• 제목/요약/키워드: The surface hardness

검색결과 2,499건 처리시간 0.029초

발효음식이 의치상레진의 색상 및 표면경도 변화에 미치는 영향 (THE EFFECT OF FERMENTED FOODS ON THE COLOR AND HARDNESS CHANGE OF DENTURE BASE ACRYLIC RESINS)

  • 전열매;임헌송;신수연
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.344-355
    • /
    • 2004
  • Statement of problem: For a long time, many of denture base acrylic resins have been used for edentulous and partial edentulous patients because of easy manipulation and good mechanical properties, but its esthetic aspect has not been commented enough. Denture base acrylic resins also has caused esthetic problems due to discoloration or staining as in esthetic restoration. Many researches and reports have treated the problems and accomplished esthetic improvement. But these researches and reports dealt with general food colors or beverages, not with fermented foods. Purpose: This study is designed to assess what fermented foods, such as soy sauce, gochujang, and toenjang that many of Koreans have taken in, influence on the color and hardness variation of denture base acrylic resins. Materials and methods: For the procedure, twelve disks per 4 denture base acrylic resins were fabricated with a thickness of 2mm and 16mm in diameter. Each seven specimen were measured for discoloration with spectrophotometer, while the others, five specimen, for surface hardness change with Barcol hardness tester, over time. Each 12 specimen were immersed into the 4 beakers of fermented foods(soy sauces, gochujangs, toenjangs, deionized water), and $L^{*},a^{*}$, and $b^*$ values were measured for the color difference$({\Delta}E^*)$, on the 1st, 7th, and 28th day with spectrophotometer, with the measurement of surface hardness change. Each data observed was processed statistically. Results: The findings are as follows; Discoloration 1. All of denture base resins was not influenced by the kind of fermented foods, except for $QC20^{(R)}$ 2. Soy sauce and red pepper paste caused more change for denture base resins than deionized water and soy bean paste, except for Perform$^{(R)}$ 3. Most significant change was shown in Lucitone 199$^{(R)}$, whereas Perform$^{(R)}$ results in the least change for all immersed solution, with no statistical significance. Hardness change 1. Barcol hardness values in deposited specimens have been changed low degree, but with significant statistical change according to the kind of food and duration. 2. Lucitone$^{(R)}$ 199 as significantly lower Barcol hardness value than others do. Conclusion: Based on the above results, it suggests that the habitual intake of fermented foods is not helpful for the color stability of denture base acrylic resins because Soy sauce and red pepper paste mainly caused discoloration and surface hardness change. Particularly $Lucitone199^{(R)}$ shows specific discoloration and low surface hardness values. Therefore, it is recommended giving caution patients with denture of $Lucitone199^{(R)}$ especially against the habitual intake of fermented foods like soy sauce and red pepper paste.

Tissue Conditioner가 수종의 의치상용 레진의 물리적 성질에 미치는 영향 (THE PHYSICAL EFFECT OF TISSUE CONDITIONER ON POLYMERIZED ACRYLIC RESINS)

  • 강동주;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제35권1호
    • /
    • pp.1-14
    • /
    • 1997
  • The purpose of this study was to investigate the physical effect of tissue conditioner on polymerized acrylic resins. Surface hardness and transverse strength were measured for evaluating physical effect of tissue conditioner on polymerized acrylic resins. 1) To measured surface hardness, the resin specimens($65{\times}10{\times}10mm$ size) of each resin material were made, applied tissue conditioner, stored in $37^{\circ}C$ water for 1 week, and changed tissue conditioner every week for 3 weeks. Surface hardness was measured every week with Shore hardness tester for 4 weeks. 2) To measured transverse strength, the resin specimens($65{\times}10{\times}3mm$ size & $65{\times}10{\times}1.5mm$) of each resin material were made. The specimens were divided into four groups, and measured by universial testing machine. Group I(control group) : The resin specimens were stored in $37^{\circ}C$ water for 5 weeks. Group II : The resin specimens were stored in $37^{\circ}C$ water for 5 weeks, and relined in 1.5mm thickness with same resin. Group III : The resin specimens were stored in $37^{\circ}C$ water for 1 week, applied tissue conditioner in 1.5mm thickness, stored in $37^{\circ}C$ water for 1 week, changed tissue conditioner and water every week for 3 weeks, removed tissue conditioner, reduced 1.5mm thickness from resin surface which was applied tissue conditioner, and relined in 1.5mm thickness with same resin. The following conclusions were obtained : 1. Surface hardness changes of Vertex RS and Vertex SC were not different significantly(p>0.01). 2. Surface hardness of K-33, Tokuso rebase, and Kooliner were decreased(p<0.01). 3. With the exception of Kooliner, transverse strength of all resin materials between control group and groups which applied with tissue conditioner were not different significantly(p>0.01).

