• 제목/요약/키워드: Thermal and electric energy

검색결과 547건 처리시간 0.029초

Experimental Study on Combined Ocean Thermal Energy Conversion with Waste Heat of Power Plant

  • Jung, Hoon;Jo, Jongyoung;Chang, Junsung;Lee, Sanghyup
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.215-222
    • /
    • 2019
  • This work is experimental study of 10 kW specialized Combined Ocean Thermal Energy Conversion. We propose a C-OTEC technology that directly uses exhaust thermal energy from power station condensers to heat the working fluid (R134a), and tests the feasibility of such power station by designing, manufacturing, installing, and operating a 10 kW-pilot facility. Power generation status was monitored by using exhaust thermal energy from an existing power plant located on the east coast of the Korean peninsula, heat exchange with 300 kW of heat capacity, and a turbine, which can exceed enthalpy efficiency of 45%. Output of 8.5 kW at efficiency of 3.5% was monitored when the condenser temperature and seawater temperature are $29^{\circ}C$ and $7.5^{\circ}C$, respectively. The evaluation of the impact of large-capacity C-OTEC technology on power station confirmed the increased value of the technology on existing power generating equipment by improving output value and reducing hot waste water. Through the research result, the technical possibility of C-OTEC has been confirmed, and it is being conducted at 200 kW-class to gain economic feasibility. Based on the results, authors present an empirical study result on the 200 kW C-OTEC design and review the impact on power plant.

스크류 캡슐형 밀폐식 빙축열시스템의 성능시험에 관한 연구 (Study on the Performance Testing of the Closed Ice Thermal Energy Storage System using Screw Capsules)

  • 김경환
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.39-45
    • /
    • 2006
  • The decrease in the summer peak electric load in our country is very important. The government has arranged and implemented a lot of support policies and statutes to decrease the peak electric load. And the ice thermal energy storage system is known as one of the alternatives. The purpose of this paper is to evaluate the efficiency and thermal characteristics of the closed ice thermal energy storage system using screw capsules. The measured thermal energy storage density is about 18.4 USRT-h/m3 (=232.9 MJ/m3), which is higher than 13.0 USRT-h/m3 (=164.6 MJ/m3), a low criterion of normal performance. And The efficiency of the discharging process and the total energy utilization is 96.2% and 2028.4 kcal/kWh respectively.

여름철 전기요금이 거주자의 냉방기 조작과 온열감에 미치는 효과 (Effect of Electric Charge on the Operating Behavior of Air-conditioner and Thermal Comfort in Summer Season)

  • 권서현;배누리;전정윤
    • 설비공학논문집
    • /
    • 제19권10호
    • /
    • pp.703-709
    • /
    • 2007
  • Much energy is used in occupying stage of the Building Life Cycle. Electric charge is one of the various factors that influence on energy use of residents. This study focused on electric charge and searched that whether electric charge affects residents' behavior of operating air conditioner and their controlled indoor climate. We surveyed three groups for field study ; A group is residents who live in a studio apartment, B group is residents who live in a university dormitory and C group is residents who live in a apartment with their family. The A and C groups are charged for electric as energy consumption they used. And the B group is students who live in a university dormitory and they are not charged for their energy consumption. We measured the time to use the air conditioner for cooling, on/off temperature of air conditioner, and room air temperature for these three groups. The result shows that consideration for electric charge affects to the residents' behavior of operating air conditioner and their acceptable thermal range.

습식온돌시스템과 전기온돌시스템의 열성능 평가 (Thermal Performance Assessment of Wet Ondol and Electric Ondol System)

  • 한병조;구경완
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.214-220
    • /
    • 2011
  • This paper studies about the assessment of thermal performance between wet ondol system and electric ondol system. Electrical ondol systems shows faster warm-up time, higher floor surface temperature distribution and lower power consumption than wet ondol system. However, if we provide heat regularly wet ondol system which has more heat capacity shows greater thermal storage than electric ondol system. Therefore, we could conclude that wet ondol system which keeps temperature regularly by the thermal storage show better energy-efficiency in case of using the central heating and district heating system. However, Electrical ondol system shows better efficiency in case of using the space during short time or individual heating systems which needs to heat quickly. The Experiment says that electric ondol system has more benefits on timing to reach the set temperature and energy-efficiency than wet ondol system.

