• Title/Summary/Keyword: Thermal Line Sensor

Search Result 47, Processing Time 0.033 seconds

A Study on the Performance Test and Manufacture of the Dielectric Sensor for the Cure Monitoring of the High Temperature Composites (고온 복합재료의 경화 모니터링을 위한 고온 유전센서의 제작 및 성능평가에 관한 연구)

  • 김일영;최진호;이대길
    • Composites Research
    • /
    • v.14 no.1
    • /
    • pp.30-38
    • /
    • 2001
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the on-line cure monitoring during the cure process of the composite materials has become an important research area for the better quality and productivity. In this paper, the dielectric circuit of the Wheatstone bridge type for measuring the dissipation factor during cure of thermsetting resin matrix composite materials was designed and manufactured. Also, the dielectric sensor for the cure monitoring of high temperature cure composites was developed and tested. The residual thermal stresses of the dielectric sensor during high temperature cure were analyzed by the finite element method and its dielectric characteristics at high temperature cure were analyzed by the finite element method and its dielectric characteristics at high temperature were evaluated. The on-line cure monitoring of the BMI(Bismaleimide) resin was performed using the developed Wheatstone bridge type circuit and the high-temperature dielectric sensor.

  • PDF

Stabilization and thermal conductivity measurement of MWCNT nanofluids by using the $3-{\omega}$ method (3-${\omega}$ 방법을 이용한 다중벽 탄소나노튜브 나노유체의 침전 안정성 및 열전도계수 측정에 관한 실험적 연구)

  • Oh, Dong-Wook;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2171-2176
    • /
    • 2007
  • The 3-omega (3-${\omega}$) method is utilized to measure the thermal conductivity of nanofluids. A metal line heater on a silicon nitride membrane bridge structure is microfabricated by a bulk silicon etching method. Localized measurement of the thermal conductivity within the nanofluids droplet is possible by the fabricated 3-${\omega}$ sensor. Time varying AC temperature amplitudes and thermal conductivities are measured to check the stability of the nanofluids containing multi-wall carbon nanotubes (MWCNTs). Stabilities of MWCNT nanofluids prepared with different chemical treatments are compared. Acid treated MWCNT showed best dispersion stability in water while MWCNTs dispersed in water with surfactants such as Gum Arabic and Sodium dodecyl benzene sulfate showed clear sign of gravity dependence.

  • PDF

GEOMETRY OF SATELLITE IMAGES - CALIBRATION AND MATHEMATICAL MODELS

  • JACOBSEN KARSTEN
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.182-185
    • /
    • 2005
  • Satellite cameras are calibrated before launch in detail and in general, but it cannot be guaranteed that the geometry is not changing during launch and caused by thermal influence of the sun in the orbit. Modem satellite imaging systems are based on CCD-line sensors. Because of the required high sampling rate the length of used CCD-lines is limited. For reaching a sufficient swath width, some CCD-lines are combined to a longer virtual CCD-line. The images generated by the individual CCD-lines do overlap slightly and so they can be shifted in x- and y-direction in relation to a chosen reference image just based on tie points. For the alignment and difference in scale, control points are required. The resulting virtual image has only negligible errors in areas with very large difference in height caused by the difference in the location of the projection centers. Color images can be related to the joint panchromatic scenes just based on tie points. Pan-sharpened images may show only small color shifts in very mountainous areas and for moving objects. The direct sensor orientation has to be calibrated based on control points. Discrepancies in horizontal shift can only be separated from attitude discrepancies with a good three-dimensional control point distribution. For such a calibration a program based on geometric reconstruction of the sensor orientation is required. The approximations by 3D-affine transformation or direct linear transformation (DL n cannot be used. These methods do have also disadvantages for standard sensor orientation. The image orientation by geometric reconstruction can be improved by self calibration with additional parameters for the analysis and compensation of remaining systematic effects for example caused by a not linear CCD-line. The determined sensor geometry can be used for the generation? of rational polynomial coefficients, describing the sensor geometry by relations of polynomials of the ground coordinates X, Y and Z.

  • PDF

A Study on the Laser Welding of Cladding Tube with Temp. Sensor for Fuel Irradiation Test (핵연료 조사시험용 온도센서 피복재의 레이저용접 연구)

  • Kim, Su-Seong;Lee, Cheol-Yong;Kim, Ung-Gi;Lee, Jeong-Won;Go, Jin-Hyeon;Lee, Yeong-Ho
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.106-108
    • /
    • 2005
  • The instrumented fuel irradiation test at a research reactor is needed to evaluate the performance of the developed nuclear fuel. The fuel elements can be designed to measure the center line temperature of fuel pellets during the irradiation test by using temperature sensor. The thermal sensor was composed of thermocouple and sensor sheath. Micro-laser welding technology was adopted to seal between seal tube and sensor sheath with thickness of 0.15 mm. The soundness of welding area has to be confirmed to prevent fission gas of the fuel from leaking out of the element during the fuel irradiation test. In this study, fundamental data for micro-laser welding technology was proposed to seal temperature sensor sheath of the instrumented fuel element. And, micro-laser welding for dissimilar metals between sensor sheath and seal tube was characterized by investigating welding conditions. Moreover, the micro-laser welding technology is closely related to advanced industry. It is expected that the laser material processing technology will be adopted to various a pplications in the industry.

