• Title/Summary/Keyword: Thermal air treatment

Search Result 178, Processing Time 0.023 seconds

Studies on Raw-Water Source Heat Pump Equipped with Thermal Storage Tank in Water Treatment Facility (정수장 내 축열조 설치 원수열원 히트펌프의 성능분석)

  • Oh, Sun Hee;Yun, Rin;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.467-472
    • /
    • 2013
  • A raw-water source heat pump equipped with a thermal storage tank was dynamically simulated by TRNSYS, and the results were verified by using the data from a heat pump installed in the Seongnam water treatment facility. The average coefficient of performance (COP) of the raw-water source heat pump based on simulation was 4.97 and 3.17 in the cooling and heating season, respectively. When the volume of the thermal storage tank was changed from 5 to $20m^3$, the highest COP was found at a size of $10m^3$. Considering the regional locations of raw-water source heat pumps at Seoul, Incheon, Gangneung, and Gwangju, Seoul showed the lowest electric power consumption in the cooling season and the highest in the heating season. When a comparison of the performance between the present system and that of a water-air heat pump was conducted, the present system showed lower electric power consumption by 25% than that of a water-air heat pump.

Analysis of Organic Compounds in Ambient PM2.5 over Seoul using Thermal Desorption-comprehensive Two Dimensional Gas Chromatography-time of Flight Mass Spectrometry (TD-GCxGC-TOFMS) (Thermal Desorption-comprehensive Two Dimensional Gas Chromatography-time of Flight Mass Spectrometry (TD-GCxGC-TOFMS)을 이용한 서울 대기 중 PM2.5 유기성분 분석)

  • Lee, Ji-Yi;Lane, Douglas A.;Huh, Jong-Bae;Yi, Sung-Muk;Kim, Yong-Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.420-431
    • /
    • 2009
  • Characteristics and advantages of the thermal desorption-comprehensive two dimensional gas chromatography-time of flight mass spectrometry (TD-GCxGC-TOFMS) were discussed and the organic compound's analysis result was shown for the ambient $PM_{2.5}$ sample collected in Seoul, Korea. Over 10,000 individual organic compounds were separated from about $70{\mu}g$ of aerosols in a single procedure with no sample pre-treatment. Among them, around 300 compounds were identified and classified based on the mass fragmentation patterns and GCxGC retention times. Several aliphatic compounds groups such as alkanes, alkenes, cycloalkanes, alkanoic acids, and alkan-2-ones were identified as well as 72 PAH compounds including alkyl substituted compounds and 8 hopanes. In Seoul aerosol, numerous oxidized aromatic compounds including major components of secondary organic aerosols were observed. The inventory of organic compounds in $PM_{2.5}$ of Seoul, Korea suggested that organic aerosol were constituted by the compounds of primary source emission as well as the formation of secondary organic aerosols.

The Effect of Soil Warming on the Greenhouse Heating Load (지중가온이 온실의 난방부하에 미치는 영향)

  • Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.5
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

Low-Pressure Plasma Inactivation of Escherichia coli (감압 플라즈마를 이용한 Escherichia coli 살균)

  • Mok, Chulkyoon;Song, Dong-Myung
    • Food Engineering Progress
    • /
    • v.14 no.3
    • /
    • pp.202-207
    • /
    • 2010
  • Low-pressure plasmas (LPPs) were generated with different gases such as air, oxygen and nitrogen, and their inactivation effects against Escherichia coli were compared in order to evaluate the potential as a non-thermal microbial disinfection technology. Homogeneous plasmas were generated under low pressure below 1 Torr at gas flow rate of 350 mL/min regardless the types of gases. Temperature increases by LPPs were not detrimental showing less than ${10^{\circ}C}$ and ${25^{\circ}C}$ increases after 5 and 10 min treatments, respectively. The smallest temperature increase was observed with air LPP, and followed by oxygen and nitrogen LPPs. More than 5 log reduction in E. coli was achieved by 5 min LPP treatment but the destruction effect was retarded afterward. The LPP inactivation was represented by a iphasic first order reaction kinetics. The highest inactivation rate constant was achieved in air LPP and followed by oxygen and nitrogen LPPs. The small D-values of the LPP also supported its potentialities as a non-thermal food surface disinfection technology in addition to the substantial microbial reduction of more than 5 logs.

