• 제목/요약/키워드: Thermal Protection Material

검색결과 121건 처리시간 0.024초

25.8kV 고체절연스위치기어 개발 (Development of 25.8kV class solid insulated switchgear)

  • 이종혁;마지훈;유련;이재걸;원성연;이석원;김영근;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2008
  • In recent years, the companies of electric power equipment for MV and HV classes trend to develop the eco-friendly insulated(solid, eco-gas, air etc.) switchgear which replaces existent SF6 gas insulated switchgear due to environmental problems such as global warming and so on. This paper makes reference to the newly developed Solid Insulated Switchgear (SIS) which uses the eco-friendly material such as epoxy for insulation. The insulation of the solid insulated switchgear (SIS) is composed of an epoxy, vacuum and air. The solid insulated switchgear (SIS) is a slate of the art product. The advantages of SIS are advanced reliability, economical efficiency, safety, maintenance free, reduction of installation area and the protection of environment. The solid insulated switchgear (SIS) is FE Analyzed such as electromagnetic, mechanical, thermal and fluid in order to find the optimal design. Thens SIS has been verified by international standard test. (IEC 62271 - 100 and so on.) As a result of this, the solid insulated switchgear (SIS) has been estimated as an alternative for eco-friendly MV class switchgear.

  • PDF

우주용 일체형 경량 복합재료 전자장비 하우징 제작에 관한 연구 (A Study on Fabrication of Monolithic Lightweight Composite Electronics Housing for Space Application)

  • 장태성;서정기;이주훈
    • 한국항공우주학회지
    • /
    • 제41권12호
    • /
    • pp.975-986
    • /
    • 2013
  • 기존 위성 전자장비 하우징에 널리 사용되는 알루미늄 합금 소재를 경량 복합재료로 대체함으로써 위성 경량화를 크게 개선하고자, 경량 복합재료로 구성된 전자장비 하우징을 제작하고 성능 검증에 대하여 다루었다. 이를 위해 복합재료의 낮은 가공성을 극복하기 위하여 후처리를 최소화할 수 있는 복합재료 하우징 제작공정을 설계하고, 격자 구조로 강화된 일체형 하우징 본체를 동시경화 방법에 의해 제작하였다. 또한 제작된 전자장비 하우징의 내구성, 강성, 열전도도, 전기전도도, EMI차폐 및 방사차폐에 대한 성능 평가 결과를 분석하였다. 아울러 본 연구에서 제작한 복합재료 하우징은, 동일한 형상의 알루미늄 하우징 대비 상당한 질량절감을 가능하게 함을 제시하였다.

저열유속 조건의 복사열 노출에 따른 소방보호복의 열보호성능 측정에 관한 연구 (Study on the Thermal Protective Performance Measurements of Fire Fighter's Protective Clothing for Low Level Radiant Heat Exposures)

  • 이준경;방영준;방창훈;권정숙
    • 한국화재소방학회논문지
    • /
    • 제28권2호
    • /
    • pp.1-8
    • /
    • 2014
  • 보호복 섬유 및 재료의 개발을 통해 나아진 단열 성능을 제공함에도 불구하고 보호복의 화상 방지는 아직도 중요한 사항이다. 화염으로부터의 보호성능을 보장받기 위해서 보호복의 정확한 성능검증이 필요하며, 열보호 특성을 정확히 파악하기 위해 ISO 등은 시험방법을 표준화하여 제시하고 있다. 하지만 대부분의 경우, 높은 열유속 조건에 대해 보호복의 열보호 성능을 시험하는 것으로 되어 있어, 고열유속에 의한 시편의 파괴가 일어나기 쉽다. 그러므로 낮은 열유속 조건에서 보호복의 열보호 성능을 측정하는 방법이 필요하며, 본 연구에서는 낮은 열유속에 대한 열보호 성능을 측정할 수 있는 화상 및 통증유발시간에 기초한 개선된 RPP(복사열 보호 성능) 지수와 그의 측정방법을 제안하였다. 또한 제안된 열보호성능 측정 방법을 실험을 통해 확인하고, 보호복의 비정상열전달특성을 파악하였다. 또한 기존의 여러 가지 열보호성능지표들과 제안지표와의 관계를 제시하였다.

