• Title/Summary/Keyword: Thermal Boundary Condition

Search Result 267, Processing Time 0.026 seconds

Automated Body-Fitted Grid Generation Method with Application to Natural Convection Problem (자동화된 경계고정좌표 생성법과 자연대류 문제에 대한 적용)

  • Choi, IL Kon;Maeng, Joo Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.703-712
    • /
    • 1999
  • This paper suggests an automatic elliptic grid generation method that is well-suited for the numerical mapping of complex geometries which are easily obtained from general CAD programs. An LBLADI solver is used for the governing mapping equations to have the strong diagonal dominance. The full boundary control method is adopted to determine the control functions of the equations, which allows the control of the grid regarding spacing and angle control at all boundary surfaces. The solution method presented here provides the capability of mapping very complicated geometries by defining grid point locations only along the boundaries. In the automated elliptic grid generation procedure, it is showed that strong diagonal dominance is essential to achieve successful mapping irrespective of the initial grid condition provided. To demonstrate the robustness of this method, it is applied to the thermal flow like the natural convection between eccentric cylinders. The results agree well with others.

Free Vibration Characteristics of Rectangular Plates under Uniform Thermal Loading Part II. Experimental Modal Test (균일 열부가 하중을 받는 사각판의 자유 진동특성 연구 Part II. 고유진동 실험)

  • Jeon, Byoung-Hee;Kang, Hui-Won;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.2
    • /
    • pp.106-113
    • /
    • 2011
  • This paper was conducted on experimental analysis in the free vibration analysis of rectangular plates under uniform thermal loading. Materials of three rectangular plates were aluminum, steel and stainless-steel respectively. The dimension of rectangular plates was 0.1 $\times$ 0.1 $\times$ 0.002 m. Infrared quartz lamps were used for thermal loading. The PCS(Power Control System) electric control system was applied for control and scanning vibrometer (Poly Tech) was used for acquisition of frequency response function. Applied temperature was increased from room temperature to $300^{\circ}C$ by $50^{\circ}C$. Boundary condition was free-free condition using bungee cord. Front face of rectangular plate was heated uniformly.

Thermal Deformation Induced Preload Changein the Tilting Pad Journal Bearing (열변형으로 인한 틸팅패드 저널베어링의 예압 변화)

  • Suh, Junho;Hwang, Cheolho
    • Tribology and Lubricants
    • /
    • v.32 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This paper focuses on the thermal deformation induced preload change in the tilting pad journal bearing, using a three-dimensional (3D) thermo-hydro-dynamic (THD) approach. Preload is considered as a critical factor in designing the tilting pad journal bearing. The initial preload measured under nil external load and nil thermal gradient is influenced by two factors, namely, the thermal deformation and elastic deformation. Thermal deformation is due to a temperature distribution in the bearing pads, whereas the elastic deformation is due to fluid forces acting on the pads. This study focuses on the changes induced in preload and film clearance due to thermal deformation. The generalized Reynolds equation is used to evaluate the force of the fluid and the 3D energy equation is used to calculate the temperature of the lubricant. The abovementioned equations are combined by establishing a relationship between viscosity and temperature. The heat transfer within the bearing pads, the lubricant, and the spinning journal is calculated using the heat flux boundary condition. The 3D Finite Element Method (FEM) is used in modeling the (1) heat conduction in the spinning journal and bearing pads, (2) thermal gradient induced thermal distortion of the spinning journal and pads, and (3) viscous shearing, and heat conduction and convection in a thin film. This evaluation method has an increased fidelity, and it can prove to be a cost-effective tool that can be used by designers to predict the dynamic behavior of a bearing.

Nonlinear bending of multilayer functionally graded graphene-reinforced skew microplates under mechanical and thermal loads using FSDT and MCST: A study in large deformation

  • J. Jenabi;A.R. Nezamabadi;M. Karami Khorramabadi
    • Structural Engineering and Mechanics
    • /
    • v.90 no.3
    • /
    • pp.219-232
    • /
    • 2024
  • In current study, for the first time, Nonlinear Bending of a skew microplate made of a laminated composite strengthened with graphene nanosheets is investigated. A mixture of mechanical and thermal stresses is applied to the plate, and the reaction is analyzed using the First Shear Deformation Theory (FSDT). Since different percentages of graphene sheets are included in the multilayer structure of the composite, the characteristics of the composite are functionally graded throughout its thickness. Halpin-Tsai models are used to characterize mechanical qualities, whereas Schapery models are used to characterize thermal properties. The microplate's non-linear strain is first calculated by calculating the plate shear deformation and using the Green-Lagrange tensor and von Karman assumptions. Then the elements of the Couple and Cauchy stress tensors using the Modified Coupled Stress Theory (MCST) are derived. Next, using the Hamilton Principle, the microplate's governing equations and associated boundary conditions are calculated. The nonlinear differential equations are linearized by utilizing auxiliary variables in the nonlinear solution by applying the Frechet approach. The linearized equations are rectified via an iterative loop to precisely solve the problem. For this, the Differential Quadrature Method (DQM) is utilized, and the outcomes are shown for the basic support boundary condition. To ascertain the maximum values of microplate deflection for a range of circumstances-such as skew angles, volume fractions, configurations, temperatures, and length scales-a parametric analysis is carried out. To shed light on how the microplate behaves in these various circumstances, the resulting results are analyzed.

