• 제목/요약/키워드: Thermal comfort

검색결과 694건 처리시간 0.022초

기류유인팬을 이용한 새 국립중앙박물관 로튠다에서의 열환경 평가 (Evaluation on Thermal Environment Installed Ventilating Fans in the Rotunda at New National Museum of Korea)

  • 이승철
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.303-309
    • /
    • 2004
  • In order to improve thermal comfort in the Rotunda, which is high and wide visiting space of the new national museum of Korea, eight ventilating fans were installed near the ceiling of Rotunda. It has been analyzed thermal comfort of Rotunda with/without ventilating fans by numerical simulation. To evaluate thermal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that temperature distribution of the case with fans is closer to target temperature than the case with-out fans at the breathing zone. In the case without fans, thermal stratification with 16$^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse and the PPD values reach up to 50% in the 6th floor connection passage. In the case with fans, however, the vertical temperature difference were reduced to 9$^{\circ}C$ and the PPD values were lower below 20%. Consequently, the ventilating fans adopted on this study are effectively used for improving the thermal comfort in large space structure with thermal stratification.

Thermal Comfort Condition of Temperature and Humidity in Loess Interior Space

  • Kong, Sung-Hoon
    • 대한의생명과학회지
    • /
    • 제10권2호
    • /
    • pp.129-135
    • /
    • 2004
  • The study was carried out through measuring the temperature and humidity of the indoor/outdoor space and the distribution of interior thermal condition, and investigating the effect of loess materials on human body. The purpose of this study is to analyze the change of dry bulb temperature and relative humidity and correlation of thermal reaction of human body with ASHRAE (American Society of Heating, Refrigerating and Air-conditioning) comfort chart in the loess interior space. In the view point of biomedical sciences, loess interior space provides optimum thermal conditions for human thermal sensation.

  • PDF

베네시안 블라인드가 적용된 오피스 건물의 외피 투과체 계획을 위한 열·빛 환경 평가에 대한 연구 (Evaluation of Thermal and Visual Environment for the Glazing and Shading Device in an Office Building with Installed of Venetian Blind)

  • 김철호;김강수
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.101-109
    • /
    • 2015
  • Purpose: Glazing and shading devices influence a lot on the thermal and visual environment in office buildings. Solar heat and daylight are contrary concept, therefore proper arrangement of thermal and optical performance is needed when designing a glazing and shading devices. The purpose of this study is to examine the conditions of the glazing and shading devices available for promoting the reduction of cooling loads + lighting loads and the improvement in thermal comfort and visual comfort for the summer season in an office building installed with venetian blind. Method: This study established 12 simulation cases which have different glazings and the positions of venetian blind for evaluating different thermal and optical performance. And by using EnergyPlus v8.1 and Window v7.2 program, we quantitatively analyzed cooling loads + lighting loads, thermal comfort and visual comfort in an office building installed with the glazing and shading devices. Result: Consequently, Case 9(Double Low-E+Exterior Blind) is the best arrangement of solar heat gain and daylight influx, thereby becomes the most excellent case of reducing cooling+lighting loads(46.8%) and simultaneously becomes the enhancement case in thermal comfort. Also, DGI(Daylight glare index) under clear sky conditions in summer was evaluated to be 19.6, and thereby satisfied the recommendation level of allowing visual comfort.

새 국립중앙박물관 로튠다에서의 열환경 분석 (Analysis on Thermal Environment in the Rotunda of New National Museum of Korea)

  • 이승철;조영진;김두성;이재헌;김홍범
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.32-39
    • /
    • 2003
  • Thermal comfort in the Rotunda which is high wide visiting space of the new national museum of Korea has been numerically investigated in this paper. To evaluate thor-mal comfort of the Rotunda, well-known indices, PMV and PPD were introduced. The results of present investigation show that thermal comfort is satisfied at the breathing zone of the visiting space. However a thermal stratification with $9^{\circ}C$ of temperature difference occurs along the height of the Rotunda which makes the thermal environment worse. For example, the PPD value reaches up to 50% in the 6th floor connection passage. Consequently, additional HVAC design factors should be considered in order to reduce the large thermal stratification.

