• Title/Summary/Keyword: Thermal analysis characteristics

Search Result 2,348, Processing Time 0.036 seconds

Changes of Electrical Conductivity and Temperature Caused by Cathode Erosion in a Free-Burning Argon Arc

  • Jeon, Hong-Pil;Lee, Jong-Cheol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.255.2-255.2
    • /
    • 2014
  • Electrode erosion is indispensable for atmospheric plasma systems, as well as for switching devices, due to the high heat flux transferred from arc plasmas to contacts, but experimental and theoretical works have not identified the characteristic phenomena because of the complex physical processes. Our investigation is concerned with argon free-burning arcs with anode erosion at atmospheric pressure by computational fluid dynamics (CFD) analysis. We are also interested in the energy flux and temperature transferring to the anode with a simplified unified model of arcs and their electrodes. In order to determine two thermodynamic quantities such as temperature and pressure and flow characteristics we have modified Navier-Stokes equations to take into account radiation transport, electrical power input and the electromagnetic driving forces with the relevant Maxwell equations. From the simplified self-consistent solution the energy flux to the anode can be derived.

  • PDF

Synthesis and Characteristics of New Poly(p-phenylenevinylene) with Bulky t-Octylphenoxy Group

  • Kim, Yun-Hi;Lee, Hyun-Ouk;Jung, Sung-Ouk;Kwon, Soon-Ki
    • Macromolecular Research
    • /
    • v.11 no.3
    • /
    • pp.194-197
    • /
    • 2003
  • A new 2,5-di(t-octylphenoxy) group substituted poly(p-phenylenevinylene) derivative was synthesized by Gilch polymerization. The obtained polymer was characterized by NMR, FT-IR, and chemical analysis and completely soluble in common organic solvents. The polymer showed good thermal stability with T$_{g}$ of 105$^{\circ}C$. The polymer dissolved in chloroform showed maximum emission at 514 nm with a shoulder peak at around 560 nm. The EL spectrum of the ITO/PEDOT/TOP-PPV/Al device was observed maximum emission at 545 nm with a shoulder peak at around 585 nm.m.

Hyperbranched poly(ether sulfone) with 1,3,5-s-Triazine Moiety

  • Youngkyu Chang;Kwon, Young-Chul;Park, Kyusoon;Im, Chulhee-K
    • Macromolecular Research
    • /
    • v.8 no.3
    • /
    • pp.142-146
    • /
    • 2000
  • Hyperbranched poly(ether sulfone) analogs with the 1,3,5-s-triazine moiety were prepared by the direct polymerization of AB$_2$type monomer, 2,4-bis(4-hydroxyphenyl)-6-(4-(4-(4-fluorobenzenesulfonyl)phenoxy)phenyl)-1,3,5-s-triazine (3). The selective reactivity of three chlorine atoms on cyanuric chloride toward nucleophiles provides an efficient route for the systematic synthesis of AB$_2$type triazine monomers and their hyperbranched polymers. The triazine rings influenced the structural and material characteristics of these hyperbranched polymers. The hyperbranched poly(ether sulfone) analog4 showed a glass transition at 295$^{\circ}C$. and was soluble in THF, 1,4-dioxane, and DMSO. An excellent thermal stability of polymer 4 was exhibited by a TGA analysis, which showed that 5% weight loss occurred at 480$^{\circ}C$.

  • PDF

Thermal Characteristics Analysis of Organic Electroluminescence Device using MEH-PPV (MEH-PPV를 이용한 유기전계발광소자의 열적 특성 분석)

  • Park, Jae-Young;Park, Seung-Wook;Shin, Moo-Whan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.112-116
    • /
    • 2001
  • Organic Electroluminescence device, which have the single-layer structure of ITO(indium-tin-oxide)/MEH-PPV (Poly[2-(2'-ethylhexyloxy )-5-methoxy-1,4-pheny lenevinylene])/Al(aluminium) and ITO/MEH-PPV/$Alq_3$(tris-8-hydroxyquinolinato aluminium)/Al were fabricated and electrical properties were investigated. Experimental results, in single-layer structure, shown that turn on voltage is about 12 V, and current density increases as a function of increasing temperature. It was explained by thermionic emission. In double-layer structure, thickness $200\AA$ of $Alq_3$ is shown electrical properties that turn on voltage is about 11 V, and current density decreases as a function of increasing temperature.ࠀȀ 耀Ѐ€

