• 제목/요약/키워드: Thermal energy storage

검색결과 714건 처리시간 0.033초

태양열 냉.난방시스템의 열성능 분석 (Analysis of Thermal Performance of a Solar Heating & Cooling System)

  • 곽희열;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권4호
    • /
    • pp.43-49
    • /
    • 2008
  • The purpose of this study is to present the simulation results and an overview of the performance assessment of a solar heating & cooling system by means of the $200m^2$ evacuated tube solar collector. The simulation was carried out using the thermal simulation code TRNSYS with new model of a single-effect LiBr/$H_{2}O$ absorption chiller developed by this study. The calculation was performed for yearly long-term thermal performance and for two design factors: the solar hot water storage tank and the cold water storage tank. As a result, it was anticipated that the yearly mean system efficiency is 46.7% and the solar fraction for the heating, cooling and hot water supply are about 84.4 %, 41.7% and 72.4%, respectively.

Solar Energy-Latent Heat Storage System for Greenhouse Heating

  • Song, Hyun-Kap;Ryou, Young-Sun
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.453-472
    • /
    • 1993
  • Two types of solar energy-latent heat storage system have been developed to minimize the fossil fuel consumption and maximize the solar energy utilization in greenhouse heating during the winter season. The one was installed on the greenhouse floor, and the other in the underground of the greenhouse . Sodium suphate decahydrate was selected as a highly concentrative solar energy storage medium and its unstable thermophysicla properties were adjusted by some additives. Thermal efficiency of them was analyzed by numerical and experimental method.

  • PDF

공기순환구조를 갖는 축열지붕의 열전달해석 (Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System)

  • 신우철;박석현;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

수치 모델링 기법을 이용한 개별 대수층 축열 시스템 활용성 예비 평가 (Preliminary Feasibility Study of Separated Aquifer Thermal Energy Storage System using Numerical Method)

  • 김종찬;김형수;이영민
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.556-560
    • /
    • 2009
  • 개별 대수층에 냉수와 온수를 저장하여 수자원과 냉난방 열원으로 활용하는 방안에 대한 평가를 지열-지하수 부정류 모델링을 통해 수행하였다. 저장 및 회수 가동 시간이 증가함에 따라서 각각의 대수층 내에 온열과 냉열이 축열되는 현상이 확인되었으며, 지하수 유동에 의해 축열된 수체가 지하수 흐름방향으로 이동하는 현상을 확인 하여 지하수 유동이 축열 정도를 결정하는 요인이 될 수 있음을 확인하였다. 설정된 모델에 대하여, 두 개의 개별 대수층 사이의 열 간섭은 거의 없는 것으로 나타났다. 주입과 양수의 가동 횟수가 증가되면, 대수층 축열 효과는 증대되는 것으로 나타났다. 열-지하수 모델링을 통한 온도 예측은 실제 냉난방의 효율성을 결정짓는 수온을 정량적으로 계산할 수 있는 유용한 기술로 평가됨과 더불어, 수자원의 지하 저장을 통해 효율적으로 물을 확보하고 관리할 수 있는 방안이 될 수 있을 것으로 기대된다.

  • PDF

지하수류가 대수층 열저장 시스템의 성능에 미치는 영향(3) (The Influence of Groundwater Flow on the Performance of an Aquifer Thermal Energy Storage (ATES) System)

  • 한정상;이주현;김영식;이광진;홍경식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권4호
    • /
    • pp.9-26
    • /
    • 2017
  • When a warm well located downgradient is captured by cold thermal plume originated from an upgradient cold well, the warm thermal plume is pushed further downgradient in the direction of groundwater flow. If groundwater flow direction is parallel to an aquifer thermal energy storage (ATES), the warm well can no longer be utilized as a heat source during the winter season because of the reduced heat capacity of the warm groundwater. It has been found that when the specific discharge is increased by $1{\times}10^{-7}m/s$ in this situation, the performance of ATES is decreased by approximately 2.9% in the warm thermal plume, and approximately 6.5% in the cold thermal plume. An increase of the specific discharge in a permeable hydrogeothermal system with a relatively large hydraulic gradient creates serious thermal interferences between warm and cold thermal plumes. Therefore, an area comprising a permeable aquifer system with large hydraulic gradient should not be used for ATES site. In case of ATES located perpendicular to groundwater flow, when the specific discharge is increased by $1{\times}10^{-7}m/s$ in the warm thermal plume, the performance of ATES is decreased by about 2.5%. This is 13.8% less reduced performance than the parallel case, indicating that an increase of groundwater flow tends to decrease the thermal interference between cold and warm wells. The system performance of ATES that is perpendicular to groundwater flow is much better than that of parallel ATES.

상변화를 동반하는 열전달과 축열에 관한 연구 (비정상열선법에 의한 축열구율의 측정) (Phase Change Heat Transfer and Storage of Thermal Energy -Measurement of Thermal conductivity by Non-steady Hot Wire Method-)

  • 이택식;노승탁
    • 기계저널
    • /
    • 제16권2호
    • /
    • pp.116-121
    • /
    • 1976
  • Non-steady hot wire method was adopted to measure thermal coductivity of paraffin wax in the phases of liquid and solid for the utilization of thermal energy storage. The instrument was tested with the measurement of thermal conductivity of water at various temperatures. The reproducibility of the instrumetn was found to be ${\pm}2%$, in which the results for water agree with the literature values. The thermal conductivity of paraffin wax varies from 0.177 W/m C to 0.236 W/m C when the phase changes from liquid to solid near the melting temperature.