  • PDF

유한요소해석에 의한 코팅면의 브리넬 경도 평가: 제1보 - 타당성 연구 (Evaluation of Brinell Hardness of Coated Surface Using Finite Element Analysis: Part 1 - A Feasibility Study)

  • 박태조;강정국
    • Tribology and Lubricants
    • /
    • 제36권6호
    • /
    • pp.378-384
    • /
    • 2020
  • The friction surfaces of mechanical parts are heat-treated or coated with hard materials to minimize wear. Increasing the hardness is a very useful way to reduce abrasive wear. The general Brinell hardness test, which is widely used for metallic materials, is not suitable because it hardly shows any change in hardness when coated with thin films. In this study, we propose a basis for the application of the new Brinell hardness test method to the coated friction surface. An indentation analysis of the rigid sphere and elastic-perfectly plastic materials is performed using a commercial finite element analysis software. The results indicate that their loadto-diameter ratio is the same; the Brinell hardness test method can be applied even when the indenter diameter is on the micrometer scale. In the case of hard coating, it is difficult to calculate Brinell hardness using the diameter of the indentation, but the study revealed, for the first time, that it can be calculated using the depth of the indentation regardless of coating. The change in hardness owing to thin film coating over a wide load range implies that the hardness evaluation method is appropriate. Additional studies on various properties related to the substrate and coating material are required to apply the proposed method.

Effect of denture cleansers on surface hardness of resilient denture liners at various time intervals- an in vitro study

  • Pahuja, Rasleen Kaur;Garg, Sandeep;Bansal, Sanjay;Dang, Rajat Harvinder
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.270-277
    • /
    • 2013
  • PURPOSE. This study was aimed to determine the effect of two chemically distinct denture cleansers and water on the surface hardness of acrylic and silicone based soft denture liners at various time intervals. MATERIALS AND METHODS. Two commonly used commercial resilient liner material were selected based on their chemical composition (silicone- and acrylic-based soft liners) for this investigation. 120 cylindrical specimens were made of $15mm{\times}10mm$ dimensions (according to ASTM: D-2240-64T) in a custom made metal mold. All specimens were stored in artificial saliva throughout the study. Forty specimens were cleansed daily in 0.5% sodium hypochlorite solution; forty were cleansed in sodium perborate and remaining forty specimens were daily rinsed in water. Testing was done at 1 week, 1 month, 3 months and 6 months for surface hardness using a Shore A Durometer. A mean of 3 reading for each sample was subjected to one-way ANOVA, Post Hoc test and pair-t test for statistical analysis. P values of less than 0.05 were taken as statistically significant. RESULTS. Surface hardness of all the samples was significantly higher after a period of 6 months irrespective of the cleansing treatment. Minor changes were observed between control, sodium hypochlorite and sodium perborate groups with time. Greater change was observed in surface hardness of acrylic-based soft denture liners as compared to silicone-based soft liners for all groups, as time progressed. CONCLUSION. Silicone-based soft denture liners performed significantly better in all cleansing treatments than acrylic-based soft denture liners.

평면 Rolling에 의한 표면특성 변화에 관한 연구(l) (A Study on the Change of Suface Characteristics by plane suface Rolling(l))

  • 김희남
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1997년도 춘계학술대회 논문집
    • /
    • pp.1-5
    • /
    • 1997
  • The plane surface rolling, one of the plastic working process, good surface condition due to increase of surface roughness and hardness. It is well known that mechanism of surface rolling depends upon rolling conditions such as rolling speed, contact pressure, step length of rolling, the shape of roller and mechanical properties of material. In this study, the optimal value of the above parameter on the surface roughness were investigated by using the rolling tool with NACHI 6000ZZ ball bearing outer races on machine structure carbon steel[SM45C]

  • PDF

DC 및 RF 스퍼터링법으로 증착한 Cr 박막의 특성 비교 (A Comparison of the Properties of DC and RF Sputter - deposited Cr films)

  • 박민우;이종무
    • 한국재료학회지
    • /
    • 제16권8호
    • /
    • pp.461-465
    • /
    • 2006
  • Chromium (Cr) films were deposited on plain carbon steel sheets by DC and RF magnetron sputtering as well as by electroplating. Effects of DC or RF sputtering power on the deposition rate and properties such as, hardness, surface roughness and corrosion-resistance of the Cr films were investigated. X-ray diffraction (XRD), atomic force microscopy (AFM), scanning electron microcopy (SEM) analyses were performed to investigate the crystal structure, surface roughness, thickness of the Cr films. Salt fog tests were used to evaluate the corrosion resistance of the samples. The deposition rate, hardness, and surface roughness of the Cr film deposited by either DC or RF sputtering increase with the increase of sputtering power but the adhesion strength is nearly independent of the sputtering power. The deposition rate, hardness, and adhesion strength of the Cr film deposited by DC sputtering are higher than those of the Cr film deposited by RF sputtering, but RF sputtering offers smoother surface and higher corrosion-resistance. The sputter-deposited Cr film is harder and has a smoother surface than the electroplated one. The sputter-deposited Cr film also has higher corrosion-resistance than the electroplated one, which may be attributed to the smoother surface of the sputter-deposited film.

