• 제목/요약/키워드: Thermal Control System

검색결과 1,274건 처리시간 0.031초

Analysis of Supply Airflow Control by a Stratified Thermal Model in a VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Cho, Hyung-Hee
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권3호
    • /
    • pp.46-56
    • /
    • 2001
  • The present study concerns the numerical simulation of a supply airflow control in a variable air volume (VAY) system. A stratified thermal model (multi-zone model) is suggested to predict a local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of an air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated. Further, the influence of control parameters such as the supply air temperature, the PI control factor and the thermostat location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (single zone model) may overestimate the time taken to the set point temperature. It is also found that there exist the appropriate ranges of the control parameters for the optimal airflow control of the VAV system.

  • PDF

화력 발전소 보일러 제어 시스템의 구성에 관한 연구 (Configuration of a Boiler Control System in Thermal Power Plant)

  • 변승현;박두용;김병철;신만수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.168-168
    • /
    • 2000
  • In this paper, a boiler control system for thermal power plant is configured. The boiler control system for thermal power plant is largely composed of an ABC(Automatic Boiler Control) system and a MBC(Mill Burner Control) system. ABC system controls analog process values, so almost all analog control logic is dealt with in ABC system. On the other hand, MBC system relates to sequence control logic such as MFT logic, Furnace Purge, Safety related logic. Advanced control systems made from advanced countries deal with an ABC system and MBC system in a distributed control system. In this paper, we adopt a DCS as an ABC system and adopt a PLC system as a MBC system to configure a boiler control system for thermal power plant using domestic control system. Finally the validity of the configured boiler control system is shown via simulation using digital simulator for boiler system in thermal power plant.

  • PDF

적응제어방식 성능비교를 위한 실험실용 프로세스의 제작 및 실험 (Manufacture and experiments of thermal process for comparative study of adaptive control)

  • 주성준;공재섭;박용식;김영철;양홍석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.333-338
    • /
    • 1990
  • Most verification of improvements for adaptive control schemes are. dependent on computer simulations, but these computer simulations have much limitation, because (if complex actual conditions of system. This paper is concerned with the constructions of a thermal process system for experiments with various control schemes. This thermal process system is composed of a water tank, PC-XT, AD/DA converters power supply and thermal sensors. We estimate. the algorithms of pole-assignment adaptive control in the manifold disturbances and environments, changing system dynamics. The system equations for thermal press are included.

  • PDF

An Experimental Measurement on Transient Thermal Response in a PI-Controlled VAV System

  • Kim, Seo-Young;Moon, Jeong-Woo;Kim, Won-Nyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권1호
    • /
    • pp.10-16
    • /
    • 2003
  • The present study performs an experimental measurement on transient thermal response of an air-conditioned space by a variable air volume (VAV) system with a PI(pro-portional-integral) control logic. A thermal chamber with a PI controlled VAV unit is constructed to verify the previously suggested stratified multi-zone model. The effects of thermal parameters and control parameters such as supply air temperature and PI control factor are investigated by implementing the thermal chamber test. The experimental results obtained show that transient behavior of the air-conditioned space-temperature is in good accordance with the simulation results of the stratified thermal model.

성층화 열용량 모델을 이용한 VAV 시스템 급기 제어 시뮬레이션 (Simulation of Supply Air Control in a VAV System Using a Stratified Lumped Thermal Model)

  • 문정우;김서영;김원년;조형희
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.632-641
    • /
    • 2000
  • The present study concerns the simulation of supply-air control in a variable air volume (VAV) system. A stratified lumped thermal model (multi-zone model) is suggested to predict local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated in detail. Further, the influence of control parameters, PI control factor and the sensor location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (1-zone model) may predict a significantly different thermal response in the air-conditioned space according to the sensor location.

  • PDF

태양열발전 제어시스템 (A Control System for Solar Thermal Power Plant)

  • 박영칠
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.693-697
    • /
    • 2007
  • A control system for solar thermal power plant is the control system to coordinate the whole system's operation, including management of distributed control systems, process control for optimal operation of total system, monitoring system operating conditions and doing administrative functions. This work, as a progress report, presents the results obtained so far in building a control system for the 1MW solar thermal power plant. To make the control system, we first defined the control system's hierarchy and classified the role of each layer. Then, as the first stage of making control system, we designed and developed the sun tracking control system for heliostat.