태양일사가 실내공간의 열적 쾌적성과 환기성능에 미치는 영향에 관한 연구 (The study on the effect of the solar radiation on thermal comfort and ventilation performance in room space)

  • 연성현;이효준;리광훈
    • 한국가시화정보학회지
    • /
    • 제14권1호
    • /
    • pp.19-26
    • /
    • 2016
  • Modern people spend much time at indoor space. So, People want to make better indoor air condition. But the facade of building is made of glass to be seen urbanely, the effect of solar radiation makes indoor environment worse. This study designs an open space affected by solar radiation with 4-way cassette air-conditioner. Using numerical simulation, this paper investigates thermal comfort and ventilation performance with discharge angles $30^{\circ}$ and $45^{\circ}$. To study thermal comfort, this paper studies distribution of velocity, temperature and effective draft temperature. Also, this paper introduces concept of air age to study ventilation performance. The flow influenced by solar radiation determines thermal comfort and ventilation performance in room space. This study shows that discharge angle of 45 degree has better thermal comfort and ventilation performance than that of 30 degree.

자연환기가 가능한 서울시 공동주택의 하절기 실내 온열 쾌적성 평가 (Evaluation of the Indoor Thermal Comfort in Naturally Ventilated Apartment During Summer)

  • 이승재;정창헌;황석호;김태연;이승복
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.59-66
    • /
    • 2010
  • Natural ventilation is major strategy of 'sustainable building'. It aims to supply fresh air to the indoor, and to remove heat from the indoor during summer. In the latter point of view, natural ventilation can be grouped into two main strategies, daytime ventilation and night cooing. If we take advantage of these two natural ventilation strategies, indoor thermal comfort can be significantly improved. This study focused on grasping the current situation and problem of indoor thermal comfort of the naturally ventilated residential buildings to seek for direction of later studies. Additionally, thermal comfort of residence where the interior blind and exterior insulation were applied was analyzed. It was analyzed that the percentage of the time which satisfy the indoor acceptable operative temperature during summer was 90 ~ 95% and the heat control performance of natural ventilation has a limitation. When the interior blind and exterior insulation were applied, indoor thermal comfort was significantly improved. However, it still need more improvement.

주거 공간에서의 룸 에어컨디셔너 실내기 유형에 따른 온열쾌적성 및 에너지성능 평가 (Evaluation of Thermal Comfort and Energy Efficiency According to Indoor-Unit Types of Room Air-Conditioner in Housing Space)

  • 석호태;김동우;양정훈
    • 한국주거학회논문집
    • /
    • 제20권4호
    • /
    • pp.19-29
    • /
    • 2009
  • The purpose of this study is to evaluate the air diffusion performance of a range of indoor units for room airconditioners; the wall-mounted type, floor-standing type, and ceiling-mounted type. These types of units, which have been widely used in housing spaces, will be studied with respect to thermal comfort and the energy performance using CFD analysis. In this study, current air conditioning status and related problems in housing spaces are examined, and a CFD analysis is performed in order to compare and analyze the thermal comfort and energy efficiency across each type of indoor-unit using the PMV, ADPI, EUC and FCEI indexes. The analysis results collectively considering thermal comfort and energy performance indicated that the ceiling-mounted type 4-way indoor unit showed the best diffusion performance in terms of thermal comfort, and had the second best diffusion performance in terms of energy performance after the wall-mounted type under certain conditions.

