• Title/Summary/Keyword: Thermal controls

Search Result 118, Processing Time 0.027 seconds

Backstepping Control for Multi-Machine Web Winding System

  • Bouchiba, Bousmaha;Hazzab, Abdeldjebar;Glaoui, Hachemi;Med-Karim, Fellah;Bousserhane, Ismail Khalil;Sicard, Pierre
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.59-66
    • /
    • 2011
  • This work treat the modeling and simulation of non-linear dynamic behavior of a web winding process during traction. We designate by a winding process any system applying the cycles of unwinding, transport, treatment, and winding to various flat products. This system knows several constraints, such as the thermal effects caused by the frictions, and the mechanical effects provoked by metal elongation, that generates dysfunctions due to the influence of the process conditions. Several controllers are considered, including Proportional-integral (PI) and Backstepping control. This paper presents the study of Backstepping controls strategy of the winding system. Our winding system is simulated in MATLAB SIMULINK environment, the results obtained illustrate the efficiency of the proposed control with no overshoot, and the rising time is improved with good disturbances rejections comparing with the classical control law.

Effects of Microwaves on the Germination of Weed Seeds

  • Sahin, Hasan
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.304-309
    • /
    • 2014
  • Purpose: Weeds cause significant losses in agricultural production. In this study, we investigated the effect of microwaves on the germination rates of cress and arugula seeds to determine whether microwaves could be developed as an effective alternative to conventional chemical-based herbicides. Methods: Seeds were planted at equal depths (8-10 mm) in a soil-turf mixture, and seeds were exposed to microwaves for 126 s, 70 s, and 50 s in a device constructed specifically for this study. A microwave tunnel was built using a variable speed conveyor belt and 4 magnetrons with a combined output power of 2.8 kW. Seeds that were not exposed to microwaves were germinated with regulated irrigation, temperature, and humidity controls in parallel with the treated seeds, and the germination rates were compared among the treatment groups. Results: We found that the exposure of cress and arugula seeds to microwaves for 126 s inhibited germination close to 100%. Cress seeds treated with microwaves for 50 s showed 95% germination compared to 65% germination of the untreated cress seeds. Conclusions: We predict that the thermal effect of microwave energy affects the germination ratio and germination rate of seeds.

Numerical analysis of spalling of concrete cover at high temperature

  • Ozbolt, Josko;Periskic, Goran;Reinhardt, Hans-Wolf;Eligehausen, Rolf
    • Computers and Concrete
    • /
    • v.5 no.4
    • /
    • pp.279-293
    • /
    • 2008
  • In the present paper a 3D thermo-hygro-mechanical model for concrete is used to study explosive spalling of concrete cover at high temperature. For a given boundary conditions the distribution of moisture, pore pressure, temperature, stresses and strains are calculated by employing a three-dimensional transient finite element analysis. The used thermo-hygro-mechanical model accounts for the interaction between hygral and thermal properties of concrete. Moreover, these properties are coupled with the mechanical properties of concrete, i.e., it is assumed that the mechanical properties (damage) have an effect on distribution of moisture (pore pressure) and temperature. Stresses in concrete are calculated by employing temperature dependent microplane model. To study explosive spalling of concrete cover, a 3D finite element analysis of a concrete slab, which was locally exposed to high temperature, is performed. It is shown that relatively high pore pressure in concrete can cause explosive spalling. The numerical results indicate that the governing parameter that controls spalling is permeability of concrete. It is also shown that possible buckling of a concrete layer in the spalling zone increases the risk for explosive spalling.

A Study on the State feedback with Integral Control for a Variable Air Volume Unit (가변 풍량 유닛에 대한 적분기를 가진 상태 궤환 제어에 관한 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.9-14
    • /
    • 2000
  • State feedback with integral control for a variable air volume(VAV) unit which is recently taken notice of for the energy efficiency and saving in the building is studied to investigate the performance of the digital control methodology for the possible practical application. The digital controller which acquires the targat zone temperature and the air flow rate of the supplied air to the zone controls the opening of the damper in the VAV unit. Simulation results are performed for the conditions including reference changes and external thermal variations. In the simulation. simplified conditioned zone and the damper actuator modelling is considered. and relationships between controller gain Parameters and the system dynamics are investigated.

  • PDF

Application of Artificial Neural Network for Optimum Controls of Windows and Heating Systems of Double-Skinned Buildings (이중외피 건물의 개구부 및 난방설비 제어를 위한 인공지능망의 적용)

  • Moon, Jin-Woo;Kim, Sang-Min;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.8
    • /
    • pp.627-635
    • /
    • 2012
  • This study aims at developing an artificial neural network(ANN)-based predictive and adaptive temperature control method to control the openings at internal and external skins, and heating systems used in a building with double skin envelope. Based on the predicted indoor temperature, the control logic determined opening conditions of air inlets and outlets, and the operation of the heating systems. The optimization process of the initial ANN model was conducted to determine the optimal structure and learning methods followed by the performance tests by the comparison with the actual data measured from the existing double skin envelope. The analysis proved the prediction accuracy and the adaptability of the ANN model in terms of Root Mean Square and Mean Square Errors. The analysis results implied that the proposed ANN-based temperature control logic had potentials to be applied for the temperature control in the double skin envelope buildings.