  • PDF

Thermal measurement of Geomaterials using Transient Plane Source (비정상면열원법을 이용한 지반물질의 열전달 특성 평가)

  • Kim, Young-Jin;Yun, T.S.
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.45-52
    • /
    • 2010
  • Thermal properties of geomaterial are overlooked with other geomechanical properties. The transient line-source (TLS) method is one of the most used testing methods for measuring the thermal conductivity (K) and thermal diffusivity ($\alpha$) of materials. But more recently, Transient Plane-Source method was developed to measure these. It has several advantage of comparing with TSL method, but there has not been documented application in geomaterial. A Resistance Temperature Detector is used to construct sensor. For durability of Probe, Adopt a new technique that two probes are bonded in exact matching. For standard materials, such as glycerin, and ice the measured K and a values of these materials were generally within 2-5% from the standard values in the literature. This document present to evaluate the thermal properties of geomaterials and its application was tested for varying degree of saturation using the Transient Plane Source method. The result of this study suggests that it is an comparatively accurate method for simultaneously measuring thermal conductivity and thermal diffusivity and can identify the feasibility to geomaterial.

  • PDF

Development of Superconducting Transition Edge Sensors for Gamma Ray Detection (감마선 검출을 위한 초전도 상전이 센서)

  • Lee, Young-Hwa;Kim, Yong-Hamb
    • Progress in Superconductivity
    • /
    • v.9 no.2
    • /
    • pp.162-166
    • /
    • 2008
  • We are developing a sensitive gamma ray spectrometer based on superconducting transition edge sensors. The detector consists of a small piece of high purity Sn as an absorber and a Ti/Au bilayer as a temperature sensor. It is designed to measure the thermal signal caused by absorption of gamma rays. The mechanical support and the thermal contact between the absorber and the thermometer were made with Stycast epoxy. The bilayer was formed by e-beam evaporation and patterned by wet etching on top of a $SiN_X$ membrane. A sharp superconducting transition of the film was measured near 100 mK. When the film was biased to the edge of the transition, signals were observed due to single photon absorption emitted from an $^{241}Am$ source. The measured spectrum showed several characteristic peaks of the source including 59.5 keV gamma line. The full with at half maximum was about 900 eV for the 59.5 keV gamma line. The background was low enough to resolve low energy lines. Considerations to improve the energy resolution of the gamma ray spectrometer are also discussed.

  • PDF

Methane Gas Sensing Properties of the Zinc Oxide Nanowhisker-derived Gas Sensor

  • Moon, Hyung-Sin;Kim, Sung-Eun;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • A low power methane gas sensor with microheater was fabricated by silicon bulk micromachining technology. In order to heat up the sensing layer to operating temperature, a platinum (Pt) micro heater was embedded in the gas sensor. The line width and gap of the microheater was 20 ${\mu}m$ and 4.5 ${\mu}m$, respectively. Zinc oxide (ZnO) nanowhisker arrays were grown on a sensor from a ZnO seed layer using a hydrothermal method. A 200 ml aqueous solution of 0.1 mol zinc nitrate hexahydrate, 0.1 mol hexamethylenetetramine, and 0.02 mol polyethylenimine was used for growing ZnO nanowhiskers. Temperature distribution of the sensor was analyzed by infrared thermal camera. The optimum temperature for highest sensitivity was found to be $250^{\circ}C$ although relatively high (64%) sensitivity was obtained even at as low a temperature as $150^{\circ}C$. The power consumption was 72 mW at $250^{\circ}C$, and only 25 mW at $150^{\circ}C$.

Characteristics of Thermal Coefficient of Fiber Bragg Grating for Temperature Measurement (온도 측정을 위한 광섬유 브래그 격자 센서의 온도 계수 특성 평가)

  • Kim, Heon-Young;Kang, Donghoon;Lee, Jin-Hyuk;Kim, Dae-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.999-1005
    • /
    • 2013
  • A fiber Bragg grating sensor is considered a smart sensor that shows outstanding performance in the field of structural health monitoring (SHM). It has a powerful advantage, especially that of multiplexing, which enables several parameters to be sensed at multiple points by using a single optical fiber line. Among several parameters, the thermal expansion coefficient and thermo-optic coefficient are required to measure temperature. In previous studies, these were considered constant variables. This study shows that two parameters vary with temperature and newly proposes a temperature function for these two parameters. Specifically, these two parameters were defined as a single variable, and then, it was experimentally verified that this variable is a function of temperature. Finally, it was shown that temperature from RT to $100^{\circ}C$ was precisely measured by using the temperature function that was defined through the experiment.

Soft Lithographic Patterning Method for Flexible Graphene-based Chemical Sensors with Heaters

  • Kang, Min-a;Jung, Min Wook;Myung, Sung;Song, Wooseok;Lee, Sun Suk;Lim, Jongsun;Park, Chong-Yun;An, Ki-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.176.2-176.2
    • /
    • 2014
  • In this work, we demonstrated that the fabrication of flexible graphene-based chemical sensor with heaters by soft lithographic patterning method [1]. First, monolayer and multilayer graphene were prepared by thermal chemical vapor deposition transferred onto SiO2 / Si substrate in order to fabrication of patterned-sensor and -heater. Second, patterned-monolayer and multilayer graphene were detached through soft lithography process, which was transferred on top and bottom sides of PET film. Third, Au / Ti (Thickness : 100/30 nm) electrodes were deposited end of the patterned-graphene line by sputtering system. Finally, we measured sensor properties through injection of NO2 and CO2 gas on different temperature with voltage change of graphene heater.

  • PDF

A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body (댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구)

  • Oh, Seok-Hoon;Kim, Jung-Yul;Park, Han-Gyu;Kim, Hyoung-Soo;Kim, Yoo-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF