• 제목/요약/키워드: Thermal Gradient

검색결과 615건 처리시간 0.023초

승용차용 세라믹 촉매 담체의 열적 내구성의 실험적 평가 (Experimental Estimation of Thermal Durability in Ceramic Catalyst Supports for Passenger Car)

  • 백석흠;김성용;승삼선;양협;주원식;조석수
    • 대한기계학회논문집A
    • /
    • 제31권12호
    • /
    • pp.1157-1164
    • /
    • 2007
  • Ceramic honeycomb structures have performed successfully as catalyst supports for meeting hydrocarbon, carbon monoxide and nitrous emissions standards for gasoline-powered vehicles. Three-way catalyst converter has to withstand high temperature and thermal stress due to pressure fluctuations and vibrations. Thermal stress constitutes a major portion of the total stress which the ceramic catalyst support experiences in service. In this study, temperature distribution was measured at ceramic catalyst supports. Thermal durability was evaluated by power series dynamic fatigue damage model. Radial temperature gradient was higher than axial temperature gradient. Thermal stresses depended on direction of elastic modulus. Axial stresses are higher than tangential stresses. Tangential and axial stresses remained below thermal fatigue threshold in all engine operation ranges.

냉동기에 의해 냉각되는 복사열차폐 최적설계 (Design Optimization of Thermal Radiation Shield Cooled by Cryocooler)

  • 최연석;;김동락;양형석;이병섭
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2171-2174
    • /
    • 2008
  • The design of thermal radiation shield cooled by a cryocooler is presented. This study is motivated mainly by our recent development of prototype superconducting magnet system for the Cyclotron K120. The superconducting magnet system is composed of the magnet cryostat, transfer line and supply cryostat. In order to minimize thermal radiation load, the superconducting coil form in the magnet cryostat is enclosed by the thermal radiation shield which is thermally connected to the first-stage cold head of a two-stage cryocooler in the supply cryostat. Since the supply cryostat is located far from the magnet cryostat large temperature gradient along the thermal shield is unavoidable. In this paper, the thermal radiation shield is optimized to minimize temperature gradient with taking into account the cryogenic load, system structure and electrical load. The effect of heat source from thermal conduction through mechanical supports on the temperature distribution of thermal radiation shield is also discussed.

  • PDF

EFFECTS OF PROCESS INDUCED DEFECTS ON THERMAL PERFORMANCE OF FLIP CHIP PACKAGE

  • Park, Joohyuk;Sham, Man-Lung
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 추계기술심포지움논문집
    • /
    • pp.39-47
    • /
    • 2002
  • Heat is always the root of stress acting upon the electronic package, regardless of the heat due to the device itself during operation or working under the adverse environment. Due to the significant mismatch in coefficient of thermal expansion (CTE) and the thermal conductivity (K) of the packaging components, on one hand intensive research has been conducted in order to enhance the device reliability by minimizing the mechanical stressing and deformation within the package. On the other hand the effectiveness of different thermal enhancements are pursued to dissipate the heat to avoid the overheating of the device. However, the interactions between the thermal-mechanical loading has not yet been address fully. in articular when the temperature gradient is considered within the package. To address the interactions between the thermal loading upon the mechanical stressing condition. coupled-field analysis is performed to account the interaction between the thermal and mechanical stress distribution. Furthermore, process induced defects are also incorporated into the analysis to determine the effects on thermal conducting path as well as the mechanical stress distribution. It is concluded that it feasible to consider the thermal gradient within the package accompanied with the mechanical analysis, and the subsequent effects of the inherent defects on the overall structural integrity of the package are discussed.

  • PDF

Wave dispersion analysis of rotating heterogeneous nanobeams in thermal environment

  • Ebrahimi, Farzad;Haghi, Parisa
    • Advances in nano research
    • /
    • 제6권1호
    • /
    • pp.21-37
    • /
    • 2018
  • In the present article, wave dispersion behavior of a temperature-dependent functionally graded (FG) nanobeam undergoing rotation subjected to thermal loading is investigated according to nonlocal strain gradient theory, in which the stress numerates for both nonlocal stress field and the strain gradient stress field. The small size effects are taken into account by using the nonlocal strain gradient theory which contains two scale parameters. Mori-Tanaka distribution model is considered to express the gradually variation of material properties across the thickness. The governing equations are derived as a function of axial force due to centrifugal stiffening and displacements by applying Hamilton's principle according to Euler-Bernoulli beam theory. By applying an analytical solution, the dispersion relations of rotating FG nanobeam are obtained by solving an eigenvalue problem. Obviously, numerical results indicate that various parameters such as angular velocity, gradient index, temperature change, wave number and nonlocality parameter have significant influences on the wave characteristics of rotating FG nanobeams. Hence, the results of this research can provide useful information for the next generation studies and accurate deigns of nanomachines including nanoscale molecular bearings and nanogears, etc.