  • PDF

고속 Thermal Printer의 무선원격제어장치 개발 (The development of RF Control System For the High-Speed Thermal Printer)

  • 우천희;한태환
    • 전기학회논문지P
    • /
    • 제53권2호
    • /
    • pp.94-99
    • /
    • 2004
  • In this paper, We design a RF control system capable of handling multiple POS thermal printers. The system has three parts including embedded master controller, RF controller and high-speed thermal printer. Specially the designed linux embedded controller has simple structure and high performance to connect the TCP/IP network. The effectiveness of the developed RF control system is shown by proposed food ordering system.

유량제어방식에 따른 태양열 급탕시스템의 열성능 평가 (Thermal Performance Evaluation of Solar Hot Water System according to Flow Rate Control)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.140-145
    • /
    • 2011
  • In this study, the performance and behavior of solar heating system according to the system control scheme, variable flow control (proportional control) and constant flow control (on-off control) was carried out by experiment. The on-off control is used generally for solar thermal system by now. But the proportional control is used for the solar district heating system which is supplied the higher temperature of water than that of desired. The proportional control logic that pump speed is varied in an attempt to maintain a specified outlet temperature of solar heating system was developed and tested for the use widely for the small and medium solar thermal system. The results are as following. First, the proportional controller which is made here could be adopted the characteristics for setting temperature control. Second, the proportional control is better than the on-off control in the side of the performance of thermal stratification in storage tank. Third, the operating energy(electricity consumption by pump) of solar thermal system can be saved more than 60% using the proportional control comparing to the on-off control.

HAUSAT-2의 궤도 열해석과 열제어계의 예비설계 (THE ORBITAL THERMAL ANALYSIS OF HAUSAT-2 AND ITS THERMAL CONTROL SUBSYSTEM PRELIMINARY DESIGN)

  • 이미현;김동운;장영근
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2005년도 한국우주과학회보 제14권1호
    • /
    • pp.129-132
    • /
    • 2005
  • 본 논문에서는 HAUSAT-2의 궤도 열 해석과 열 제어계의 예비설계를 살펴본다. HAUSAT-2의 열 제어계를 설계하기 위해서 우선 열 제어의 기본 이론 및 열 평형 방정식을 바탕으로 능동 및 수동의 각종 열 제어 방법을 고려하여 HAUSAT-2에 적합한 열 제어 방법 및 재질을 선정하였다(Karam 1998). 또한, 예상궤도인 고도 650km, 경사각 $98^{\circ}$의 태양동기궤도에서 HAUSAT-2가 처해지는 열 환경에 대한 분석 및 위성체의 각 면에 가해지는 은도 분포 및 범위를 예측하여 이를 바탕으로 열 제어계를 설계하였다. 열 해석은 기본적으로 시스템레벨의 해석, 부품레벨의 해석, 보드레벨의 해석 차순으로 진행되었으며, 현재 HAUSAT-2의 열 해석은 발열이 비교적 많은 보드의 해석까지 진행된 상태이며, 이러한 열 해석을 통해서 얻은 결과는 요구조건을 만족하지 못하는 부분에 대해 설계 변경 등을 통해서 모든 부품이 허용온도 범위를 유지하도록 HAUSAT-2의 열 제어계를 설계하였다. 향후 구조-열 모델(STM; Structure & Thermal Model)을 제작한 후 열 진공시험을 통해 열 해석 결과에 대한 검증을 수행할 것이다.

  • PDF

중합효소연쇄반응 기기의 온도 사이클링 제어시스템 설계 (Thermal Cycling Control System Design for Polymerase Chain Reaction(PCR) Machine)

  • 김종해;조용석;오도창
    • 제어로봇시스템학회논문지
    • /
    • 제12권5호
    • /
    • pp.419-424
    • /
    • 2006
  • In this study, a thermal control system which applied a Peltier device for the polymerase chain reaction(PCR) machine is to be designed. Here in order for it to easily follow the characteristics of the thermal cycle existing for gene amplification of the PCR sample, a PCR control board utilizing a thermal sensor, a Peltier, and a 8 bit microprocessor is made up. Especially a fuzzy type PD control algorithm is applied periodically in time response, and control system is implemented. For that matter, the characteristic data of subject system is obtained and analysed to begin with. Based on this analysed data, the proposed control algorithm is applied and an evaluation of the performance of the whole system take place through the PC.