• Title/Summary/Keyword: Thermal Control

Search Result 3,099, Processing Time 0.033 seconds

A Study on the Control of Thermal Crack of the Mat Foundation (매트기초의 온도균열 제어에 관한 연구)

  • 이도범;김효락;박지훈;최일호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.305-308
    • /
    • 2003
  • Recently, a structure has been large and high under the improvement of construction technique. So, mass concrete constructions that a mat foundation thickness of structure is over 80cm have been many. Also, in the reason of high strength of concrete, a matter of thermal crack became an important task to be solved. In this study, we executed temperature and stress analysis of mat foundation. And we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis program. Because of this analysis technique, we could control skilfully the quality of mat foundation in a construction.

  • PDF

Ceramic Coating by Electron Beam PVD for Nanos-Tructure Control (나노구조 제어를 위한 EB-PVD법에 의반 세라믹스 코팅)

  • Matsbara, Hideaki
    • Ceramist
    • /
    • v.9 no.6
    • /
    • pp.24-29
    • /
    • 2006
  • Electron beam physical vapor deposition (EB-PVD) process has currently been applied to thermal barrier coatings (TBCs) for aircraft engines. Due to unique columnar structure, EB-PVD TBCs have advantages in resistances to thermal shock and thermal cycle for their applications, compared to films prepared by plasma spray By the EB-PVD equipment, we successfully obtained yttria-stabilized zirconia (YSZ) layer which has columnar and feather like structure including a large amount of nano size pores and gaps. The EB-PVD technique has been developed for coating functional perovskite type oxides such as (La, Sr)MnO3. Electrode properties have been improved by interface and structural control.

  • PDF

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

Efficient Control of an Air Conditioner Using Thermal Image and a Fuzzy Control Method (퍼지 제어 기법과 열 영상을 이용한 에어콘의 효율적 제어)

  • Kim, Kwang-Baek;Woo, Youn-Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2201-2206
    • /
    • 2010
  • The shortage of fossil fuel drives researchers to find a new way to increases energy efficiency. In this paper, we propose a method to control the direction and speed of an air conditioner using a thermal image and fuzzy controlling method, which results in the increase of energy efficiency. The thermal image is first converted into a color temperature image which represents the temperature range from $24.0^{\circ}C$ to $27.0^{\circ}C$. The temperature image is divided into 5 columns and the distribution of them is used to analyze room temperature and control an air conditioner. The proposed method was applied to 300 by 400 thermal images. When the performance of the proposed method was compared to existing systems in energy efficiency, the proposed method was better than existing methods, which is clear from experimental results.

A thermal stress and crack study by computer modelling (전산해석에 의한 온도응력 및 온도균열 검토)

  • 문수동;이상호;문한영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.375-380
    • /
    • 2002
  • Tong-young LNG tank is a LNG storage tank of 140,000 kl, and it is composed of Bottom Slab(Annular, Center), Outer Wall, Ring Beam and Roof. Generally, when concrete temperature arise, the complex thermal stress of inner and outer part can cause serious thermal crack and damage at structure. So in this paper, for the control of this thermal crack, we did the concrete mix design with the base of fly-ash 30% substitute at binder, and through the computer modelling at Bottom Slab(Annular, Center), Outer Wall, Ring Beam and Roof, we studied the probability of thermal crack by thermal crack index.

  • PDF

Development of Variable Duty Cycle Control Method for Air Conditioner using Artificial Neural Networks (신경회로망을 이용한 에어컨의 가변주기제어 방법론 개발)