실내 온열쾌적성 평가를 위한 인체 모델링 및 격자특성에 대한 수치해석적 연구 (Numerical Study on Human Model's Shape and Grid Dependency for Indoor Thermal Comfort Evaluation)

  • 박재홍;서진원;최윤호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.210-217
    • /
    • 2011
  • Recently, research on evaluating thermal comfort by using CFD has been vigorously active. This research evaluates not only distribution of temperature and air flow analysing but also thermal comfort in indoor space by applying human model. But research of human model's shape, Grid characteristic and turbulence model has not yet been studied. In this paper, human model's shape, physical characteristic of variable Grid, and change of turbulence model has been studies by CFD. In this study. FLUENT is used for analysis and PMV(predicted Mean Vote), PPD(Predicted Percentage Dissatisfied) and EHT(Equivalent Homogeneous Temperature} are used for evaluation and comparison of thermal comfort. As a result, it shows that shape of CSP and lattice features does not affect on global flow field or evaluation on PMV, PPD. However, it demonstrates more precise result from evaluation of thermal comfort by equivalent temperature when it used detailed human model considering prism grid.

  • PDF

A Method to Protect Mine Workers in Hot and Humid Environments

  • Sunkpal, Maurice;Roghanchi, Pedram;Kocsis, Karoly C.
    • Safety and Health at Work
    • /
    • 제9권2호
    • /
    • pp.149-158
    • /
    • 2018
  • Background: Work comfort studies have been extensively conducted, especially in the underground and meteorological fields resulting in an avalanche of recommendations for their evaluation. Nevertheless, no known or universally accepted model for comprehensively assessing the thermal work condition of the underground mine environment is currently available. Current literature presents several methods and techniques, but none of these can expansively assess the underground mine environment since most methods consider only one or a few defined factors and neglect others. Some are specifically formulated for the built and meteorological climates, thus making them unsuitable to accurately assess the climatic conditions in underground development and production workings. Methods: This paper presents a series of sensitivity analyses to assess the impact of environmental parameters and metabolic rate on the thermal comfort for underground mining applications. An approach was developed in the form of a "comfort model" which applied comfort parameters to extensively assess the climatic conditions in the deep, hot, and humid underground mines. Results: Simulation analysis predicted comfort limits in the form of required sweat rate and maximum skin wettedness. Tolerable worker exposure times to minimize thermal strain due to dehydration are predicted. Conclusion: The analysis determined the optimal air velocity for thermal comfort to be 1.5 m/s. The results also identified humidity to contribute more to deviations from thermal comfort than other comfort parameters. It is expected that this new approach will significantly help in managing heat stress issues in underground mines and thus improve productivity, safety, and health.

HVAC 관련 매개변수 및 탑승조건에 따른 자동차 실내의 온열쾌적성 평가모델에 관한 수치해석적 연구 (A Numerical Study of Automotive Indoor Thermal Comfort Model According to Boarding Conditions and Parameters Related to HVAC)

  • 윤성현;박준용;손덕영;최윤호;박경석
    • 대한기계학회논문집A
    • /
    • 제38권9호
    • /
    • pp.979-988
    • /
    • 2014
  • 자동차를 이용하는 시간이 늘어남에 따라 자동차 실내의 온열쾌적성에 대한 관심이 급증하고 있다. 그러나 아직까진 실제 자동차 중에서 공조시스템의 냉방성능은 자동차 제조사별로 온열쾌적성 지표를 통해 평가되지 않고, 실내의 공기 속도와 온도 등 열환경 기준에 의해 평가되고 있다. 또한 차 실내의 온열쾌적성을 수치해석으로 평가하는 경우 타당한 결과를 도출할 수 있는 수치기법에 대한 기준이 확립되지 않은 상황이다. 본 연구에서는 외부 열원을 모사하기 위하여 태양광선 추적모델을 사용하고, 공조시스템 작동 후 20 분까지 다양한 매개변수(공조시스템의 작동모드와 작동풍량, 인체모델 탑승조건)에 대한 자동차 실내의 온열쾌적성 평가를 수행하였다. 이를 통해 자동차 실내의 온열쾌적성 지표를 예측할 수 있는 평가모델을 도출하였다.