  • PDF

The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers (주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용)

  • Lee, B.S.;Song, I.K.;Lee, J.B.;Kim, D.M.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

Characteristics of Heteropoly Acid Catalyst for Emission Gas Control in Methanol Fueled Vehicles (메탄올 자동차 배기가스 정화용 헤테로폴리산 촉매의 특성)

  • 서성규;박남국;박훈수;김재승
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.1
    • /
    • pp.77-84
    • /
    • 1995
  • To prevent or reduce air pollutant from methanol fueled vehicles, methanol oxidation reaction was carried out using a heteropoly acid catalysts. Catalytic activities of catalysts have been experimented at atmospheric pressure in a fixed bed flow reactor. Catalysts were characterized by XRD, IR, thermal analysis, N $H_{3}$-TPD and GC pulse technique. Acidities of catalysts were highly affected by poly-atoms. Methanol conversion was much higher on catalyst with W than on catalyst with Mo as a poly-atoms. With the increase of copper content(X) in C $u_{x}$ $H_{{3-2x}}$PMo catalyst, acidity was decreased and oxidation ability was increased. Methanol conversion and product distribution were affected by the acidity and oxidation ability of catalyst. Especially, supported PdSiW(1wt%) catalyst has a very good methanol conversion and C $O_{2}$ selectivity as high as a commertial 3-way catalyst.t.

  • PDF

A Study on the Performance Improvement of the Micromachined Convective Accelerometer (열 대류 가속도계의 성능향상에 관한 연구)

  • Youn, Sung-Kie;Oh, Jun-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.5
    • /
    • pp.570-577
    • /
    • 2007
  • A micromachined convective accelerometer is a recently developed device. Typical micromachined accelerometers use a solid proof mass for measuring acceleration. But a micromachined convective accelerometer does not use a solid proof mass. A micromachined convective accelerometer is composed of a heating resistor and temperature sensors. This device measures acceleration by using convective heat transfer phenomenon. Therefore characteristics of a micromachined convective accelerometer are different as compared with typical micromachined accelerometer. In this research, we analyze the convective accelerometer by using transient convective heat transfer analysis. Based on the results of a convective accelerometer, we propose a new model which has improved performance.

Infrared Thermography Quantitative Diagnosis in Vibration Mode of Rotational Mechanics

  • Seo, Jin-Ju;Choi, Nam-Ryoung;Kim, Won-Tae;Hong, Dong-Pyo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.3
    • /
    • pp.291-295
    • /
    • 2012
  • In the industrial field, real-time monitoring system like a fault early detection is very important. For this, the infrared thermography technique as a new diagnosis method is proposed. This study is focused on the damage detection and temperature characteristic analysis of ball bearing using the non-destructive infrared thermography method. In this paper, thermal image and temperature data were measured by a Cedip Silver 450 M infrared camera. Based on the results, the temperature characteristics under the conditions of normal, loss lubrication, damage, dynamic loading, and damage under loading were analyzed. It was confirmed that the infrared technique is very useful for the detection of the bearing damage.

Experimental Analysis on the Thermal Plasma Characteristics in Non-Transferred Plasma Torches (비이송식 플라즈마 토치 구조에 따른 열플라즈마의 특성 시험 분석)

  • Jung, An-Mok;Lim, Jae-Koo;Jeon, Euy-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.442-445
    • /
    • 2008
  • 본 연구에서는 자장인가방식의 계단형 구조를 가지는 비이송식 플라즈마 토치를 설계 제작하여 토치의 전극 구조가 열플라즈마의 안정성에 미치는 영향을 진단하고 원통형 구조를 가지는 표준형 토치와 비교 분석하였다. 운전 변수인 전극 간격, 전류, 아크기체의 유량 변화에 따른 아크전압의 특성을 살펴보고, 설계 변수인 전극 구조에 따른 아크의 동적 특성 실험을 통해 열플라즈마의 특성에 미치는 영향을 실험적으로 규명 하였다.

  • PDF

A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX (CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.