• 제목/요약/키워드: Thermal enhancement ratio

검색결과 69건 처리시간 0.03초

응축용 특수 전열관의 열전달 특성에 관한 연구 (Experimental Study on Condensation Heat Transfer Characteristics of Special Heat Transfer Tubes)

  • 한규일;박종운;권영철;조동현
    • 설비공학논문집
    • /
    • 제13권9호
    • /
    • pp.827-835
    • /
    • 2001
  • In this study, condensation heat transfer characteristics were conducted with special heat transfer tubes of SH-C type. Experiments were carried out the saturated vapor temperature of 334K and the wall subcooling of 1.5-4.5K. The refrigerant was R-113 and the enhanced tubes used in the present study were SH-CDR, SH-CYR and SH-CHR. The experimental results showed that the condensation heat transfer coefficients of SH-C type tubes were about 23-66% higher than those of a low integral-fin tube. It was visualized that the condensed liquid on the outer surface of SH-C type tubes flowed continuously down unlike a low integral-fin tube and a plain tube, due to a 3-D extending fin on the outer surface of SH-C type tubes. As a result, the thermal resistance of the condensed liquid decreased and the heat transfer coefficient increased. Also, the enhancement ratio of SH-CDR tube was the highest, and it was about 9-11 times as compared to that of a plain tube.

  • PDF

방사선조사와 온열요법이 백서신에 미치는 조직 변화에 관한 실험적 연구 (An Experimental Study on the Effects of Hyperthermia and Irradiation on the Rat's Kidney)

  • 유명희;이경자;이정식
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.157-169
    • /
    • 1989
  • Radiological and clinical evidences indicate that hyperthermia combined with irradiation produce a significant improvement in therapeutic effect of cancer The experiences obtained from 90 rats' kidney A single dose of irradiation ranged from 6Gy, 8Gy and 10Gy was delivered on the rat's kidney. The combined therapy group had the same irradiation after hyperthermia at $42\~44^{\circ}C$ for 30 minutes. Microscopic examination and calculation of thermal enhancement ratio were carried out, and the results were as follows: 1. In the group of hyperthermia alone, there were moderate glomerular congestion and mild tubular degeneration on light microscopic examination. 2. In the group of irradiation alone, tubular degeneration was noted in 6Gy irradiation and its severity was increased along with radiation dose. 3. In the group of hyperthermia combined with irradiation, tubular degeneration and necrosis were appeared in 6Gy and 10Gy irradiation, respectively. 4. On electron microscopic examination, proximal convoluted tubular and glomerular changes in irradiation group were similar to that of combined with hyperthermia, and its severity was increased along with observation periods. 5. Thermal enhancement ratio (TER) was 1.0 after evaluation of histipathologic changes in rat's kidney, with combination therapy.

  • PDF

V 형 rib과 dimple로 구성된 SAH 덕트에서의 총괄 열성능에 대한 수치적 연구 (Numerical study on overall thermal performance in SAH duct with compound roughness of V-shaped ribs and dimples)

  • 아닐 쿠마르;김만회
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.43-55
    • /
    • 2015
  • This paper presents the thermal hydraulic performance of a three dimensional rib-roughened solar air heater (SAH) duct with the one principal wall subjected to uniform heat flux. The SAH duct has aspect ratio of 12.0 and the Reynolds number ranges from 2000 to 12000. The roughness has relative rib height of 0.045, ratio of dimple depth to print diameter of 0.5 and rib pitch ratio of 8.0. The flow attack angle is varied from $35^{\circ}$ to $70^{\circ}$. Various turbulent flow models are used for the heat transfer and fluid flow analysis and their results are compared with the experimental results for smooth surfaces. The computational fluid dynamics (CFD) results based on the renormalization k-epsilon model are in better outcomes compared with the experimental data. This model is used to calculate heat transfer and fluid flow in SAH duct with the compound roughness of V-shaped ribs and dimples. The overall thermal performance based on equal pumping power is found to be the highest (2.18) for flow attack angle of $55^{\circ}$. The thermo-hydraulic performance for V-pattern shaped ribs combined with dimple ribs is higher than that for dimple rib shape and V-pattern rib shape air duct.