  • Kim, Hyeong-Jung;Doo, Seog-Bae;Shin, Joong-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.10
    • /
    • pp.399-409
    • /
    • 2006
  • This paper presents a novel method for satisfying the thermal comfort of indoor environment and reducing the summer peak demand power by minimizing the power consumption for an Air-conditioner within a space. Korea Electric Power Corporation (KEPCO) use the fixed duty cycle control method regardless of the indoor thermal environment. However, this method has disadvantages that energy saving depends on the set-point value of the Air-Conditioner and direct load control (DLC) has no net effects on Air-conditioners if the appliance has a lower operating cycle than the fixed duty cycle. In this paper, the variable duty cycle control method is proposed in order to compensate the weakness of conventional fixed duty cycle control method and improve the satisfaction of residents and the reduction of peak demand. The proposed method estimates the predict mean vote (PMV) at the next step with predicted temperature and humidity using the back propagation neural network model. It is possible to reduce the energy consumption by maintaining the Air-conditioner's OFF state when the PMV lies in the thermal comfort range. To verify the effectiveness of the proposed variable duty cycle control method, the case study is performed using the historical data on Sep. 7th, 2001 acquired at a classroom in Seoul and the obtained results are compared with the fixed duty cycle control method.

Thermal Compensation Circuit with Improved Compensation Characteristic for Power Amplifier (개선된 보상특성을 갖는 증폭기용 온도보상회로)

  • Jung, Young-Bae
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.177-181
    • /
    • 2012
  • This paper introduces a thermal compensation circuit with improved compensation characteristic for amplifiers to provide stable output power regardless environmental temperature. The proposed thermal compensation circuit is composed of two branchline couplers having two diodes between them. And, the thermistor whose resistance varies significantly with temperature inversely and a operational amplifiers, so called as OP-amp, control the diodes in the compensations circuit to realize more effective thermal compendation characteristic compared with conventional circuit.

An Experimental Study on Flow Characteristics for Dual-Structured Orifice (이중구조 오리피스 팽창장치의 유동특성에 관한 실험적 연구)

  • 곽경민;김하덕;이중형;배철호;김종엽
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1039-1046
    • /
    • 2002
  • To investigate the characteristics of orifice as an expansion devices, the experimental apparatus was made and experiments are being peformed using R22 and R290. The main idea of this control method of refrigerant flow rate with coupled orifices is to control the ON/OFF state of T and Ball type orifice corresponding to the subdivided region of thermal load. When system requires minimum thermal load, both T and Ball type orifices are closed, but refrigerant can flow through small hole of T type orifice. In regular thermal load, when ball type orifice is closed, T type orifice is opened and mass flow rate increase more than OFF state of T type orifice, due to large diameter. In maximum thermal load, both T and Ball type orifices are open and the much refrigerant can flow. The flow characteristics on T type orifice and parallel-combined orifice are obtained in the subdivided region of thermal load.

Optimal Control of the Thermal Printhead with variable Division (가변분할을 통한 열전사헤드의 최적제어)

  • Yeom, H.J.;Jun, D.G.;Yoon, H.R.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.338-341
    • /
    • 1997
  • The current consumption and the heat produced in the printhead of thermal printer are mainly governed by total printing dots and printing time for each line. Simple algorithm is proposed to optimize the performance of a thermal printhead, which use variable division according to bit-mapped data of its 1 line. And, for protecting the thermal printhead from exceeding heat, I control the heat energy of each microheater(dots) on the thermal printhead through changes in the applied pulse width.

  • PDF

Numerical Investigation of On-orbit Thermal Characteristics for Cube Satellite with Permanent Magnet Attitude Stabilization Method (영구자석 안정화 자세제어 방식이 적용된 큐브위성의 열적 특성분석)

  • Kang, Soo-JIn;Jung, Hyun-Mo;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.3
    • /
    • pp.26-32
    • /
    • 2013
  • Passive attitude stabilization method has been widely usde for attitude determination and control of cube satellite due to its advantage of system simplicity. The permanent magnet installed on the cube satellite passively controls the attitude of the satellite such that the satellite is aligned with the earth magnetic field. In this paper, on-orbit thermal behavior of the cube satellite with the permanent magnet attitude stabilization method has been investigated through on-orbit thermal analysis. THe orbit profile obtained from the aforementioned attitude control method has been reflected in the analysis. The analysis results indicate that the thermal design proposed in this study is effective for satisfying the temperature requirements of the commericial mission equipments.