• Title/Summary/Keyword: Thermal Control Unit

Search Result 166, Processing Time 0.035 seconds

Degradation Behavior of Solder Joint and Implementation Technology for Lead-free Automotive Electronics (자동차 전장제품의 무연솔더 적용기술 및 솔더 접합부 열화거동)

  • Hong, Won Sik;Oh, Chul Min
    • Journal of Welding and Joining
    • /
    • v.31 no.3
    • /
    • pp.22-30
    • /
    • 2013
  • Due to ELV banning, automotive electronics cannot use four kinds of heavy metal element (Pb, Hg, Cd, $Cr^{6+}$) from 2016. Therefore, this study was focused on degradation characteristics of Sn-3.0Ag-0.5Cu Lead-free solder joint with OSP and ENIG finsh under various reliability assessment method, as like to thermal shock test and high temeprature/high humidity test with test duration for cabin electronics. Also, we compared bonding strength degradation to other advanced research results of electronic control unit for engine room because of difference service temperature with mount location in automotive. Whisker growth phenomenon and mitigation method which were essentially consideration items for Pb-free car electronics were examined. Conformal coating is a strong candidate for mitigating whisker growth in automotive electronics. Necessary condition to adapt Pb-free in car electronics was shown.

A Study on the Function Improvement of the Serge Protection Device for Radar Control Unit (레이더장비에 적용되는 저압전력계통의 서지보호장치 기능개선에 관한 연구)

  • Jo, Hee-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.400-407
    • /
    • 2016
  • The purpose of this study is to propose a useful method of solving the problem of thermal stability in surge protection devices (SPDs). First of all, the existence of the problem in the developed SPDs was confirmed by experiment. After analyzing the problem, a useful method of solving it is proposed and implemented. An experiment is performed to verify the performance of the implemented device. The results of this study are as follows; it is revealed that the problem of the thermal stability results from the varistor, one of the components in the SPD. A varistor with a built-in thermal fuse is applied to the SPD for the purpose of solving the problem. The experimental results confirmed that the thermal stability was improved by replacing the varistor. As a result of this study, the reliability of radar control units is enhanced and the probability of malfunction is reduced.

Operation Results and Utility of Dynamic Pricing Response Control-Applied VRF System in Summer Season

  • Kim, Min-seok;Lee, Je-hyeon;Song, Young-hak
    • Architectural research
    • /
    • v.19 no.3
    • /
    • pp.71-77
    • /
    • 2017
  • Dynamic pricing refers to a system in which a tariff varies, according to a level of charging and applied time depending on time change. The power billing system used in the Korean Electric Power Corporation (KEPCO) is based on time of use (TOU) pricing, which is one of the dynamic pricing systems. This paper aimed to determine the operational results of a variable refrigerant flow system, to which a new control algorithm was applied, in order to respond to dynamic pricing, in summer and the utility of the new control. To do this, real measured data was acquired from a VRF system installed in a building for educational purposes, where dynamic pricing was applied for about 100 days during summer time. At the maximum load operation time period in TOU, the new control minimized operation within the indoor comfort range, an increase in refrigerant evaporation temperature in the indoor unit and the number of revolutions in a compressor in the outdoor unit was limited. As a result, power usage was decreased by 11%, and the operational cost by 14.6%. Furthermore, measurement results using the Predicted Mean Vote (PMV) model, that represented satisfaction of thermal environment, showed that 82.8% to 90.4% of the occupants of the building were satisfied during operation when the new control was applied.

The Development Of Program Based On Model to Control Generator Output in Power Plant (모델 기반의 화력발전소 발전기 출력 제어 프로그램 개발)

  • Lim, Geon-Pyo;Kim, Mun-Soo;Choi, In-Kyu;Park, Doo-Yong;Kim, Ho-Yol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.614-622
    • /
    • 2010
  • The goal of this paper is to develope the control program based on model which can be applied to 1000MW class coal fired thermal power plant. 1000MW class power plant has the higher efficiency and lower cost because the steam conditions of the ultra super-critical process are higher than them of the previous power plants in temperature and pressure. The program includes the state variable controls which have the desired characteristics for the higher temperature and pressure. The program had been developed successfully using advanced process control. The simulation results using the new control program showed the better performance and safer control than them of the previous control program and we could verify the application possibility of the new program for the actual power plant through the load test, comparison, analysis and tuning.