증기발생기 열성능에 미치는 분산제 첨가효과 (Dispersant Effect on Thermal Performance of SG)

  • 이재근;문전수;윤석원;맹완영
    • 한국수소및신에너지학회논문집
    • /
    • 제22권4호
    • /
    • pp.546-551
    • /
    • 2011
  • The corrosion on steam generator tubes of the secondary side of pressurized water reactor inhibits heat transfer. One of the most efficient techniques improving the heat transfer performance of a nuclear electric generation is a corrosion control. The environmental parameters mostly affecting corrosion are materials and chemical additives. It seems that no further corrosion occurs in steels with Polyacrylic acid polymer dispersant treatment. Polyacrylic acid forms a protective coating with uniform thickness on metal surface. Polyacrylic treatment appears to be the most convenient way to enhance the thermal performance by the thermal conductivity improvement in steam generators.

서로다른 발전방식으로 운전되는 산업용 열병합발전시스템의 최적운전계획 수립 (Operation Scheduling of Industrial Cogeneration System with Each other Generation Mode)

  • 정지훈;이종범;오성근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 2000
  • This paper describes the strategy of a daily optimal operational scheduling on cogeneration systems with each other generation mode. The cogeneration systems consists of three generators. auxiiiary devices which are three auxiliary boilers, two waste boilers and three sludge incinerators. One unit that using the back pressure turbin generates the electrical and the thermal energy. The other two units that using the extraction condensing turbine generate the energy. Auxiliary devices operate to supplement the thermal energy to the thermal load with three units. The cogeneration system has a large capacity which is able to supply enough the thermal energy to the thermal load, however the electric power generated is insufficient to satisfy the electrical load. Therefore the insufficient electric energy is supplemented by buying electrical energy from the utility. Simulation was carried out using optimization toolbox. The result reveals that the proposed modeling and strategy can be effectively applied to cogeneration systems with each other generation mode.

  • PDF

표면 열전달 저항이 배제된 건물 벽체 열성능 현장 측정 기법 (In-situ Measurement Technique for Thermal Performance of Building Wall Excluding Surface Heat Transfer Resistance)

  • 김승철;김상봉;나환선
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권2호
    • /
    • pp.151-155
    • /
    • 2020
  • In this paper, a new experimental method to determine the thermal resistance of building wall was proposed by improving the heat flow method (HFM) based on the air-surface temperature ratio theory. This technique measures the thermal resistance of the wall excluding the inner and outer surface heat transfer resistance. Unlike conventional HFM, this value can be compared directly with the theoretical reference value. Its performance was verified using three mock-up structures with a theoretical thermal transmittance of 0.5, 3.3, and 0.18 W/㎡·K respectively. After measuring the variations in the temperature and heat transfer rate of the mock-ups for 383 hours, the thermal transmittances were determined to be 0.47, 3.10, and 0.18 W/㎡·K, which corresponded to errors of 5.2, 6.2 and 0.5%, respectively, compared to the theoretical values. It was concluded that this technique can directly compare the thermal resistance of the wall between the existent stage and initial stage after construction.

열전발전용 Peltier module의 특성 측정 (Characteristics of peltier module for thermoelectric generator)

  • 우병철;이희웅;이동윤;김봉서;슈마토크
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1552-1554
    • /
    • 1998
  • TEC(Thermoelectric conversion) is direct conversion method between thermal energy and electric energy. We studied on the mechanical, electrical and thermal properties of thermoelectric module, made experimental thermoelectric generator with BiTe material and manufactured module tester for electric-thermal energy conversion.

  • PDF

구조단열패널의 저에너지주택 적용을 위한 내화 및 단열성능 평가 (Fire Resistance Performance and Thermal Performance Evaluation of Structural Insulated Panels for Low-Energy Houses)

  • 이현주;나환선;이철희;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.36-46
    • /
    • 2012
  • Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard ($0.225W/m^2{\cdot}K$). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.

BiTe계 thermoelectric module을 이용한 발전기 제작과 특성 (Manufacturing of thermoelectric generator using BiTe module)

  • 우병철;김봉서;이희웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 C
    • /
    • pp.1446-1448
    • /
    • 1997
  • TEC(Thermoelectric conversion) is direct conversion method between thermal energy and electric energy. We studied on the mechanical, electrical and thermal properties of thermoelectric module and made experimental thermoelectric generator with BiTe material.

  • PDF