• 제목/요약/키워드: Thermal Scale

검색결과 1,336건 처리시간 0.026초

Application of CUPID for subchannel-scale thermal-hydraulic analysis of pressurized water reactor core under single-phase conditions

  • Yoon, Seok Jong;Kim, Seul Been;Park, Goon Cherl;Yoon, Han Young;Cho, Hyoung Kyu
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.54-67
    • /
    • 2018
  • There have been recent efforts to establish methods for high-fidelity and multi-physics simulation with coupled thermal-hydraulic (T/H) and neutronics codes for the entire core of a light water reactor under accident conditions. Considering the computing power necessary for a pin-by-pin analysis of the entire core, subchannel-scale T/H analysis is considered appropriate to achieve acceptable accuracy in an optimal computational time. In the present study, the applicability of in-house code CUPID of the Korea Atomic Energy Research Institute was extended to the subchannel-scale T/H analysis. CUPID is a component-scale T/H analysis code, which uses three-dimensional two-fluid models with various closure models and incorporates a highly parallelized numerical solver. In this study, key models required for a subchannel-scale T/H analysis were implemented in CUPID. Afterward, the code was validated against four subchannel experiments under unheated and heated single-phase incompressible flow conditions. Thereafter, a subchannel-scale T/H analysis of the entire core for an Advanced Power Reactor 1400 reactor core was carried out. For the high-fidelity simulation, detailed geometrical features and individual rod power distributions were considered in this demonstration. In this study, CUPID shows its capability of reproducing key phenomena in a subchannel and dealing with the subchannel-scale whole core T/H analysis.

Micro-scale Thermal Sensor Manufacturing and Verification for Measurement of Temperature on Wafer Surface

  • Kim, JunYoung;Jang, KyungMin;Joo, KangWo;Kim, KwangSun
    • 반도체디스플레이기술학회지
    • /
    • 제12권4호
    • /
    • pp.39-44
    • /
    • 2013
  • In the semiconductor heat-treatment process, the temperature uniformity determines the film quality of a wafer. This film quality effects on the overall yield rate. The heat transfer of the wafer surface in the heat-treatment process equipment is occurred by convection and radiation complexly. Because of this, there is the nonlinearity between the wafer temperature and reactor. Therefore, the accurate prediction of temperature on the wafer surface is difficult without the direct measurement. The thermal camera and the T/C wafer are general ways to confirm the temperature uniformity on the heat-treatment process. As above ways have limit to measure the temperature in the precise domain under the micro-scale. In this study, we developed the thin film type temperature sensor using the MEMS technology to establish the system which can measure the temperature under the micro-scale. We combined the experiment and numerical analysis to verify and calibrate the system. Finally, we measured the temperature on the wafer surface on the semiconductor process using the developed system, and confirmed the temperature variation by comparison with the commercial T/C wafer.

분자동역학을 이용한 다공성 물질 건조공정 멀티스케일 시뮬레이션(2부: 미시 물성) (Multi-scale simulation of drying process for porous materials using molecular dynamics (part 2: material properties))

  • 백성민;금영탁
    • 한국결정성장학회지
    • /
    • 제15권4호
    • /
    • pp.162-167
    • /
    • 2005
  • 건조공정 중인 다공성 물질의 물성은 재료의 비균질성 즉 전위, 입자, 입계, 균열, 기공과 같은 미시적인 결함인자들의 영향을 받는다. 따라서 다공성 물질의 건조공정을 전산 시뮬레이션하기 위해서는 원자 스케일 해석을 통한 미시적 물성을 알아야 한다. 본 연구에서는 분자동역학 시뮬레이션을 이용하여 원자 모델을 구성하고 원자 상호간 거동을 예측하여 재료의 미시적 물성을 계산하였다. 이렇게 구한 탄성계수, 열팽창계수, 체적 열용량은 실험 및 이론에 기초한 결과들과 비교하여 검증하였다.

일개 한방병원에 내원한 갱년기 여성의 연령에 따른 적외선체열분포(DITI)와 Kupperman’s Index(KI), Menopause Rating Scale(MRS)간의 상관성 연구 (A Study on the Relationship between Digital Infrared Thermal Imaging (DITI), Kupperman’s Index (KI) and Menopause Rating Scale (MRS) of Postmenopausal Women)

  • 안뜰에봄;김동철
    • 대한한방부인과학회지
    • /
    • 제28권4호
    • /
    • pp.57-64
    • /
    • 2015
  • Objectives : To study correlation between Digital Infrared Thermal Imaging, Kupperman’s Index (KI) and Menopause Rating Scale (MRS) of Postmenopausal Women Methods : We analyzed 114 patients visiting Pohang Oriental Hospital from 1 st January 2014 to 30 th September 2015. The evaluating indexed of this trial were Age, DITI, KI, MRS. Temperature and different of temperature, such as In-dang (HN3), dan-Jung (CV17), gwan-won (CV4), hyup-back (LU4), no-gung (PC8), bock-to (ST31), and tae-chung (LR3). Results : Age was no correlation with DITI, KI, and MRS. There were positive correlation with KI and MRS significantly. DITI was not correlated with Age, KI and MRS, while ⊿T1 (LU4-PC8) was correlated with ⊿T2 (ST31-LR3) and ⊿T3 (CV17-CV4). Conclusions : There were non-significant correlation between DITI and Menopausal scale, but significant correlation in DITI themselves, Menopausal themselves. The More studies ar needed for the more accurate oriental medical diagnosis