Reliability Verification of Battery Disconnecting Unit (BDU 신뢰성 검증)

  • Yoon, Hye-Lim;Ryu, Haeng-Soo;Ji-Hong;Hong-Tae, Park
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.866-867
    • /
    • 2011
  • As part of the green growth, The Green Car has attracted wide attention. Types of the Green Car are Electric Vehicle, Plug-in Hybrid Electric Vehicle, Hybrid Electric Vehicle, Fuel Cell Vehicle and Clean Diesel Vehicle. Of these, The electric vehicle is equipped with the BDU(Battery Disconnecting Unit). BDU is supplying stable battery power and blocking it to protect electrical system of the electric vehicle. The BDU consists of electric components such as current sensor, fuse and pre-charge resistor. These must pass Voltage withstand test, Salt mist test, Thermal shock test, Vibration test and Short-circuit test commonly to verify reliability of the electric components. In addition, The current sensor should be verified whether normal operation. The breaking capacity of fuse should be verified. The durability of pre-charge resistor should be verified by supplying battery power and blocking it repeatedly. The reliability of BDU as well as the electric vehicle is secured by verifying the reliability of electric components. In addition, It will contribute to the acceleration and promotion of Green Car Technology.

  • PDF

Measurement and Simulation of Heating Energy for Apartments with District Heating (지역난방 아파트에 대한 난방에너지 실측 및 시뮬레이션)

  • Lee, Eun Ju;Lee, Doo Young;Hong, Hiki;Kim, Young Kyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.572-578
    • /
    • 2014
  • Heating energy was measured in an apartment housing unit with a district heating system, varying the kind of hot water distributors. Ondol coils passing through a living room raised the temperature of the room where the heating was turned off. Including this characteristic of Ondol heating into the modeling, we performed simulations and showed a verification by comparison with the results of measurements. As a result, a main flow control method, which changes hot water flow rate supplied to a housing unit according to the thermal load, can reduce the supplied flow rate and lower the return temperature, compared with a constant flow method. That can result in decreased heat loss in utility-pipe conduits even though the heating energy supplied is almost the same. An outdoor reset control that raises the temperature of the supplied hot water if the outdoor temperature falls has the effect of a quicker response in heating than the reduced flow rate and return temperature.

Evaluation of Energy Consumption through Field Measurement at the Apartment Housing Unit Using Dynamic Flow Rate Balancing (실물실험을 통한 다이나믹 유량밸런싱 적용 공동주택 세대의 에너지소비량 평가)

  • Ryu, Seong-Ryong;Cheong, Chang-Heon;Cho, Hyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.4
    • /
    • pp.15-20
    • /
    • 2016
  • Even though the control device of the heating system works well, insufficient water flow rates can degrade control performance and thermal comfort. The water flow rate should be adjusted appropriately to cope with the heating load of each zone. In order to solve these problems, a new balancing concept 'dynamic balancing' was proposed where a balancing valve opening can be automatically modulated according to the heating condition of the room. This study analyzed the effects of dynamic balancing upon indoor thermal environment and energy consumption in a radiant floor heating system through field measurement. Under part-load conditions, the use of a dynamic balancing is a more effective method to reduce energy consumption and to prevent a cavitation. Dynamic balancing is able to help boost the temperature of a room in the start-up period.

