• Title/Summary/Keyword: Theodolite

Search Result 47, Processing Time 0.029 seconds

A Study on Measurement Accuracy of A Theodolite System(V) - A Measurement System Accuracy depending on the distance from theodolite system to target Bars (데오드라이트 시스템의 측정 정확도에 대한 연구(V) - 타켓 바의 거리에 따른 측정 정확도)

  • Yoon Yong-Sik;Lee Dong-Ju
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.13-21
    • /
    • 2005
  • The affected factors for an accuracy of theodolite system are not only the measurement environment of temperature, illumination, etc. but also the measurement processes of the distance between two theodolites, the distance from theodolite system to scale bar and the distance from theodolite system to targets. We have known that the best collimation distance between two theodolites and the best distance from theodolite system to scale bar is $3{\sim}4m$. This study was performed for searching the best distance from theodolite system to targets on above measurement configuration. And, we could know that the best distance from theodolite system to targets is $2{\sim}6m$ and the system accuracy could be within ${\pm}0.025mm$.

A Study on Measurement Accuracy of Theodolite System(III) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 3 m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(III) - 시준거리 3 m에서 기준자 거리에 따른 측정 정도)

  • Yoon Yong Sik;Lee Dong Ju;Yoon In Jin
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.2
    • /
    • pp.48-54
    • /
    • 2005
  • The theodolite system consists of two theodolites, a scale bar and a target bu. A measurement accuracy of theodolite system is affected by a measurement distance of each equipment. This study was performed fir measuring an accuracy when the distance from theodolite to scale bar was changed 2~ 6 m on two theodolites distance 3 a The results showed thai the measurement accuracy could be $\pm$0.021 mm when the distance from theodolite to target was 2,3 and 6 n Specially, it was found that the maximum measurement accuracy was 10.017mm on theodolite collimation distance 3m and the distance 4 m of the theodolite and scale bar.

A Study on Measurement Accuracy of Theodolite System( I ) - A Measurement Accuracy According to a Theodolite Collimations Distance (데오도라이트 시스템의 측정 정확도에 대한 연구( I ) - 데오도라이트 시준 거리에 따른 측정 정확도)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • A non-contact precision measurement system is a theodolite system, a laser tacker and a photogrammetry system etc. Nowadays, the system reaches to a limit of measurement accuracy required from industrial product of middle and large scale. The one of the solutions for this problem is to maximize the accuracy of the existing measurement system. According to it we performed the study far a measurement accuracy of theodolite system when the distance between two theodolites is changed 1m to 5m. We could blow that the changes of distance affect the measurement accuracy of theodolite system and that the maximum measurement accuracy is $\pm$ 0.02 mm on theodolite distance 3∼4 m.

A Study on Measurement System Accuracy of Theodolite System(IV) - A Measurement System Accuracy depending on a Distance of Scale Bar on the Distance 4m between two Theodolites (데오드라이트 시스템의 측정 정확도에 대한 연구(IV) - 시준거리 4m에서의 기준자 거리에 따른 측정 정도)

  • Yoon Yong-Sik;Lee Dong-Ju;Park Yo-Chang
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.67-73
    • /
    • 2005
  • An accuracy of theodolite system may be affected by a measurement environment and a measurement distance change from theodolite to scale bar and/or targets. This study was performed for measuring an accuracy when the distance from thodolite system to scale bar was changed $2\~6m$ on the distance 4m between two theodolites. The results showed that an accuracy was ${\pm}0.025mm$ or better when the distance from theodolite system to targets was 3, 4 and 5m. According to the results, it was found that the best distance from theodolite system to scale bar was $3\~4m$ when the collimation distance was $3\~4m$.

Study on Measurement Accuracy by Auto-Collimation using Theodolite (데오드라이트를 이용한 자동 시준에 의한 측정 정확도에 관한 연구)

  • Lee Byoung-Gi;Kwon Jae-Wook;Yoon Yong-Sik
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1793-1796
    • /
    • 2005
  • The auto-collimation by using theodolite has been accomplished for the straight measurement and the horizontality adjustment. But according to the procedure of auto-collimation or composition of the measurement equipment, an error of the measurement can be occurred. Therefore, this paper accomplished the research for enhancement of measurement accuracy according to measurement procedure of auto-collimation. For that, it has been compared the study of the combination of several precise measurement equipment with using of several theodolite.