Performance tests on the ANN model prediction accuracy for cooling load of buildings during the setback period (셋백기간 중 건물 냉방시스템 부하 예측을 위한 인공신경망모델 성능 평가)

  • Park, Bo Rang;Choi, Eunji;Moon, Jin Woo
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.83-88
    • /
    • 2017
  • Purpose: The objective of this study is to develop a predictive model for calculating the amount of cooling load for the different setback temperatures during the setback period. An artificial neural network (ANN) is applied as a predictive model. The predictive model is designed to be employed in the control algorithm, in which the amount of cooling load for the different setback temperature is compared and works as a determinant for finding the most energy-efficient optimal setback temperature. Method: Three major steps were conducted for proposing the ANN-based predictive model - i) initial model development, ii) model optimization, and iii) performance evaluation. Result:The proposed model proved its prediction accuracy with the lower coefficient of variation of the root mean square errors (CVRMSEs) of the simulated results (Mi) and the predicted results (Si) under generally accepted levels. In conclusion, the ANN model presented its applicability to the thermal control algorithm for setting up the most energy-efficient setback temperature.

Design and Implementation of Automatic Control System in Room using Sensor (센서를 이용한 자동 실내 온도 제어시스템 설계 및 구현)

  • Jeong, Gyu-Tae;Lee, Eun-Jin;Kim, Heung-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.326-328
    • /
    • 2015
  • Function of the window of the building is an environment of the room through the entry of solar radiation. It is vulnerable to significant energy conservation off the thermal efficiency. Also this summer, cooling costs are weighted because of excessive solar radiation. In this paper, we develop a windows automatic control system to use the indoor environmental information, such as home temperature, humidity, light intensity, solar radiation. The system collects the indoor environment information using a variety of sensor, using the collected information, and controls the motor to the system to control the window.

  • PDF

The Effect of Residence Time and Heat Loss on NOx Formation Characteristics in the Downstream Region of CH4/Air Premixed Flame (CH4/Air 예혼합화염의 하류영역에서 체류시간 및 열손실에 의한 NOx의 생성특성)

  • Hwang, Cheol-Hong;Hyun, Sung-Ho;Tak, Young-Jo;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.99-108
    • /
    • 2007
  • In this study, the NOx formation characteristics of one-dimensional $CH_4$/Air premixed flame using detailed-kinetic chemistry are examined numerically. The combustor length and the amount of heat loss are varied to investigate the effect of residence time and heat loss on the NOx formation in a post-flame region. In the flame region, NO is mainly produced by the Prompt NO mechanism including $N_2$O-intermediate NO mechanism over all equivalence ratios. However, thermal NO mechanism is more important than Prompt NO mechanism in the post-flame region. In the case of adiabatic condition, the increase of combustor length causes the remarkable increase of NO emission at the exit due to the increase of residence time. On the other hand, NO reaches the equilibrium state in the vicinity of flame region, considering radiation and conduction heat losses. Furthermore the NO, in the case of $\phi$=1.2, is gradually reduced in the downstream region as the heat loss is increased. From these results, it can be concluded that the controls of residence time and heat loss in a combustor should be recognized as an important NOx reduction technology.

Advanced approach to information security management system utilizing maturity models in critical infrastructure

  • You, Youngin;Oh, Junhyoung;Kim, Sooheon;Lee, Kyungho
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.10
    • /
    • pp.4995-5014
    • /
    • 2018
  • As the area covered by the CPS grows wider, agencies such as public institutions and critical infrastructure are collectively measuring and evaluating information security capabilities. Currently, these methods of measuring information security are a concrete method of recommendation in related standards. However, the security controls used in these methods are lacking in connectivity, causing silo effect. In order to solve this problem, there has been an attempt to study the information security management system in terms of maturity. However, to the best of our knowledge, no research has considered the specific definitions of each level that measures organizational security maturity or specific methods and criteria for constructing such levels. This study developed an information security maturity model that can measure and manage the information security capability of critical infrastructure based on information provided by an expert critical infrastructure information protection group. The proposed model is simulated using the thermal power sector in critical infrastructure of the Republic of Korea to confirm the possibility of its application to the field and derive core security processes and goals that constitute infrastructure security maturity. The findings will be useful for future research or practical application of infrastructure ISMSs.

Oven Temperature Control by Integral - Cycle Binary Rate Modulation Technique

  • Tipsuwanporn, V.;Piyarat, W.;Chochai, N.;Jamjan, K.;Paraken, Y.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.278-280
    • /
    • 1999
  • This paper proposes controlling of temperature in an oven by using 4 bits Integral - Cycle Binary Rate Modulation (IBRM) method and ac line with frequency 50 Hz. Microcontroller MCS-51 controls IBRM according to Proportional Integral controller (PI) function. Discrete signals are used in the system modeled by using Ziegler Nichols principle for analyzing the stability before designing the system. This procedure makes it easy to investigate system response. The system is implemented by 4 bits digital circuit which gives 320 patterns of ac signal fur controlling the generation of energy for 3,000 watts thermal coil every 20 ms of each cycle. We divide scan time (Ts$\sub$n/) in to 20 intervals, 1 ms interval is selected to generate 16 patterns IBRM. Because of this method gives the ripple lower than 2% it generates less noise fur system. Moreover, we can consider whole system from the time model of control procedure and IBRM algorithm at 40-200$^{\circ}C$ with ${\pm}$ 1$^{\circ}C$ error in the 1 cubic meter oven.

  • PDF