• Title/Summary/Keyword: Thermal bridge

검색결과 294건 처리시간 0.029초

사무소 건축물의 단열상황에 관한 조사연구 (Survey Research on Thermal Situation of Office Buildings)

  • 정의인;김봉주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권3호
    • /
    • pp.145-152
    • /
    • 2013
  • 본 논문은 1990년대~2011년 시공 중이었던 건축물의 커튼월의 단열성을 평가하기 위하여 내외 표면 온도를 측정하여 부위별 온도 차이를 분석하였다. 유리면이나 단열층이 있는 표면보다 커튼월의 프레임 (멀리온 및 트랜섬)의 온도는 동절기 외부 평면의 경우 $6^{\circ}C{\sim}10^{\circ}C$ 정도 높게 나타났다. 또한, 같은 프레임에서도 앵커유닛이 있는 부위가 다른 프레임보다 $2^{\circ}C{\sim}3^{\circ}C$ 더 높게 나타나 보다 큰 열 손실이 일어나고 있는 것으로 나타났다.

온도 구배에 대한 P.C. 상자형 교량의 거동연구 (A Study on the Behavior of P.C. Box Girder Bridge for Temperature Gradients)

  • 손기훈;이성우
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.159-166
    • /
    • 1998
  • To study temperature effect of P.C. box girder bridge, field measurement was performed for six months, along with thermal analysis for the newly constructed viaduct of Gangbyun Highway in Seoul. Thermocouples were installed inside and surface of the flange and web of the box and temperature of box section md ambient temperature was measured. Measured environmental data are incorporated in finite element thermal analysis and computed temperature of the section was compared with measured one. Temperature gradient from thermal analysis was compared with Korean Highway Specification(1996)and the New Zealand Ministry of Works and Development code(1976). Thermal stress distribution across the box section was also compared.

  • PDF

교량 단면 내 온도분포에 따른 자체평형 열응력 해석 (Temperature Distribution and It's Contribution to Self-equilibrium Thermal Stress in Bridge)

  • 곽효경;권세형;하상희
    • 한국전산구조공학회논문집
    • /
    • 제24권5호
    • /
    • pp.531-542
    • /
    • 2011
  • 본 논문에서는 3차원 유한요소법과 수치시간적분을 사용하여 교량 내 단면의 시간에 따른 온도분포를 결정하였다. 초기재령 구조물의 거동을 효과적으로 모사하기 위해 시간에 따라 변하는 재료특성과 온도분포에 따른 열응력을 고려하였다. 온도분포는 비선형이며 열전도율, 비열, 콘크리트의 수화열, 대류계수 등의 재료 상수들과 태양열에 영향을 받으므로 주요한 영향인자인 시공시의 계절, 풍속, 교량 상판포장에 대한 영향을 고려하였다. 본 논문의 해석결과와 이전의 다른 해석연구와 비교를 통해 제안된 수치모델의 타당성을 검증하였다. 네 개의 다른 교량 단면의 연구를 토대로 더 타당한 설계결과를 얻기 위해서는 콘크리트 교량에서의 크리프 변형이 고려되어야 된다는 점과 도로교설계기준에서 제시한 온도분포는 개선될 필요가 있다는 것을 알 수 있었다.

신조 8,500GT 화학물 운반선의 여름철 선실 내 온열환경 실측평가 (A Measurement and Evaluation of the Indoor Thermal Conditions in Summer of a Newly-Launched 8,500GT Chemical Carrier)

  • 황광일;도근영;조효제;우상우;신동걸;임성택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.717-723
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions of a 8,500GT class chemical carrier which was launched on July 2007. The measurement was operated from 4th June to 4th June 2007, just before handing over to Owner. Followings are the results of this study. (1)The temperature variations of supply air were related to the outdoor temperature variations, but the humidity was stable at $65{\sim}80%$. (2)The temperature variations at the representative position of bridge, restaurant, crew's cabin showed gentle slopes. but that of conference room was very steepy. The humidities of bridge and restaurant were unstable because of outdoor-contact and cooking, respectively. (4)The temperature and humidity of ECR(Engine Control Room) which was designed to supply heating and cooling by PAC(Package Air Conditioner) were directly affected by the operating conditions of PAC. (5)The measured supply air volume from dampers of bridge, crew's cabin and conference room were satisfied with the design supply air volume. (5)For the improvement of the indoor thermal conditions, the temperature of crew's cabin and restaurant and the humidity of conference room, and the temperature and humidity of bridge should be controlled, respectively.

화재에 노출된 교량하부 강합성 구조물에 대한 열-구조 연성 병렬화재해석 (Thermal-Structure Interaction Parallel Fire Analysis for Steel-Concrete Composite Structures under Bridge Exposed to Fire Loading)

  • 윤성환;길흥배;이일근;김우석;박대효
    • 한국전산구조공학회논문집
    • /
    • 제26권4호
    • /
    • pp.283-292
    • /
    • 2013
  • 본 논문은 교량 하부에서 발생된 화재에 대한 강-콘크리트 합성구조의 전반적 국부적 손상평가를 위한 수치해석적 연구이다. 수치해석의 정확성 및 효율성을 높이기 위해 구성재료의 과도 비선형 열적 열역학적 특성이 고려된 열-구조 연성병렬 화재해석 기법이 제안되고, ANSYS solver와 연결되어 해석이 수행되며, 표준화재시험과 비교 검증된다. 검증된 해석기법을 통해 국내에서 발생된 부천고가교 합성구조에 대한 화재손상해석이 수행된다. 해석결과 강박스 거더의 하부 플랜지 및 복부의 경우 임계온도를 초과하였고 구조적 처짐과 변형 형상이 화재사고 결과와 비교적 잘 일치하였다.