  • PDF

A Study on Measurement Accuracy of Theodolite System(II) -A Measurement Accuracy for a Height of Scale Bar (데오드라이트 시스템의 측정 정확도에 대한 연구(II) -기준자 측정 높이에 따른 측정 정확도)

  • 윤용식;이동주;정종길
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.37-43
    • /
    • 2004
  • A measurement accuracy of theodolite system may be affected by a measurement environment, a measurement distance change and so on. This study was performed for measuring an accuracy when the height of scale bar is changed 0.05m, 0.5m, 1m and 1.5m under the distance 3m between two theodolites, the distance 4m from the theodolite system to scale bar and the distance 5m from the thodolite system to the horizontal target bar. And we could know that the best height is 0.05m and 1m.

Range Alignment Measurement for Satellite Antenna by Using Theodolite System (데오드라이트 시스템을 이용한 위성 안테나 레인지 얼라인먼트 측정)

  • Park, Hong-Cheol;Son, Yeong-Seon;Yun, Yong-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.134-141
    • /
    • 2004
  • The three-dimensional precision measurement technology for industrial product of middle and/or large scale has been developed. Theodolite measurement system which is one of the technology is widely used in aerospace industry. This paper describes a range alignment method of parabolic antenna to RF probe in the near field range by using the theodolite system, The range alignments of the Ku-band and Ka-band antennas have been accomplished within the requirements, ${\pm}1mm\;and\;{\pm}0.05^{\circ}$.

SURFACE FIGURE OF 14M RADIO TELESCOPE MEASURED BY THEODOLITE (THEODOLITE로 측정한 14 m 전파망원경의 주경면 모양)

  • Jung, Jae-Hoon;Kim, Hyun-Goo;Kim, Tai-Seong;Chung, Hyun-Soo;Park, Yong-Sun
    • Publications of The Korean Astronomical Society
    • /
    • v.12 no.1
    • /
    • pp.159-165
    • /
    • 1997
  • In order to reduce the small scale fluctuation resulting from shearing holograpy(Park et. al. 1997), differential panel adjustments were performed for 14 m radio telescope of Taeduk Radio Astronomy Observatory with T2 theodolite It appears that this method improves the surface accuracy by about $50\;{\mu}m$. The measured surface accuracy is, at best, $170\;{\mu}m$. The beam efficiency at 86.2 GHz is estimated to be 44% We also found that the elevation at which Park et. al. performed holography was too low.

  • PDF

A Study on Spacecraft Alignment Measurement with Theodolite (데오도라이트를 이용한 위성체 얼라인먼트 측정에 관한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.64-70
    • /
    • 2003
  • A measurement of spacecraft alignment is an important process of spacecraft assembly, integration and test because it is necessary that a ground station controls the precise positions of on-orbit spacecraft by using the alignment data of attitude orbit control sensors(AOCS) on spacecraft. In addition, accuracy of spacecraft alignment requirement is about $0.1^{\circ}$~$0.7^{\circ}$. The spacecraft alignment is measured by autocollimation of theodolite. This paper describes the measurement principle and method of spacecraft alignment. The result shows that all of the AOCS on the spacecraft are aligned within the tolerance required through the alignment measurement.

A Study on Measurement Error Factors of Theodolite System (데오도라이트 시스템의 측정 오차 요인에 대한 연구)

  • 윤용식;이동주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.4
    • /
    • pp.36-42
    • /
    • 2003
  • Theodolite measurement system is non-contacted 3-dimensional measurement system. The system accuracy is ${\pm}0.5mm$or better for distance 0~100m. And the system is used for the measurement of a product of middle and large scale. This study is performed for the measurement error factors of the system. We could know that the main measurement error factors are temperature, illumination and skill. Also, we performed the study for the effect according to the height difference of scale bar.