저온열교환기 효율 향상을 위한 탄소나노유체의 특성 비교 연구 (A Comparative Study on the Characteristics of Carbon Nanofluids for Efficiency Enhancement of Low Temperature Heat Exchanger)

  • 박성식;안응진;이경수;박윤철;김남진
    • 에너지공학
    • /
    • 제20권3호
    • /
    • pp.209-215
    • /
    • 2011
  • 본 연구에서는 저온 열교환기 효율 향상을 위하여 상온($25^{\circ}C$)과 저온($10^{\circ}C$)에서 탄소나노유체와 산화탄소나 노유체의 열전도도와 점도를 측정하였다. 탄소나노유체는 다중벽 탄소나노튜브에 계면활성제 SDS 100 wt%, 고분자 화합물 PVP 300 wt%를 각각 혼합한 뒤 증류수에 초음파 분산하여 제조하였고, 산화탄소나노유체는 산화 처리된 다중벽 탄소나노튜브를 증류수에 초음파 분산하여 제조하였다. 탄소나노유체의 열전도도는 비정상 열선법을 사용하여 측정하였으며, 점도는 회전형 디지털 점도계를 사용하여 측정하였다. 그 결과 같은 혼합비율과 온도에서 다른 탄소나노유체들 보다 산화탄소나노유체의 열전도도가 가장 높게 측정되었고, 점도는 가장 낮게 측정되었다.

Thermal buckling of rectangular sandwich plates with advanced hybrid SMA/CNT/graphite/epoxy composite face sheets

  • Saeed Kamarian;Jung-Il Song
    • Advances in nano research
    • /
    • 제14권3호
    • /
    • pp.261-271
    • /
    • 2023
  • The present study follows three main goals. First, an analytical solution with high accuracy is developed to assess the effects of embedding pre-strained shape memory alloy (SMA) wires on the critical buckling temperatures of rectangular sandwich plates made of soft core and graphite fiber/epoxy (GF/EP) face sheets based on piecewise low-order shear deformation theory (PLSDT) using Brinson's model. As the second goal, this study compares the effects of SMAs on the thermal buckling of sandwich plates with those of carbon nanotubes (CNTs). The glass transition temperature is considered as a limiting factor. For each material, the effective ranges of operating temperature and thickness ratio are determined for real situations. The results indicate that depending on the geometric parameters and thermal conditions, one of the SMAs and CNTs may outperform the other. The third purpose is to study the thermal buckling of sandwich plates with advanced hybrid SMA/CNT/GF/EP composite face sheets. It is shown that in some circumstances, the co-incorporation of SMAs and CNTs leads to an astonishing enhancement in the critical buckling temperatures of sandwich plates.

압축기 출구 물분사가 있는 재생 가스터빈 시스템의 엑서지 해석 (Exergy Analysis of Regenerative Gas Turbine Systems with Afterfogging)

  • 김경훈;고형종;김세웅
    • 한국산업융합학회 논문집
    • /
    • 제13권1호
    • /
    • pp.31-39
    • /
    • 2010
  • An exergy analysis is carried out for the regenerative gas turbine cycle which has a potential of enhanced thermal efficiency and specific power owing to the more possible water injection than that of inlet fogging under the ambient conditions. Using the analysis model in the view of the second law of thermodynamics, the effects of pressure ratio, water injection ratio and ambient temperature are investigated on the performance of the system such as exergetic efficiency, heat recovery ratio of recuperator, exergy destruction or loss ratios, and on the optimal conditions for maximum exergy efficiency. The results of computation for the typical cases show that the regenerative gas turbine system with afterfogging can make a notable enhancement of exergy efficiency.

  • PDF

수소기관의 수소연료의 희석에 의한 역화억제효과에 관한 연구 (A Study on Enhancement of Combustion Performance by Dilution of Hydrogen in Heavy-Duty Hydrogen Engine)

  • 김서영;김윤영;김용태;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.348-354
    • /
    • 2004
  • Hydrogen gas has several merits such as lower ignition energy, wide flammability and shorter quenching distance. It leads to high thermal efficiency but backfire occurrence. In this study, feasibility of expansion of BFL(Back-Fire Limit) equivalence ratio and combustion characteristics by a dilution of hydrogen fuel are experimently examined by using experimental heavy duty single cylinder hydrogen fueled engine. As results, it is found that BFL equivalence ratio is expanded to rich range and torque is increased.