Development and Analysis of Physical Property of PP Shape Memory Fabrics for Emotional Garment (감성의류용 형상기억 PP직물 소재 개발과 물성분석)

  • Kim, Hyun-Ah;Kim, Seung-Jin
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.117-126
    • /
    • 2011
  • This study investigates the physical properties and manufacturing method of shape memory fabric for emotional garment made by polypropylene. For this purpose, polypropylene(PP) POY and SDY were texturized using low temperature and constant length heat treatment texturing technologies, respectively. The shape memory fabrics made using these texturized PP yarns were woven with two kinds of PET and PTT shape memory yarns on the air-jet loom and the various physical properties of four kinds of shape memory fabrics were measured and discussed. The tenacity and breaking strain of PP texturized yarns treated by low temperature and constant length heat treatment showed high weaving efficiency and the wet thermal shrinkage of PP textured yarns was shown less than 1.5%, dry thermal shrinkage was ranged between 3% and 5%, which means thermal stability compared to the PTT textured yarn with high thermal shrinkage, 5~8%. The shape memory characteristics of PP shape memory fabrics measured by Toray method showed five grade as same value as PTT shape memory fabric. The heat keeping property of the PP shape memory fabric showed 56% higher value than that of PTT shape memory fabric. The water repellency of PP shape memory fabric measured by spray method showed five grade as same value as PTT shape memory fabric treated with water repellent agent. Especially, shape memory properties of PP shape memory fabric measured by 3-D image and camera measurement methods showed similar characteristics to the PTT shape memory fabric.

  • PDF

Effect of plasma treatment using underwater non-thermal dielectric barrier discharge to remove antibiotics added to fish farm effluent (양식장 배출수에 첨가된 항생제 제거 위한 수중 비열 유전체장벽 방전 플라즈마 처리 효과)

  • Kyu Seok Cho;Han Seung Kang
    • Korean Journal of Environmental Biology
    • /
    • v.40 no.4
    • /
    • pp.641-650
    • /
    • 2022
  • The purpose of this study was to compare the efficiency of air and oxygen injected into the underwater non-thermal dielectric barrier discharge plasma (DBD plasma) device used to remove five types of antibiotics (tetracycline, doxycycline, oxytetracycline, clindamycin, and erythromycin) artificially contained in the fish farm discharge water. The voltage given to generate DBD plasma was 27.8 kV, and the measurement intervals were 0, 0.5, 1, 2, 4, 8, 16 and 32 minutes. Tetracycline antibiotics significantly decreased in 4 minutes when air was injected and were reduced in 30 seconds when oxygen was injected. After the introduction of air and oxygen at 32 minutes, 78.1% and 95.8% of tetracycline were removed, 77.1% and 96.3% of doxycycline were removed, and 77.1% and 95.5% of oxytetracycline were removed, respectively. In air and oxygen, 59.6% and 83.0% of clindamycin and 53.3% and 74.3% of erythromycin were removed, respectively. The two antibiotics showed lower removal efficiency than tetracyclines. In conclusion, fish farm discharge water contains five different types of antibiotics that can be reduced using underwater DBD plasma, and oxygen gas injection outperformed air in terms of removal efficiency.

Low Temperature Thermal Desorption (LTTD) Treatment of Contaminated Soil

  • Alistair Montgomery;Joo, Wan-Ho;Shin, Won-Sik
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.44-52
    • /
    • 2002
  • Low temperature thermal desorption (LTTD) has become one of the cornerstone technologies used for the treatment of contaminated soils and sediments in the United States. LTTD technology was first used in the mid-1980s for soil treatment on sites managed under the Comprehensive Environmental Respones, Compensation and Liability Act (CERCLA) or Superfund. Implementation was facilitated by CERCLA regulations that require only that spplicable regulations shall be met thus avoiding the need for protracted and expensive permit applications for thermal treatment equipment. The initial equipment designs used typically came from technology transfer sources. Asphalt manufacturing plants were converted to direct-fired LTTD systems, and conventional calciners were adapted for use as indirect-fired LTTD systems. Other innovative designs included hot sand recycle technology (initially developed for synfuels production from tar sand and oil shale), recycle sweep gas, travelling belts and batch-charged vacuum chambers, among others. These systems were used to treat soil contaminated with total petroleum hydrocarbons (TPH), polycyclic aromatic hydrocarbons (PAHs), pesticides, polychlorinated biphenyls (PCBs) and dioxin with varying degrees of success. Ultimately, performance and cost considerations established the suite of systems that are used for LTTD soil treatment applications today. This paper briefly reviews the develpoment of LTTD systems and summarizes the design, performance and cost characteristics of the equipment in use today. Designs reviewed include continuous feed direct-fired and indirect-fired equipment, batch feed systems and in-situ equipment. Performance is compared in terms of before-and-after contaminant levels in the soil and permissible emissions levels in the stack gas vented to the atmosphere. The review of air emissions standards includes a review of regulations in the U.S. and the European Union (EU). Key cost centers for the mobilization and operation of LTTD equipment are identified and compared for the different types of LTTD systems in use today. A work chart is provided for the selection of the optmum LTTD system for site-specific applications. LTTD technology continues to be a cornerstone technology for soil treatment in the U.S. and elsewhere. Examples of leading-edge LTTD technologies developed in the U.S. that are now being delivered locally in global projects are described.

