• 제목/요약/키워드: Thermal Estimation

검색결과 583건 처리시간 0.025초

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.

장축 실린더의 열변형 최소화를 위한 차열관 효과 해석 및 실험 연구 (An Analytical and Experimental Study on the Thermal Shroud Effect to Minimize Thermal Deformation of a High L/D Ratio Cylinder)

  • 안상태
    • 한국유체기계학회 논문집
    • /
    • 제10권5호
    • /
    • pp.54-63
    • /
    • 2007
  • A barrel is a high length-to-diameter ratio cylinder that is influenced by environmental factors such as sunlight, precipitation, wind and clouds. Cross-barrel temperature differences caused by uneven heating or cooling lead to thermal deformation that degrades accuracy. Therefore, a barrel is covered by thermal shrouds to minimize the type of thermal deformation, "fall-of-shot". In this paper, an analytical and experimental study is presented to design the thermal shrouds for a gun barrel and to evaluate the thermal shroud effect. First, an analytical study on the thermal shroud effect to minimize thermal deformation of a gun barrel by sunlight and wind is performed. The coupled analysis of thermal fluid dynamics of the air flow between a barrel and thermal shrouds and thermal stresses of a barrel Is performed to clarify both the thermal shroud effect and the drift in gun muzzle orientation by thermal deformation. Second, experiments are carried out to test and evaluate the thermal shroud effect on the performance of a gun barrel. The drift in gun muzzle orientation against the solar radiation is confirmed by the experiments, and the results well agree with the analytical estimation. Third, three principal design factors that are presumed to have an effect on the performance of the thermal shrouds are also analyzed; sorts of shroud materials, wall-thickness of thermal shrouds, and distance of the gap between a barrel and thermal shrouds.

액체금속로 Y-구조물의 비탄성 열응력 해석 및 손상평가에 관한 유한요소해석 (Finite element analysis of inelastic thermal stress and damage estimation of Y-structure in liquid metal fast breeder reactor)

  • 곽대영;임용택;김종범;이형연;유봉
    • 대한기계학회논문집A
    • /
    • 제21권7호
    • /
    • pp.1042-1049
    • /
    • 1997
  • LMFBR(Liquid Metal Fast Breeder Reactor) vessel is operated under the high temperatures of 500-550.deg. C. Thus, transient thermal loads were severe enough to cause inelastic deformation due to creep-fatigue and plasticity. For reduction of such inelastic deformations, Y-piece structure in the form of a thermal sleeve is used in LMFBR vessel under repeated start-up, service and shut-down conditions. Therefore, a systematic method for inelastic analysis is needed for design of the Y-piece structure subjected to such loading conditions. In the present investigation, finite element analysis of heat transfer and inelastic thermal stress were carried out for the Y-piece structure in LMFBR vessel under service conditions. For such analysis, ABAQUS program was employed based on the elasto-plastic and Chaboche viscoplastic constitutive equations. Based on numerical data obtained from the analysis, creep-fatigue damage estimation according to ASME Code Case N-47 was made and compared to each other. Finally, it was found out that the numerical predictio of damage level due to creep based on Chaboche unified viscoplastic constitutive equation was relatively better compared to elasto-plastic constitutive formulation.

초기 지중온도 측정이 지중 열교환기 설계에 미치는 영향 (Effect of initial ground temperature measurement on the design of borehole heat exchanger)

  • 송윤호;김성균;이강근;이태종
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.600-603
    • /
    • 2009
  • We compared relative importance of thermal conductivity and initial ground temperature in designing borehole heat exchanger network and also we test accuracy of ground temperature estimation in thermal response test using a proven 3-D T-H modeler. The effect of error in estimating ground temperature on calculated total length of borehole heat exchanger was more than 3 times larger than the case of thermal conductivity in maximum 20% error range. Considering 10% of error in estimating thermal conductivity is generally acceptable, we have to define the initial ground temperature within 5% confidence level. Utilizing the mean annual ground surface temperature and the geothermal gradient map compiled so far can be a economic way of estimating ground temperature with some caution. When performing thermal response test for estimating ground temperature as well as measuring thermal conductivity, minimum 100 minutes of ambient circulation is required, which should be even more in case of very cold and hot seasons.

  • PDF

CCD 카메라를 이용한 열화상 실시간 추정과 화재경보 (Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera)

  • 백동현
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.92-98
    • /
    • 2016
  • 본 논문은 Charge-Coupled Device (CCD) 카메라를 이용한 열화상의 실시간 추정과 화재경보에 대하여 논한 것으로 각도 및 위치에 따른 특징점 분석과 동일 형상의 벡터 성분 좌표점 설정에 따른 이미지 융합이 잘 되었다. 영상을 Display하는 픽셀의 데이터 값은 0~255, 센서 출력값은 0~5,000로 하여 정확성이 높았다. 시험결과 시험체로부터 500 m, 1000 m, 1500 m 거리에서 화염에 의한 시험체의 작동시간은 각각 7초, 26초, 62초 소요 되었고 화면이미지 생성이 효과적으로 이루어졌다. 화재 발생 진단은 주의/경보/화재의 3단계로 프로그램하여 Alarm의 순차적 동작과 SNS 전송이 이루어졌다. 비화재보시험을 위해 백열등, 형광등에 대해 시험하였으나 모두 비화재보를 발생하지 않았다. 시간대별 화염의 변화영상과 진행방향 및 확산속도의 분석은 화재진행상황 예측이나 열화상 실시간 추정과 경보로 비화재보 감소가 가능함을 확인하였다.

NUMERICAL STUDY FOR THE PARAMETER ESTIMATION OF THE MOISTURE TRANSFER COEFFICIENT : 2D CASE

  • Lee, Yong-Hun;Park, Yeon-Hee
    • Journal of applied mathematics & informatics
    • /
    • 제29권5_6호
    • /
    • pp.1257-1268
    • /
    • 2011
  • The thermal behavior of wood exposed to the outdoors is influenced by solar absorptivity and longwave emissivity. However, it is difficult to measure that properties directly. Hence we estimate the values of the parameter by using the least-square optimization technique. Finally we report the results for the computation of the values of the parameters.

화력발전소 보일러 제어루프의 시뮬레이션에 관한 연구 (A Study of Boiler Control Loop Simulation in Thermal Power Plant)

  • 이주현;이찬주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.868-870
    • /
    • 1999
  • In this paper we obtain a discrete mathmatical model of a Boiler control system from expermental data, we find appropriate input signal and parameter estimation algorithm for identification of the Boiler control system in power plant. Under these conditions experimental data are collected from real system and parameters are estimated by the Recursive Least Square algorithm. The computer simulation results show the parameter estimation algorithm for identification and the effectiveness of controller design of the Boiler control system.

  • PDF

속도센서없는 벡터제어시 회전자저항 추정에 의한 속도오차보상 (Speed Error Compensation By Rotor Resistance Estimation in Sensor-less Vector Control)

  • 김준석;목형수;김희욱;박민호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.326-331
    • /
    • 1990
  • In the vector-controlled induction machine drive, mechanical sensors restrict the wide applications of high performance AC drives. So in resent years, many papers have been presented which doesn't need mechanical sensors, named by sensorless vector control. But sensorless control has a few serious problem, one of which Is poor speed estimation in case of incorrect rotor resistance (Rr) information. This paper describes the stator flux orientation speed control strategy with the speed estimation algorithm. and the method of adapting Rr change due to thermal heating. By proposed method. We can acquire precise speed estimation and higher performance.

  • PDF