광섬유 격자 센서를 이용한 모르타르시편의 온도구배 및 열 변형 측정 (Measurements of Thermal Gradient and Thermal Strain of Mortar Specimens Using Fiber Bragg Grating Sensor)

  • 임홍철;이은주;전흥재;박동녘
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.133-138
    • /
    • 2003
  • FBG sensor의 다중 측정성을 이용하여 모르타르 시편의 열 변형률과 온도 변화를 동시에 측정하였다. 또한, 광섬유 격자 센서를 이용하여, 열 변화에 따른 모르타르 시편의 내부 온도 구배를 측정하였다. 열 변형률을 기존 strain gauge와 함께 측정하였을 때, strain gauge는 섭씨 60도 이상의 온도에서 오차를 보이는 반면, FBG 센서는 안정된 측정값을 나타냈다. FBG 온도 sensor로 측정한 온도 변화량은 thermocouple로 측정한 값과 비교하였으며, 선형적인 대응관계를 보였다.

다공성 물질의 열 및 습도 전달에 관한 유한요소 해석 (Finite Element Analysis of Heat and Moisture Transfer in Porous Materials)

  • 이호림;금영탁;송창섭;오근호
    • 한국정밀공학회지
    • /
    • 제16권7호
    • /
    • pp.158-167
    • /
    • 1999
  • Heat and moisture transfer associated with porous materials are investigated. The heat and moisture transfer in porous materials caused by the interaction of moisture gradient, temperature gradient, conduction, and evaporation are considered. The variations of temperature and moisture not only change the volume but also induce the hygro-thermal stress. The finite element formulation for solving the temperature and moisture transfer as well as the associated hygro-thermal stresses is developed. In order to verify the finite element formulation, the heat and moisture moving boundary problem in a half space and the hygro-thermo-mechanical problem in an infinite plate with a circular hole are analyzed. Temperature profile, moisture profile, and hygro-thermal stresses are compared with those of analytic solution and other investigator. Good agreements are examined

  • PDF

양단온도차에 의한 직각용기내 자연대류에 미치는 안정온도구배의 영향 (Effects of Stabilizing Thermal Gradients on the Natural Convection in Rectangular Enclosures due to Lateral Temperature Difference)

  • 김무현
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.365-375
    • /
    • 1991
  • Confined natural convection due to lateral temperature difference in rectangular enclosures was studied numerically and experimentally for the insulated and the constant temperature enclosures. In the case of insulated enclosure, the flow pattern and heat transfer modes are rather simple depending mainly upon Rayleigh number. In the case of isothermal enclosure, however, the phenomena of flow and heat transfer are somewhat complex and interesting due to the stable thermal gradients and various circumstances resulted from four wall temperature conditions. As a dimensionless variable, to describe properly the flow and heat transfer phenomena in the isothermal enclosure, temperature difference ratio ${\Delta}T_v/{\Delta}T_H$ is newly introduced and this parameter seems to be appropriate in the analysis of results on the effect of stabilizing thermal gradient.

  • PDF

레이저 플래쉬 방법에 의한 SiC/C계 경사기능재료의 열물성 측정 (Measurement of Thermal Properties of SiC/C Functionally Gradient Materials by Laser Flash Method)

  • 목재균;유재석
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1679-1688
    • /
    • 1996
  • Laser flash technique was applied to measure thermal properties of FGM made by a CVD method. System stability and reproducibility of this measuring system were proved and calibrated with glassy carbon used as reference material. Specimens was prepared by cutting FGM diagonally. Measurements were performed for a wide range of temperatures up to 1500K. Relative heat capacity of the FGM specimen was scattered with in $\pm$13% at room temperature and at high temperature above 1200K, and $\pm$3% at medium temperature range. On the other hand, thermal diffusivity data showed excellent reproducibility and stability through the whole temperature range. In conclusion, the multi-target radiometer can be applied to measure the thermal properties of non homogeneous materials like FGM.

구배두께를 이용한 대류열전달의 재해석 (An Alternative Use of the Heat Transfer Coefficient in Terms of the Gradient Thickness)

  • 김찬중
    • 대한기계학회논문집B
    • /
    • 제24권12호
    • /
    • pp.1678-1682
    • /
    • 2000
  • In this article, the concept of gradient thickness is further extended to characterize the gradient behavior of the thermal and momentum boundary layer near a solid surface. The gradient thickness can replace the use of the conventional of the Nusselt and Reynolds numbers in terms of the gradient thickness provides a much easier grasp of the physical and practical meaning of the processes involved. Although there is no urgent need to discard the concept of the conventional convective heat transfer coefficient, the concept of the gradient thickness is believed to serve an efficient tool in helping students understand physics.

지하수류가 밀폐형 천공 지중 열교환기 성능에 미치는 영향(2) (An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-2))

  • 한정상;김영식;이주현;이병호;한찬
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제21권6호
    • /
    • pp.114-127
    • /
    • 2016
  • An increase of groundwater flux in BHE system creates that ground temperature (locT) becomes lower in summer and higher in winter time. In other words, it improves significantly the performance of BHE system. The size of thermal plume made up by advection driven-flow under the balanced energy load is relatively small in contrast to the unbalanced energy load where groundwater flow causes considerable change in the size of thermal plume as well ground temperature. The ground temperatures of the up gradient and down gradient BHEs under conduction only heat transport are same due to no groundwater flow. But a significant difference of the ground temperature is observed between the down gradient and up gradient BHE as a result of groundwater flow-driven thermal interference took placed in BHE field. As many BHEs are designed under the obscure assumption of negligible groundwater flow, failure to account for advection can cause inefficiencies in system design and operation. Therefore including groundwater flow in the design procedure is considered to be essential for thermal and economic sustain ability of the BHE system.