밸러스트 수 처리를 위한 Plasma Gun의 오존생성에 미치는 운전변수의 영향 (Effects of Operating Parameters on Ozone Production by Plasma Gun for Ballast Water Treatment)

  • 이현돈;김종오;정재우
    • 한국항해항만학회지
    • /
    • 제34권3호
    • /
    • pp.205-211
    • /
    • 2010
  • 밸러스트수 처리를 위한 Plasma Gun의 전기적 특성과 오존 생성에 미치는 주요 운전변수들의 영향에 관해 실험실 규모 연구를 수행하였다. 방전개시전압보다 높은 전압이 인가되면 방전이 시작되고 오존이 생성되었으며 전압이 증가함에 따라 기체로 전달되는 에너지 및 오존 농도가 거의 선형적으로 증가하였다. 오존 생성 측면에서 최적의 에너지 효율성을 얻을 수 있는 전극간 거리가 존재하였으며 실험된 장치에서는 1.95 mm의 전극간 거리에서 최적 효율이 얻어졌다. 전기에너지 특성에 미치는 내부전극 재질의 영향은 무시할만한 수준이었으나 내부전극의 전기전도도와 열전도도 차이가 오존 생성에 큰 영향을 미치는 것으로 나타났다. 일정한 Plasma Gun 구조에서 오존 생성은 기체로 전달되는 에너지밀도에 의해 중요한 영향을 받는 것으로 나타났으며 유입되는 기체의 산소함량이 증가할수록 오존 생성이 증가하는 것으로 나타났다.

사파이어 기판을 사용한 AlGaN/GaN 고 전자이동도 트랜지스터의 정전기 방전 효과 (Eletrostatic Discharge Effects on AlGaN/GaN High Electron Mobility Transistor on Sapphire Substrate)

  • 하민우;이승철;한민구;최영환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권3호
    • /
    • pp.109-113
    • /
    • 2005
  • It has been reported that the failure phenomenon and variation of electrical characteristic due to the effect of electrostatic discharge(ESD) in silicon devices. But we had fess reports about the phenomenon due to the ESD in the compound semiconductors. So there are a lot of difficulty to the phenomenon analysis and to select the protection method of main circuits or the devices. It has not been reported that the relation between the ESD stress and GaN devices, which is remarkable to apply the operation in high temperature and high voltage due to the superior material characteristic. We studied that the characteristic variation of the AlGaN/GaN HEMT current, the leakage current, the transconductance(gm) and the failure phenomenon of device due to the ESD stress. We have applied the ESD stress by transmission line pulse(TLP) method, which is widely used in ESD stress experiments, and observed the variation of the electrical characteristic before and after applying the ESD stress. The on-current trended to increase after applying the ESD stress. The leakage current and transconductance were changed slightly. The failure point of device was mainly located in middle and edge sides of the gate, was considered the increase of temperature due to a leakage current. The GaN devices have poor thermal characteristic due to usage of the sapphire substrate, so it have been shown to easily fail at low voltage compared to the conventional GaAs devices.

A Preliminary Design Concept of the HYPER System

  • Park, Won S.;Tae Y. Song;Lee, Byoung O.;Park, Chang K.
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.42-59
    • /
    • 2002
  • In order to transmute long-lived radioactive nuclides such as transuranics(TRU), Tc-99, and I- l29 in LWR spent fuel, a preliminary conceptual design study has been performed for the accelerator driven subcritical reactor system, called HYPER(Hybrid Power Extraction Reactor) The core has a hybrid neutron energy spectrum: fast and thermal neutrons for the transmutation of TRU and fission products, respectively. TRU is loaded into the HYPER core as a TRU-Zr metal form because a metal type fuel has very good compatibility with the pyre- chemical process which retains the self-protection of transuranics at all times. On the other hand, Tc-99 and I-129 are loaded as pure technetium metal and sodium iodide, respectively. Pb-Bi is chosen as a primary coolant because Pb-Bi can be a good spallation target and produce a very hard neutron energy spectrum. As a result, the HYPER system does not have any independent spallation target system. 9Cr-2WVTa is used as a window material because an advanced ferritic/martensitic steel is known to have a good performance under a highly corrosive and radiation environment. The support ratios of the HYPER system are about 4∼5 for TRU, Tc-99, and I-129. Therefore, a radiologically clean nuclear power, i.e. zero net production of TRU, Tc-99 and I-129 can be achieved by combining 4 ∼5 LWRs with one HYPER system. In addition, the HYPER system, having good proliferation resistance and high nuclear waste transmutation capability, is believed to provide a breakthrough to the spent fuel problems the nuclear industry is faced with.

Fabrication, characterization, simulation and experimental studies of the ordinary concrete reinforced with micro and nano lead oxide particles against gamma radiation

  • Mokhtari, K.;Kheradmand Saadi, M.;Ahmadpanahi, H.;Jahanfarnia, Gh.
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3051-3057
    • /
    • 2021
  • The concrete is considered as an important radiation shielding material employed widely in nuclear reactors, particle accelerators, laboratory hot cells and other different radiation sources. The present research is dedicated to the shielding properties study of the ordinary concrete reinforced with different weight fractions of lead oxide micro/nano particles. Lead oxide particles were fabricated by chemical synthesis method and their properties including the average size, morphological structure, functional groups and thermal properties were characterized by XRD, FESEM-EDS, FTIR and TGA analysis. The gamma ray mass attenuation coefficient of concrete composites has been calculated and measured by means of the Monte Carlo simulation and experimental methods. The simulation process was based on the use of MCNP Monte Carlo code where the mass attenuation coefficient (μ/ρ) has been calculated as a function of different particle sizes and filler weight fractions. The simulation results showed that the employment of the lead oxide filler particles enhances the mass attenuation coefficient of the ordinary concrete, drastically. On the other hand, there are approximately no differences between micro and nano sized particles. The mass attenuation coefficient was increased by increasing the weight fraction of nanoparticles. However, a semi-saturation effect was observed at concentrations more than 10 wt%. The experimental process was based on the fabrication of concrete slabs filled by different weight fractions of nano lead oxide particles. The mass attenuation coefficients of these slabs were determined at different gamma ray energies using 22Na, 137Cs and 60Co sources and NaI (Tl) scintillation detector. The experimental results showed that the HVL parameter of the ordinary concrete reinforced with 5 wt% of nano PbO particles was reduced by 64% at 511 keV and 48% at 1332 keV. Reasonable agreement was obtained between simulation and experimental results and showed that the employment of nano PbO particles is more efficient at low gamma energies up to 1Mev. The proposed concrete is less toxic and could be prepared in block form instead of toxic lead blocks.

Numerical and experimental analysis on the axial compression performance of T-shaped concrete-filled thin-walled steel

  • Xuetao Lyu;Weiwei Wang;Huan Li;Jiehong Li;Yang Yu
    • Steel and Composite Structures
    • /
    • 제50권4호
    • /
    • pp.383-401
    • /
    • 2024
  • The research comprehensively studies the axial compression performance of T-shaped concrete-filled thin-walled steel tubular (CTST) long columns after fire exposure. Initially, a series of tests investigate the effects of heating time, load eccentricity, and stiffeners on the column's performance. Furthermore, Finite Element (FE) analysis is employed to establish temperature and mechanical field models for the T-shaped CTST long column with stiffeners after fire exposure, using carefully determined key parameters such as thermal parameters, constitutive relations, and contact models. In addition, a parametric analysis based on the numerical models is conducted to explore the effects of heating time, section diameter, material strength, and steel ratio on the axial compressive bearing capacity, bending bearing capacity under normal temperature, as well as residual bearing capacity after fire exposure. The results reveal that the maximum lateral deformation occurs near the middle of the span, with bending increasing as heating time and eccentricity rise. Despite a decrease in axial compressive load and bending capacity after fire exposure, the columns still exhibit desirable bearing capacity and deformability. Moreover, the obtained FE results align closely with experimental findings, validating the reliability of the developed numerical models. Additionally, this study proposes a simplified design method to calculate these mechanical property parameters, satisfying the ISO-834 standard. The relative errors between the proposed simplified formulas and FE models remain within 10%, indicating their capability to provide a theoretical reference for practical engineering applications.

