics the ohm's law is satisfied in the range of lower electric field and ln J was proportional to the electric field ln E as like the conventional property of ionic conduction in the range of higher electric field. It was confirmed that major carrier of conductivity was ions. The electrical stability was improved according to an increase of the substrate temperature. On the basis of this experimental result, it could be observed that the optimum temperature of substrate for the electrical and thermal stability was at $105^{\circ}C$.

  • PDF

Pile-up of phosphorus emitters using thermal oxidation (열산화법에 의한 phosphorus 에미터 pile-up)

  • Boo, Hyun Pil;Kang, Min Gu;Lee, KyungDong;Lee, Jong-Han;Tark, Sung Ju;Kim, Young Do;Park, Sungeun;Kim, Dongwhan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.122.1-122.1
    • /
    • 2011
  • Phosphorus is known to pile-up at the silicon surface when it is thermally oxidized. A thin layer, about 40nm thick from the silicon surface, is created containing more phosphorus than the bulk of the emitter. This layer has a gaussian profile with the peak at the surface of the silicon. In this study the pile-up effect was studied if this layer can act as a front surface field for solar cells. The effect was also tested if its high dose of phosphorus at the silicon surface can lower the contact resistance with the front metal contact. P-type wafers were first doped with phosphorus to create an n-type emitter. The doping was done using either a furnace or ion implantation. The wafers were then oxidized using dry thermal oxidation. The effect of the pile-up as a front surface field was checked by measuring the minority carrier lifetime using a QSSPC. The contact resistance of the wafers were also measured to see if the pile-up effect can lower the series resistance.

  • PDF

Effect of $NH_3$ on the Synthesis of Carbon Nanotubes Using Thermal Chemical Vapor Deposition

  • Cho, Hyun-Jin;Jang, In-Goo;Yoon, So-Jung;Hong, Jin-Pyo;Lee, Nae-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1219-1224
    • /
    • 2006
  • This study investigates the effect of $NH_3$ gas upon the growth of carbon nanotubes (CNTs) using thermal chemical vapor deposition. It is considered that the CNT synthesis occurs mainly through two steps, clustering of catalyst particles and subsequent growth of CNTs. We thus introduced $NH_3$ during either an annealing or growth step. When $NH_3$ was fed only during annealing, CNTs grew longer and more highly crystalline with diameters unchanged. An addition of $NH_3$ during growth, however, resulted in shorter CNTs with lower crystallinity while increased their diameters. Vertically aligned, highly populated CNT samples showed poor field emission characteristics, leading us to apply post-treatments onto the CNT surface. The CNTs were treated by adhesive tapes or etched back by dc plasma of $N_2$ to reduce the population density and the radius of curvatures of CNTs. We discuss the morphological changes of CNTs and their field emission properties upon surface treatments.

  • PDF

A Study on the Operating Characteristics of Commercial Frequency Plasma Jet Torch (상용 주파수 (60Hz) Plasma Jet Torch의 동작특성에 관한 연구)

  • 전춘생;정재웅
    • 전기의세계
    • /
    • v.24 no.1
    • /
    • pp.75-85
    • /
    • 1975
  • In order to develop the commercial frequency (60Hz) plasma torch of small capacity for material cutting, welding and other industrial heating, the A.C plasma jet generator of non-transfered type is made domestically and the electrode configurations of plasma torch are composed of two kinds of electrodes W-C and W-Cu, combined by thermal emission and field emission electrode materials. In this paper, the characteristics of input power, thermal efficiency, electrode consumption, the flame and forms of arc voltage and arc current for A.C plasma torch are investigated in relation to such variables as arc current, argon flow and magnetic field intensity to obtain the basic design data necessary to A.C plasma jet generator. The result are as follows; (1)The input power, thermal efficiency and electrode consumption are influenced greatly by argon flow, magnetic field intensity and nozzle materials. (2)A.C arc voltage and current are non-symmetrial, involving D.C Component. Due to this current of D.C Component, transformer core is saturated and a large abnormal current flows into the primary winding coil. In order to prevent this abnormal current flow, a condenser must be connected in series to the main discharge circuit. (3)The stability and sharpness of jet flame are improved more in the torch of W-C electrode configuration than in the torch of W-Cu electrode configuration.

  • PDF

Evaluation of Energy Consumption through Field Measurement at the Apartment Housing Unit Using Dynamic Flow Rate Balancing (실물실험을 통한 다이나믹 유량밸런싱 적용 공동주택 세대의 에너지소비량 평가)

  • Ryu, Seong-Ryong;Cheong, Chang-Heon;Cho, Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.15-20
    • /
    • 2016
  • Even though the control device of the heating system works well, insufficient water flow rates can degrade control performance and thermal comfort. The water flow rate should be adjusted appropriately to cope with the heating load of each zone. In order to solve these problems, a new balancing concept 'dynamic balancing' was proposed where a balancing valve opening can be automatically modulated according to the heating condition of the room. This study analyzed the effects of dynamic balancing upon indoor thermal environment and energy consumption in a radiant floor heating system through field measurement. Under part-load conditions, the use of a dynamic balancing is a more effective method to reduce energy consumption and to prevent a cavitation. Dynamic balancing is able to help boost the temperature of a room in the start-up period.

Thermal Stress Analysis by Field Data Conversion between FDM and FEM (FDM과 FEM의 해석 데이터 변환에 의한 탄소성 열응력 해석)

  • Kwahk, S.Y.;Cho, C.D.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.4
    • /
    • pp.228-234
    • /
    • 2001
  • The present study was an attempt for systematic data conversion between FDM and FEM in order to evaluate the thermal stress distribution during quenching process. It has been generally recognized that FDM is efficient in flow and temperature analysis and FEM in that of stress. But it induced difficulty and tedious work in analysis that one uses both FDM and FEM to take their advantages because of the discrepancy of nodes between analysis tools. So we proposed field data conversion procedure from FDM to FEM in 3-dimensional space, then applied this procedure to analysis of quenching process. The simulation procedure calculates the distributions of temperature and microstructure using FDM and microstructure evolution equations of diffusion and diffusionless transformation. FEM was used for predicting the distributions of thermal stress. The present numerical code includes coupled temperaturephase transformation kinetics and temperature-microstructure dependent material properties. Calculated results were compared with previous experimental data to verify the method, which showed good agreements.

  • PDF