Microbiological Changes of Marinated Broiler Drumsticks Treated with the Lactoperoxidase System and with or without Thermal Treatment

  • Tan, Fa-Jui;Ockerman, Herbert W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.1
    • /
    • pp.109-112
    • /
    • 2006
  • The objective of this study was to evaluate the combined effects of lactoperoxidase system (LPS), thermal treatment and storage time on total microflora and psychrotrophs counts of the marinated broiler drumsticks. A marinade that contained acetic acid (1%) and salt (3%) with pH adjusted to 4 was developed as a standardized marinade. Drumsticks were marinated with various LPS levels, combined with thermal treatment (4 or $58^{\circ}C$ for 2 min), and then stored at $4^{\circ}C$ for 18 h. The microbial counts of the samples were measured after 0, 2, 4 and 7 days of storage for drumsticks held at $4^{\circ}C$. The results indicate that adding LPS at the level of 1 unit ($1{\mu}g/ml$ LP, 5.9 mM KSCN, and 2.5 mM $H_2O_2$) significantly (p<0.05) decreased the total microflora and psychrotrophs counts of the marinated broiler drumsticks. In addition, samples treated with a thermal treatment ($58^{\circ}C$ for 2 min) had significantly (p<0.05) lower microbial counts when compared with the control.

Comparison of Thermal Comfort Performance Indices for Cooling Loads in the Lecture Room - An Correlation of PMV Bnd EDT - (강의실에서의 냉방부하에 따른 열쾌적성 평가지표 비교 - PMV와 EDT의 연관성 -)

  • Noh Kwang-Chul;Oh Myung-Do
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.868-877
    • /
    • 2005
  • We performed the experimental and the numerical study on the comparison of thermal comfort performance indices for cooling loads in the lecture room for 4 cases: Fan coil unit(FCU) or 4-way cassette air-conditioner is respectively operated with the ventilation system or without. We measured the velocity, the temperature distribution and predicted mean vote(PMV) value in the lecture room for 4 different air-conditioning methods. Effective draft temperature(EDT) and PMV were investigated to analyze the characteristics of two thermal comfort indices in the lecture room and to compare their values each other. From the results we knew that there is the similarity between PMV values and EDTs when the room is air-conditioned for cooling loads. It turned out that definition of the control temperature is very important when the EDT is calculated. Finally EDT should not be used to predict the accurate thermal comfort in case that the temperature and humidity are suddenly varied and the zone affected by the solar and inner wall radiation.

Catalytic Technologies for Nitric Acid Plants N2O Emissions Control: In-Duct-Dependent Technological Options (질산제조 플랜트 N2O 제거용 촉매기술: 적용위치별 기술옵션)

  • Kim, Moon-Hyeon
    • Journal of Environmental Science International
    • /
    • v.21 no.1
    • /
    • pp.113-123
    • /
    • 2012
  • A unit emission reduction of nitrous oxide ($N_2O$) from anthropogenic sources is equivalent to a 310-unit $CO_2$ emission reduction because the $N_2O$ has the global warming potential (GWP) of 310. This greatly promoted very active development and commercialization of catalysts to control $N_2O$ emissions from large-scale stationary sources, representatively nitric acid production plants, and numerous catalytic systems have been proposed for the $N_2O$ reduction to date and here designated to Options A to C with respect to in-duct-application scenarios. Whether or not these Options are suitable for $N_2O$ emissions control in nitric acid industries is primarily determined by positions of them being operated in nitric acid plants, which is mainly due to the difference in gas temperatures, compositions and pressures. The Option A being installed in the $NH_3$ oxidation reactor requires catalysts that have very strong thermal stability and high selectivity, while the Option B technologies are operated between the $NO_2$ absorption column and the gas expander and catalysts with medium thermal stability, good water tolerance and strong hydrothermal stability are applicable for this option. Catalysts for the Option C, that is positioned after the gas expander thereby having the lowest gas temperatures and pressure, should possess high de$N_2O$ performance and excellent water tolerance under such conditions. Consequently, each de$N_2O$ technology has different opportunities in nitric acid production plants and the best solution needs to be chosen considering the process requirements.