RECENT IMPROVEMENTS IN THE CUPID CODE FOR A MULTI-DIMENSIONAL TWO-PHASE FLOW ANALYSIS OF NUCLEAR REACTOR COMPONENTS

  • Yoon, Han Young;Lee, Jae Ryong;Kim, Hyungrae;Park, Ik Kyu;Song, Chul-Hwa;Cho, Hyoung Kyu;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.655-666
    • /
    • 2014
  • The CUPID code has been developed at KAERI for a transient, three-dimensional analysis of a two-phase flow in light water nuclear reactor components. It can provide both a component-scale and a CFD-scale simulation by using a porous media or an open media model for a two-phase flow. In this paper, recent advances in the CUPID code are presented in three sections. First, the domain decomposition parallel method implemented in the CUPID code is described with the parallel efficiency test for multiple processors. Then, the coupling of CUPID-MARS via heat structure is introduced, where CUPID has been coupled with a system-scale thermal-hydraulics code, MARS, through the heat structure. The coupled code has been applied to a multi-scale thermal-hydraulic analysis of a pool mixing test. Finally, CUPID-SG is developed for analyzing two-phase flows in PWR steam generators. Physical models and validation results of CUPID-SG are discussed.

압박손상으로 발생한 비골신경마비 환자 치험 1례 (A Clinical study on Sitting Cross-Legged Patient Diagnosed as Peroneal Neuropathy)

  • 김정아;지민정;원제훈;안뜰에봄;김동철
    • 척추신경추나의학회지
    • /
    • 제9권1호
    • /
    • pp.77-87
    • /
    • 2014
  • Objectives: The Purpose of this study is to report the effects of Korean medical treatment on patient of peroneal neuropathy caused by sitting cross-legged. Methods: The patient diagnosed as peroneal neuropathy was treated by Acupuncture, Bee Venom therapy, Herbal medicine. To evaluate the effects of Korean treatment, we used Range of Motion(ROM) of Ankle, Visual Analog Scale(VAS), Numeric Rating Scale(NRS), Ankle-Hind-foot Scale(AHS), Digital Infrared Thermal Imaging(DITI). Results: After treatment, ROM of Ankle, VAS, NRS, AHS were improved. Temperature Difference(${\Delta}T$) was decreased on DITI. Conclusions: This study suggests that Korean medical treatment might be effective on sitting cross-legged patient diagnosed as Peroneal Neuropathy.

  • PDF

3중관용 스페이서를 적용한 대구경 지중열교환기의 성능측정에 관한 연구 (An Experimental Study on the Thermal Performance Measurement of Large Diameter Borehole Heat Exchanger(LD-BHE) for Tripe-U Pipes Spacer Apply)

  • 이상훈;박종우;임경빈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.581-586
    • /
    • 2009
  • Knowledge of ground thermal properties is most important for the proper design of large scale BHE(borehole heat exchanger) systems. The type, pipe size and thermal performance of the BHE is highly dependent on the ground source heatpump system-efficiency and instruction cost. Thermal response tests with mobile measurement devices were developed primarily for insitu determination of design data for large diameter BHE for triple-U spacer apply. The main purpose has been to determine insitu values of effective ground thermal conductivity and thermal resistance, including the effect of ground-water flow and natural convection in the boreholes. The test rig is set up on a some trailer, and contains a circulation pump, a inline heater, temperature sensors, flow meter, power analysis meter and a data logger for recording the temperature, fluid flow data. A constant heat power is injected into the borehole through the tripl-U pipes system of test rig and the resulting temperature change in the borehole is recorded. The recorded temperature data are analysed with a line-source model, which gives the effective insitu values of rock thermal conductivity and borehole thermal resistance of large diameter BHE for spacer apply.

  • PDF

수평배관에서의 열유동 성층화현상에 대한 실험적 연구 (Experimental Study on the Thermal Flow Stratification in a Horizontal Piping System)

  • 김병주;이찬우;장원표
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.2064-2070
    • /
    • 1995
  • Characteristics of thermal flow stratification were studied experimentally by using the small scale pressurizer-surge line model. Thermal flow stratifications in the horizontal section of surge line were analyzed by the relation between the maximum temperature difference at any cross section in surge line and the Froude number representing the boundary conditions, i.e., in/out surge flow velocity and temperature difference of system. Thermal flow stratifications in outsurge flow decreased inversely proportional to the Froude number and did not exist for Fr>1. In insurge flow thermal flow stratifications disappeared near Fr=1.5, but resulted in the higher temperature difference than the case of outsurge flow.

Stability characteristic of bi-directional FG nano cylindrical imperfect composite: Improving the performance of sports bikes using carbon nanotubes

  • Chaobing Yan;Tong Zhang;Ting Zheng;Tayebeh Mahmoudi
    • Steel and Composite Structures
    • /
    • 제50권4호
    • /
    • pp.459-474
    • /
    • 2024
  • Classical and first-order nonlocal beam theory are employed in this study to assess the thermal buckling performance of a small-scale conical, cylindrical beam. The beam is constructed from functionally graded (FG) porosity-dependent material and operates under the thermal conditions of the environment. Imperfections within the non-uniform beam vary along both the radius and length direction, with continuous changes in thickness throughout its length. The resulting structure is functionally graded in both radial and axial directions, forming a bi-directional configuration. Utilizing the energy method, governing equations are derived to analyze the thermal stability and buckling characteristics of a nanobeam across different beam theories. Subsequently, the extracted partial differential equations (PDE) are numerically solved using the generalized differential quadratic method (GDQM), providing a comprehensive exploration of the thermal behavior of the system. The detailed discussion of the produced results is based on various applied effective parameters, with a focus on the potential application of nanotubes in enhancing sports bikes performance.

한지창호의 실내 온.습도 조절효과에 관한 실험적 연구 (An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control)

  • 장길수;박사근;송민정;신훈
    • 한국주거학회논문집
    • /
    • 제17권2호
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.