인천대교 파일캡 구조물의 수화열 해석 및 계측 (Analysis and Measurements of Hydration Heat of Pile Cap in Incheon Bridge)

  • 박경래;윤만근;신현양;김영선;이광명
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.421-424
    • /
    • 2006
  • In massive hardening concrete structures, early age thermal cracking due to the heat of hydration may occur. There are many massive structures in Incheon bridge project and they have to be carefully treated to prevent thermal cracking. In this paper, an example of analyzed and measured results of hydration heat of pile caps in the Incheon bridge project was represented. Finite element simulations were carried out before casting and curing method was determined using the analyzed result. Sensors were installed before casting and temperature and strain of concrete was measured during curing. Gathered data were compared with the analyzed data and selected control method to prevent cracking was verified. Analyzed result gave good agreement and very few cracking could be found.

  • PDF

Temperature distribution behaviors of GFRP honeycomb hollow section sandwich panels

  • Kong, B.;Cai, C.S.;Pan, F.
    • Structural Engineering and Mechanics
    • /
    • 제47권5호
    • /
    • pp.623-641
    • /
    • 2013
  • The fiber-reinforced polymer (FRP) composite panel, with the benefits of light weight, high strength, good corrosion resistance, and long-term durability, has been considered as one of the prosperous alternatives for structural retrofits and replacements. Although with these advantages, a further application of FRPs in bridge engineering may be restricted, and that is partly due to some unsatisfied thermal performance observed in recent studies. In this regard, Kansas Department of Transportation (DOT) conducted a field monitoring program on a bridge with glass FRP (GFRP) honeycomb hollow section sandwich panels. The temperatures of the panel surfaces and ambient air were measured from December 2002 to July 2004. In this paper, the temperature distributing behaviors of the panels are firstly demonstrated and discussed based on the field measurements. Then, a numerical modeling procedure of temperature fields is developed and verified. This model is capable of predicting the temperature distributions with the local environmental conditions and material's thermal properties. Finally, a parametric study is employed to examine the sensitivities of several temperature influencing factors, including the hollow section configurations, environmental conditions, and material properties.

인덕션 쿡탑 기구물 형상변경이 Heatsink 및 Coil 냉각성능에 미치는 영향에 대한 연구 (Study on the Cooling Performance of Heatsink for Induction Cooktop using Computational Fluid Dynamics)

  • 박동호;권명근;이동범;서응렬;박용종
    • 한국유체기계학회 논문집
    • /
    • 제18권3호
    • /
    • pp.33-37
    • /
    • 2015
  • A numerical study on the IPM/Bridge Diode cooling and coil cooling has been performed. Results are presented as plots of thermal resistance, temperature drop and RPM-ratio. CFD analysis for conventional cooling system has been performed as a reference case. As the RPM-Ratio was increased, heatsink thermal resistance and coil temperature were decreased. IPM/Bridge Diode thermal resistance and temperature of the coil is tended to be trade-off. The temperature of coil closest to the AC-motor fan showed the most significant change in accordance with duct design. The temperature of coil located at the top of DC-motor fan showed the most significant variation as the cooling air passes the heatsink fin area.

목조건축물 구조부재의 열전도율에 따른 건물외피의 단열 성능 (Thermal Performance of Wooden Building Envelope by Thermal Conductivity of Structural Members)

  • 김석환;유슬기;서정기;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권6호
    • /
    • pp.515-527
    • /
    • 2013
  • 국내에서 주로 사용되고 있는 건물에너지 성능평가 시뮬레이션 마다 상이한 재료의 열전도율로 평가 되고 있음이 파악되었다. 시뮬레이션을 통한 정확한 건물에너지부하를 평가하기 위하여, 각 시뮬레이션에서 목조건축물의 스터드로 사용되고 있는 목재의 열전도율을 확인하고, 이에 따른 벽체의 열관류율과 부재 접합부위에서의 선형열교 차이를 연구하였다. 각 시뮬레이션은 동일 수종에 대해 상이한 열전도율을 채택 후, 각 시뮬레이션에서 추출한 열전도율 간의 차이가 가장 상이한 소나무의 열전도율을 스터드에 적용하였다. 시뮬레이션 간 지붕, 벽체, 지면 슬래브의 열관류율 중 최대오차는 $0.023W/m^2{\cdot}K$이었으며, 지붕의 서까래 접합부, 지붕-벽체 접합부, 지면슬래브-벽체 접합부 중 최대 선형열교 오차는 $0.025W/m{\cdot}K$이었다. 또한, HEAT2 정상상태전열해석 프로그램을 활용하여 선형열교 및 벽체의 온도변화에 대한 전열해석 이미지를 분석하였다. 구조체에 온도 분포를 선으로 표시하여 단열이 부족한 곳에서는 온도선이 급격하게 변하는 것이 확인되었고, 온도선이 급격하게 변하는 부위에서는 다른 곳보다 온도가 낮으며, 다른 구조체 부분보다 더 많은 열류가 손실됨이 확인되었다.