흰쥐의 장조직에 X-선 조사와 마이크로파 온열요법의 효과에 관한 실험적 연구 (An Experimental Study on the Effectiveness of Microwave Hyperthermia Combined with Radiation on the Small and Large Intestine in rats)

  • 안경숙;이경자;이정식
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.83-95
    • /
    • 1987
  • 온열요법은 조직에 $40^{\circ}C-44^{\circ}C$의 열을 가함으로서 방사선에 저항성이 큰 DNA합성기의 세포 및 pH가 낮은 세포에 민감하게 작용하는 생물학적 효과를 암 치료에 이용하는 것이다. 그러나 온열요법은 방사선과의 병행요법에 의하여 발생되는 열증강율 및 치료 이득이 방사선량, 열량, 온도, 가열시간, 온도분포, 조사시간 등에 민감하고 변화가 많으므로 객관적인 치료효과와 통일된 치료방법을 결정하기가 어렵다. 저자는 2450MHz, 100watt의 마이크로파 온열기구와 조직등가인 팬톱을 직접제작하여 예비측정을 통해 방열 조사조건과 방법을 결정한 후 생물학적 반응을 관찰하기 위하여 102마리 흰쥐 소장 및 대장의 조직학적 면화를 관찰하고 열증강율에 따른 효과를 비교 평가하여 다음과 같은 결론을 얻었다. 1 온열요법 단독으로는 소장과 대장의 조직학적 면화는 볼 수 없었다. 2. 방사선 조사 단독군과 병행군에서 소장 및 대장의 점막상피 괴사는 방사선 조사 6Gy에서 관찰되었으며 방사선량의 증가와 관찰시간 경과에 따라 그 정도가 심하여졌다. 3. 방사선 조사 단독군과 병행군에서 소장 및 대장의 근육층의 괴사는 방사선 조사 10Gy에서 관찰되기 시작하였으며 관찰시간의 경과에 따라 그 정도가 심하여졌다. 4. 방사선 조사와 온열요법 병행군에서 소장과 대장의 조직학적 변화(점막상피와 근육층의 괴사)를 관찰하여 열증강율은 증가되지 않았다.

  • PDF

Heat transfer enhancement of nanofluids in a pulsating heat pipe for heat dissipation of LED lighting

  • Kim, Hyoung-Tak;Bang, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1200-1205
    • /
    • 2014
  • The effect of nanofluids on the heat transfer performance of a pulsating heat pipe has been experimentally investigated. Water-based diamond nanofluid and aluminium oxide ($Al_2O_3$) nanofluid were tested in the concentration range of 0.5-5%. The pulsating heat pipe was constructed using clear Pyrex tubes of 1.85 mm in inner diameter in order to visualize the pulsating action. The total number of turns was eight each for heated and cooled parts. The supply temperatures of heating water and cooling water were fixed at $80^{\circ}C$ and $25^{\circ}C$ respectively. The liquid charging ratio of the nanofluid was 50-70%. The test results showed that the case of 5% concentration of diamond nanofluid showed 18% increase in heat transfer rate compared to pure water. The case of 0.5% concentration of $Al_2O_3$ nanofluid showed 24% increase in heat transfer rate compared to pure water. But the increase of $Al_2O_3$ nanofluid concentration up to 3% did not show further enhancement in heat transfer. It is also observed that the deposited nanoparticles on the tube wall played a major role in enhanced evaporation of working fluid and this could be the reason for the enhancement of heat transfer by a nanofluid, not the enhanced thermal conductivity of the nanofluid.

레이저 스페클간섭법에 의한 STS430의 열팽창계수 측정 (Thermal Expansion Coefficient Measurement of STS430 by Laser Speckle Interferometry)

  • 김경석;이항서;정현철;양승필
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.29-33
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,000$^{\circ}C$. Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 800$^{\circ}C$. There needs to measure the data up to 800$^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000$^{\circ}C$. In previous studies related to thermal strain analysis, the quantitative results are not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,000$^{\circ}C$and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow 600$^{\circ}C$ however, there is some difference up to 600$^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 800$^{\circ}C$. The reason is the phase transformation of STS430 probably begins at 800$^{\circ}C$.

  • PDF