  • PDF

냉매사이클과 열매체유 순환을 활용한 액화공기에너지저장 시스템 공정모사 연구 (Simulation Study on Liquid Air Energy Storage (LAES) System using Dual Refrigeration Cycles and Thermal Oil Circulation)

  • 장순남;박종포
    • 한국가스학회지
    • /
    • 제22권4호
    • /
    • pp.63-73
    • /
    • 2018
  • 잉여전력 등을 활용한 에너지저장시스템 분야에 기술에 관심이 집중되고 혁신적인 기술진보가 이루어지고 있다. 다양한 에너지저장시스템 분야 중 가스액화 방식을 활용한 액화공기에너지저장 시스템은 상당히 성숙된 기술로 알려져 있고, 높은 단위 에너지 밀도와 설치에 따른 지형적 제약이 거의 없으며 수명이 긴 저장 시스템이라는 많은 장점에도 불구하고, 단일공정 (공기액화-재기화 사이클)의 낮은 사이클 효율로 인해 상업화에 한계가 있었다. 본 연구에서는 낮은 사이클 효율을 개선하고자 2종류의 냉매(R-600a 와 메탄올)을 이용한 냉매사이클을 공기 액화 공정에 활용하여 사이클 효율을 향상시키고, 공기 압축시 발생하는 압축열을 열매체유 순환 사이클에 이용하여 이를 액화공기 재기화 공정의 터빈 입구 온도를 높이는데 활용하여 전력생산량을 추가적으로 증가시킴으로써 사이클 효율을 획기적으로 향상시킬 수 있는 가능성을 Aspen HYSYS 공정 모사 프로그램을 활용하여 확인하였다.

태양열과 재열기를 사용한 VI heat pump의 성능 특성에 관한 연구 (Heating Performance Characteristics of Heat Pump with VI cycle using Re-Heater and Solar-Assisted)

  • 이진국;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제35권6호
    • /
    • pp.25-33
    • /
    • 2015
  • In this study, heating performance of the air-cooled heat pump with vapor-injection (VI) cycles, re-heater and solar heat storage tank was investigated experimentally. Devices used in the experiment were comprised of a VI compressor, re-heater, economizer, variable evaporator, flat-plate solar collector for hot water, thermal storage tank, etc. As working fluid, refrigerant R410A for heat pump and propylene glycol (PG) for solar collector were used. In this experiment, heating performance was compared by three cycles, A, B and C. In case of Cycle B, heat exchange was conducted between VI suction refrigerant and inlet refrigerant of condenser by re-heater (Re-heater in Fig. 3, No. 3) (Cycle B), and Cycle A was not use re-heater on the same operating conditions. In case of Cycle C, outlet refrigerant from evaporator go to thermal storage tank for getting a thermal energy from solar thermal storage tank while re-heater also used. As a result, Cycle C reached the target temperature of water in a shorter time than Cycle B and Cycle A. In addition, it was founded that, as for the coefficient of heating performance($COP_h$), the performance in Cycle C was improved by 13.6% higher than the performance of Cycle B shown the average $COP_h$ of 3.0 and by 18.9% higher than the performance of Cycle A shown the average $COP_h$ of 2.86. From this results, It was confirmed that the performance of heat pump system with refrigerant re-heater and VI cycle can be improved by applying solar thermal energy as an auxiliary heat source.

슬래브축열의 최적제어방책에 관한 연구 -평가요소로 복사열의 고려 유무에 의한 차이- (A Study on the Optimal Control Strategy of Air-Conditioning System with Slab Thermal Storage - The Difference by the Presence of Radiant Heat as a Criterion Factor -)

  • 정재훈;신영기
    • 설비공학논문집
    • /
    • 제18권4호
    • /
    • pp.287-296
    • /
    • 2006
  • In this paper, optimal control strategy of the air-conditioning system with slab thermal storage was investigated based on the optimal control theory. An optimal heat output to the plenum chamber and the air-conditioned room was determined based on two kinds of criterion functions. The first one requires small deviation in room air temperature from a set-point value and low energy consumption. It is shown that the optimized control is to store heat through the whole storage time and to increase storage rate gradually with time. As the second case, a criterion that both a deviation of operative temperature from a set-point temperature and the energy consumption should be minimized was adopted. The room air temperature was a little high and the cooling load during storage time was reduced, compared with the results when a criterion function considering only the room air temperature is used.

성층축열조의 성능에 대한 설계인자의 영향 (Effect of Design Factors on the Performance of Stratified Thermal Storage Tank)

  • 정재동;박주혁;조성환
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1077-1083
    • /
    • 2004
  • This study is to systematically analyze the effect of various kinds of design factors on the performance of stratified thermal storage tank. Taguchi method, known as a very reasonable tool in the parametric study, is employed in the present work. Three dimensional unsteady numerical experiment is conducted for 4 design parameters of stratified thermal storage tank: inlet Reynolds number, Froude number, diffuser size d with 3 levels (Re=400, 800, 1200, Fr=0.5, 1.0, 2.0 and d=150 mm, 200mm, 300 mm) and diffuser shape with 2 levels. Orthogonal array $L_{18}(2{\times}3^7)$ is adopted for the analysis of variance. The result gives quantitative estimation of the various design parameters affecting the performance and helps to select the main factors for the optimum design of stratified thermal storage tank. Reynolds number is found to be the most dominant parameter and the diffuser shape plays significant role on the performance of stratified thermal storage tank. Based on this finding, the prior questions on the contribution of the diffuser shape proposed by the authors become clear. The optimum condition for the performance is a set of d=300mm, Re=800, and radial regulated plate diffuser. Conformation test shows the repeatability in the analysis and $1.3\%$ difference between the estimated thermocline thickness and that of numerical result.