다이오드 레이저를 이용한 금속 표면 열처리 특성 (Characteristics of Metal Surface Heat Treatment by Diode Laser)

  • 최성대;정선환;김기만;양승철;김잠규
    • 한국기계가공학회지
    • /
    • 제6권3호
    • /
    • pp.16-23
    • /
    • 2007
  • An experimental investigation with diode laser system was carried out to study the effect of surface heat treatment on the die materials(SM45C, SKD11, SK3). The surface heat treatment characteristics of the laser beam are evaluated using hardness tests, optical microscopy, X-ray diffraction and energy dispersive X-ray spectroscopy(EDS). Results indicated that the beam size, focal length, feed rates are changed surface hardened characteristics. SM45C is higher hardness than other materials and composed to martensite grain at hardened zone, whereas other materials(SKD11, SK3)are low hardness than expected and composed to austenite and allayed martensite at hardened zone. The intensive X-ray diffraction patterns of (110)-(200)-(211) is detected hardened surface and the hardened surface distributed plenty of carbon density than metal zone.

  • PDF

UNSM 기술을 이용한 초경의 기계적 특성변화 (Changes in Mechanical Properties of WC-Co by Ultrasonic Nanocrystal Surface Modification Technique)

  • 이승철;김준형;김학두;최갑수;아마노프 아웨즈한;편영식
    • Tribology and Lubricants
    • /
    • 제31권4호
    • /
    • pp.157-162
    • /
    • 2015
  • In this study, an ultrasonic nanocrystalline surface modification (UNSM) technique is applied to tungsten carbide-cobalt (WC-Co) to extend the service life of carbide parts used in press mold. The UNSM technique modifies the structure, reduces the surface roughness, increases the surface hardness, induces the compressive residual stress, and increases the wear resistance of materials by introducing severe plastic deformation. The surface roughness, hardness, and compressive residual stress of WC after UNSM treatment improve by about 42, 10, and 71%, respectively. A wear test under dry conditions is used to assess the effectiveness of the UNSM technique on the friction and wear behavior of WC. The UNSM technique is found to reduce the WC friction coefficient by approximately 21% and enhance the wear resistance by approximately 85%. The improved friction and wear behavior of WC may be mainly attributed to the increased hardness and compressive residual stress. Moreover, the WC specimen is treated by UNSM technique using three different WC, silicon nitride (Si3N4) and stainless steel (STS304) balls. The surface treated by WC balls shows the highest hardness when compared with treatment by stainless steel and silicon nitride balls. According to the obtained results, the UNSM technique is believed to increase the durability of the carbide component by improving the friction and wear behavior.

Effects of Bilayer Period on the Microhardness and Its Strengthening Mechanism of CrN/AlN Superlattice Coatings

  • Kim, SungMin;Kim, EunYoung;Kim, DongJun;La, JoungHyun;Lee, SangYul
    • 한국표면공학회지
    • /
    • 제45권6호
    • /
    • pp.257-263
    • /
    • 2012
  • CrN/AlN multilayer coatings with various bilayer periods in the range of 1.8 to 7.4 nm were synthesized using a closed-field unbalanced magnetron sputtering method. Their crystalline structure, chemical compositions and mechanical properties have been investigated with Auger electron spectroscopy, X-ray diffractometry, atomic force microscopy, nanoindentation, scratch tests. The properties of the multilayer coatings varied strongly depending upon the magnitude of the bilayer period. The multilayer coating with a bilayer period of 1.8 nm showed the maximum hardness and an elastic modulus of approximately 37.6 and 417 GPa, respectively, which was 1.54 times higher than the hardness predicted by the rule of mixture from the CrN and AlN coatings. The hardness of the multilayer coating increased as the bilayer period decreased, i.e. as the rotation speed increased. The Hall-Petch type relationship, hardness being related to (1/periodicity)$^{-1/2}$, suggested by Lehoczky was confirmed for the CrN/AlN multilayer coatings with bilayer period close to the 5-10 nm range. With decreasing bilayer period, the surface morphology of the films became rougher and the critical load of films for adhesion strength gradually decreased.

The Effects of Gas Compositions During Post Nitriding on the AISI 316L Stainless Steel after Plasma Carburizing

  • Lee, Insup
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.269-274
    • /
    • 2015
  • In this experiment, post-nitriding treatment was performed at $400^{\circ}C$ on AISI 316 stainless steel which was plasma carburized previously at $430^{\circ}C$ for 15 hours. Plasma nitriding was implemented on AISI 316 stainless steel at various gas compositions (25% $N_2$, 50% $N_2$ and 75% $N_2$) for 4 hours. Additionally, during post nitriding Ar gas was used with $H_2$ and $N_2$ to observe the improvement of surface properties. After treatment, the behavior of the hybrid layer was investigated by optical microscopy, X-ray diffraction, and micro-hardness testing. Potentiodynamic polarization test was also used to evaluate the corrosion resistance of the samples. Meanwhile, it was found that the surface hardness increased with increasing the nitrogen gas content. Also small percentage of Ar gas was introduced in the post nitriding process which improved the hardness of the hardened layer but reduced the corrosion resistance compared with the carburized sample. The experiment revealed that AISI 316L stainless steel showed better hardness and excellent corrosion resistance compared with the carburized sample, when 75% $N_2$ gas was used during the post nitriding treatment. Also addition of Ar gas during post nitriding treatment degraded the corrosion resistance of the sample compared with the carburized sample.