화재 온도를 받는 고인성.고내화성 시멘트 복합체의 거동 (Behavior of Fire Resistance Engineered Cementitious Composites(FR-ECC) under Fire Temperature)

  • 한병찬;권영진;김재환
    • 콘크리트학회논문집
    • /
    • 제19권2호
    • /
    • pp.189-197
    • /
    • 2007
  • 터널 라이닝은 대형 화재 등과 같은 고온에 노출될 경우, 폭렬이 발생하고 이로 인해 급격한 온도 전달 및 내력 저하로 구조체 붕괴의 원인이 될 수 있다는 것이 여러 사례를 통해 보고되고 있다. 본 연구는 터널라이닝의 내화뿜칠 재료로 매우 적합할 것으로 판단되는 고인성 고내화성 시멘트 복합체(FR-ECC)를 개발하고 이의 역학적 특성 및 내화 성능을 평가하고자 하였다. 이를 위하여 FR-ECC에 있어서의 배합 요인을 실험 변수로 내화 시험을 실시하였으며 비정상 온도 분포 해석 기법(nonlinear transient heat flow analysis)을 이용하여 이를 해석적으로 묘사 검증되었다. 또한, 실험 결과를 통해 검증된 해석 기법을 이용하여 터널라이닝에 대한 열전달 해석을 수행하여 FR-ECC를 내화 2차 라이닝재로 이용하는 경우의 거동 특성을 분석하였다. 실험 결과 내화 성능을 향상시키기 위한 FR-ECC의 최적 배합은 PVA 섬유 또는 PP 섬유 혼입률 $V_f=2.0%$, 다공성 세라믹재 혼입률 $V_C=3.6%$, 공기량 $V_A=15%$로 나타났으며, 검증된 비정상 온도 분포 해석 기법을 이용하여 기존 터널에 40mm FR-ECC를 추가 라이닝 한 경우에 대한 해석 결과, 콘크리트 및 철근의 온도 분포가 모두 $350^{\circ}C$ 이내에서 제어되어 터널 내 콘크리트 및 철근에 대한 화재 피해를 방지할 수 있을 것으로 판단되었다.

스마트 액추에이터를 위한 폴리이미드 및 액정 엘라스토머 이중층의 미세패터닝 (Micropatterning of Polyimide and Liquid Crystal Elastomer Bilayer for Smart Actuator)

  • 성예린;최현승;송원성;바네사;김유리;류연해;김영진;임재민;김대석;최현호
    • 접착 및 계면
    • /
    • 제25권1호
    • /
    • pp.169-274
    • /
    • 2024
  • 최근 외부 자극에 따라 팽창과 수축을 가역적으로 반복하며 형태가 변하는 소재가 주목받고 있다. 이러한 소재는 소프트 로봇, 센서, 인공근육 등 다양한 분야로의 응용가능성을 가지고 있다. 본 연구에서는 고온 물질에 감응하여 이를 보호하거나 감쌀 수 있는 새로운 소재를 제안하였다. 이를 위해, 네마틱-등방성 전이 성질을 지닌 액정 엘라스토머(liquid crystal elastomer, LCE)와 높은 기계적 강도와 고온 수치 안정성을 지닌 폴리이미드(polyimide, PI)를 이용하였다. 용액공정으로 합성된 도프 용액을 마이크로 프린팅 기법에 도입하여 mm 미만의 마이크론 선폭을 지닌 LCE/PI 이중층 구조 2차원 패턴을 개발하였다. 벌집구조로 패턴된 LCE/PI 이중층 메쉬는 PI의 기계적 강도와 LCE 고온 수축 거동의 장점을 동시에 가지고 있었고, LCE 선택적 프린팅을 통해 고온에서 원하는 방향으로의 변형을 유도할 수 있었다. 그 결과, 특정 고온 물질을 가역 반복적으로 감쌀 수 있는 기능을 구현하였다. 본 연구는 LCE 분자 변화에 따라 다양한 온도 구간에서 전기에너지 인가없이 기능을 구현할 수 있는 다양한 액추에이터 분야의 응용 가능성을 시사한다.