  • PDF

Effects of Thermal Treatment and Freezing Storage Period on Physicochemical and Nutritional Characteristics of Shiitake Mushrooms (열처리 방법과 냉동 저장 기간에 따른 표고의 이화학적 및 영양학적 특성 변화)

  • Seo, Jae-Hee;Kim, Kwang-Il;Hwang, In-Guk;Yoo, Seon-Mi;Jo, Yeon-Ji;Min, Sang-Gi;Choi, Mi-Jung
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.3
    • /
    • pp.350-358
    • /
    • 2015
  • Freezing is one of the main processes to extend the shelf life of foods. Before freezing, a thermal treatment is normally required to control the food quality. In this study, shiitake mushrooms were heated with boiling water and with superheated steam. After the thermal treatments, the samples were continuously frozen by an individual quick freezing (IQF) process, and put them into air-containing or vacuum packaging. Samples were stored at -12, -18 and $-24^{\circ}C$ for 24 weeks, and their physicochemical properties were determined. The lightness of the samples treated with boiling water and superheated steam was decreased by 12 and 15%, respectively, than that of the control. The hardness of all the samples rapidly increased after heat treatment. The contents of organic acids in the superheated steam treated samples were higher than those in the boiling water treated samples. Therefore, superheated steam treatment of samples may be a candidate thermal treatment to preserve frozen shiitake mushrooms.

Adsorption and Desorption of Chemical Warfare Agent Simulants on Silica Surfaces with Hydrophobic Coating

  • Park, Eun Ji;Kim, Young Dok
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.7
    • /
    • pp.1967-1971
    • /
    • 2013
  • Aim of our study is finding adsorbents suitable for pre-concentration of chemical warfare agents (CWAs). We considered Tenax, bare silica and polydimethylsiloxane (PDMS)-coated silica as adsorbents for dimethyl methylphosphonate (DMMP) and dipropylene glycol methyl ether (DPGME). Tenax showed lower thermal stability, and therefore, desorption of CWA simulants and decomposition of Tenax took place simultaneously. Silica-based adsorbents showed higher thermal stabilities than Tenax. A drawback of silica was that adsorption of CWA simulant (DMMP) was significantly reduced by pre-treatment of the adsorbents with humid air. In the case of PDMS-coated silica, influence of humidity for CWA simulant adsorption was less pronounced due to the hydrophobic nature of PDMS-coating. We propose that PDMS-coated silica can be of potential importance as adsorbent of CWAs for their pre-concentration, which can facilitate detection of these CWAs.

A Thermal Decomposition Characteristics of Propellants for Safety Bag (에어백용 가스발생제의 열분해 특성)

  • 이내우
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.97-106
    • /
    • 1996
  • Some of accidents are based on unstable chemical substances. These chemicals are easily decomposed or Ignited by heats or mechanical shocks like sodium azide. Sodium azide is commonly used as propellant for inflating automotive safety bags and the other chemical manufacturing purposes. The investigation of thermal hazard potential of sodium azide is very important because unexpected traffic accident can be occureed. The experiments were carried out by DSC, TG an ARC in air, oxygen, argon and nitrogen atmosphere. The decomposition temperatures were about $410^{\circ}C$~$420^{\circ}C$ by DSC and $330^{\circ}C$~$370^{\circ}C$ by ARC, this is very significant result for treatment of chemical. The heats of decomposition were about 81 kcal/mol in ai. and 10 kcal/mol in other atmosphere.

  • PDF