Finite Element Analysis of Cylinder Head/Block Compound (엔진 실린더 헤드/블록의 유한 요소 해석)

  • Kim, Beom-Keun;Chang, Hoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.28-38
    • /
    • 2003
  • Finite element analysis of cylinder heat/block compound under assembly, thermal and firing condition were performed. FE model including two cylinders with gasket, head bolts, liners and valve seats was used. FE modeling method and boundary conditions were introduced. Stress distribution and deformation of cylinder head and block under each loading condition were presented. Gasket pressure distribution and bore distortion level were predicted. Measured data of bore distortion was compared with the analysis results. The analysis result showed similar trends with the experimental data. High cycle fatigue analysis on the basis of this result has been performed in order to find the critical areas of the engine assembly.

A Study on the Heat Transfer of Carbon Steels in Quenching (탄소강의 담금질 열전달에 관한 연구)

  • 김경근;윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.20-26
    • /
    • 1995
  • The very rapid cooling problem from $820^{\circ}$C to $20^{\circ}$C on the surface of the steel by thermal conduction including the latent heat of phase transformation of steel and by transient boiling heat transfer of water are considered to principal problem in quenching. The transient boiling process of water at the surface of specimen during the quenching process were experimentally analyzed. Then the heat flux was numerically calculated by the numerical method of inverse heat condition problem. In this report, the simulation program to calculate the cooling curves for large rolls was made using the subcooled transient boiling curve as a boundary condition. By this simulation program, the cooling curves of rolls from D=50mm to D=200mm were calculated and the effects of agitation of circulation of water also investigated.

  • PDF

Development of Numerical Model for Unsteady Flow Analysis jin Discharge Culvert of Thermal Power Plant: I. Model Setup (열발전소 배수암거 부정류해석 수치모형의 개발 : I. 모형의 정립)

  • Yun, Seong-Beom;Lee, Gi-Hyeok
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.761-768
    • /
    • 1997
  • A numerical model is developed to analyze the incompressible unsteady flow induced by the pump trip-out in the cooling water discharge culvert of thermal power plants. The numerical models has various features to deal concureently with the overall behavior of complicated unsteady flow due to the presence of cooling water internal system, seal well, air chamber, culvert, manholes, open channel and sea water. A leap-frog finite difference scheme is employed to solve governing equations, and the model is tested for a simple case of two tanks connected with a pipe. A fixed free surface boundary condition used earlier at the downstream end of culvert for large water body is investigated.

  • PDF

Thermal Effluent Diffusion and Flow Characteristics using the TGPS Buoy (TGPS 부이를 이용한 온배수 확산과 흐름 특성)

  • 박일흠;이연규;최정민
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.614-617
    • /
    • 2000
  • To get the maximum diffusion boundary of thermal effluent of Youngkwang Nuclear Power Plant, paths of TGPS Buoy and temperatures of surface water are obtained to 4 times at spring tide during 1 year. According to the paths of TGPS Buoy, the flumes of thermal effluent are moved about 12km from outlet to SW or WSW direction. After 3∼4 times of tidal period the waters are reached to Chilsan Island because the ebb flow is more predominant than the flood flow in this area. At the spring and fall season, a sudden drop of surface water temperature is detected around 5km radius from the outlet. At the summer season, it is measured about 10km. On the other hand the flumes are continuously cooled down by the atmosphere condition at winter season.

  • PDF

A Numerical Analysis to Predict the Temperature Distribution around a Cold Storage Cavern (지하암반 냉동저장고 주변의 온도분포 예측을 위한 수치해석)

  • 이규상;이정인
    • Tunnel and Underground Space
    • /
    • v.14 no.4
    • /
    • pp.287-294
    • /
    • 2004
  • To predict the temperature distribution around a underground rock storage cavern, two- and three- dimensional numerical analysis using FLAC was conducted. The effects of groundwater and latent heat on thermal properties were considered in numerical calculation. The temperature estimated by FLAC are compared with the temperature measured for 5-year operation at Gonjiam storage cavern. Estimated and measured temperatures showed great discrepancy when thermal properties from laboratory tests were used and showed good agreement when the effects from 20% of volumetric water fraction and latent heat were considered. However, the discrepancy still increased with operation time due to the heat flow from ground surface. Three-dimensional numerical models were established to closely approximate the boundary condition of the test site, and numerical results better agreement when groundwater and latent heat effects were considered.

2D Heat Transfer Model for the Prediction of Temperature of Slab in a Direct-Fired Reheating Furnace (가열로 내 슬랩의 온도 예측을 위한 2차원 열전달 모델)

  • Lee Dong-Eun;Park Hae-Doo;Kim Man-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.10 s.253
    • /
    • pp.950-956
    • /
    • 2006
  • A mathematical heat transfer model for the prediction of heat flux on the slab surface and temperature distribution in the slab has been developed by considering the thermal radiation in the furnace and transient conduction governing equations in the slab, respectively. The furnace is modeled as radiating medium with spatially varying temperature and constant absorption coefficient. The slab is moved with constant speed through non-firing, charging, preheating, heating, and soaking zones in the furnace. Radiative heat flux which is calculated from the radiative heat exchange within the furnace modeled using the FVM by considering the effect of furnace wall, slab, and combustion gases is applied as the boundary condition of the transient conduction equation of the slab. Heat transfer characteristics and temperature behavior of the slab is investigated by changing such parameters as absorption coefficient and emissivity of the slab. Comparison with the experimental work shows that the present heat transfer model works well for the prediction of thermal behavior of the slab in the reheating furnace.