• Title/Summary/Keyword: The size of human body

Search Result 490, Processing Time 0.029 seconds

A Study on the Hermetic Method for Packaging of Implantable Medical Device (생체 이식형 의료기기의 패키징을 위한 완전 밀폐 방법에 관한 연구)

  • Park, Jae-Soon;Kim, Sung-Il;Kim, Eung-Bo;Kang, Young-Hwan;Cho, Sung-Hwan;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.7
    • /
    • pp.407-412
    • /
    • 2017
  • This paper introduces a biocompatible packaging system for implantable medical device having a hermetic sealing, such that a perfect physical and chemical isolation between electronic medical system and human body (including tissue, body fluids, etc.) is obtained. The hermetic packaging includes an electronic MEMS pressure sensor, power charging system, and bluetooth communication system to wirelessly measure variation of capacitance. The packaging was acquired by Quartz direct bonding and $CO_2$ laser welding, with a size of width $ 6cm{\times}length\;10cm{\times}lheight\;3cm$. Hermetic sealing of the packaged system was tested by changing the pressure in a hermetic chamber using a precision pressure controller, from atmospheric to 900 mmHg. We found that the packaged system retained the same count or capacitance values with sensor 1 - 25,500, sensor 2 - 26,000, and sensor 3 - 20,800, at atmospheric as well as 900 mmHg pressure for 5 hours. This result shows that the packaging method has perfect hermetic sealing in any environment of the human body pressure.

A study of Developing Torso Master Pattern Using 3D body Measurement Data - Focusing on Women in their thirties proper Body Types - (3차원 인체형상자료를 활용한 토르소 마스터패턴 개발 - 30대 바른 체형 여성을 대상으로 -)

  • Shin, Ju-Young Annie;Nam, Yun-Ja
    • Fashion & Textile Research Journal
    • /
    • v.17 no.3
    • /
    • pp.447-461
    • /
    • 2015
  • The purpose of this study is to develop a torso pattern that is highly representative for the proper body shape of women in their thirties. Size data of the women with age of 30 through 39 from the database of Size Korea 2004 were used for the study. In order to develop a master pattern which will be used as the benchmark for grading of research group, 4 existing torso block drafting methods were compared based on the data gathered and the block with the highest evaluation score was utilized as a reference point. For the analysis, data was divided into four types, only the data of 138 subjects which were evaluated at least by four or more experts as valid were used for the study. The major results can be summarized as follow. The women of bust girth of 91cm and height of 160cm which was turned out to be representative type of research group were used as standard measurement for the purpose of reflecting not only curve length of the 3D analysis measurement but also the difference between front and back thickness to the pattern. Dart locations were set based on front and back torso ease, shoulder area revisions, front sagging length 1.5cm and cross section crevice length analysis. According to the experts' appearance evaluation of the pattern was found to be better than the control pattern which was regarded as the best among 4 patterns created based on existing torso block drafting methods.

Fundamental research for the development of personal protective equipment for emergency medical technicians (구급대원용 개인보호복 개발을 위한 기초연구)

  • No, Yoo-Min;Nam, Yun-Ja;Lee, Hye-Rin;Kim, Tae-Han;Kim, Chu-Hyun;Shin, Sang-Do
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.83-97
    • /
    • 2018
  • Purpose: The purpose of this study was to provide basic data for the development of personal protective equipment (PPE) for emergency medical technicians (EMTs) during chemical, biological, radiological, nuclear, and explosive situations. Methods: Body measurements were obtained for adults aged from 20 to 59 years from the data in the 6 th Size Korea national sizing survey. These data were compared to the sizes of protective clothing currently available in the market. In-depth interviews with active paramedics with experiences of wearing PPE were conducted. Results: Most of the imported protective clothing turned out to be unfit for Korean adults. This showed the urgent need for developing appropriately sized protective clothing for Korean emergency technicians. In total, 55.0% of the respondents indicated that the current protective clothing is unsafe, and 71.0% requested the clothing to have level C protective performance. Regarding the design, many people wanted hooded all-in-one type of clothing. Conclusion: Considering these requirements, most of the wearers wanted their protective clothing to be fundamentally protective of their body, be available in various sizes with adjustable parts, and easy to wear and take off. They also wanted the clothing to be secure in clear sight, while not revealing any parts of their body and not interfringe with their ability to communicate with others.

Changes in Brain Activity of Rats due to Exposure to Fine Dust Using 18F-FDG PET (18F-FDG PET를 이용한 미세먼지 노출에 따른 쥐(rat)의 뇌 활성도 변화)

  • Cho, Yun-Ho;Cho, Kyu-Sang;Lee, Wang-Hui;Choi, Jea-Ho
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.225-232
    • /
    • 2022
  • Fine dust threatens human health in various forms, depending on the particle size, such as by causing respiratory, cardiovascular, and brain diseases, after entering the body via the lungs. The aim of this study was to correlate fine dust exposure with changes in brain blood flow in Sprague Dawley rats by using micro-positron emission tomography and elucidate the possibility of developing cerebrovascular diseases caused by fine dust. The subjects were exposured to an average fine dust (particulate matter 2.5) of 206.2 ± 7.74 to ten rats four times a day, twice a day for 90 min. Before the experiment, they were maintained at NPO to the maximize the intake of 18F-fluorodeoxy glucose(18F-FDG) and minimize changes in the 18F-FDG biomass depending on the ambient environment and body temperature of the rats. PET images were acquired in the list mode 40 min after injecting 18F-FDG 44.4 MBq into the rats tail vein using a micro-PET scanner pre and post exposure to fine dust. We found that the whole brain level of 18F-FDG standardized uptake value in rats averaged 5.21 ± 0.52 g/mL pre and 4.22 ± 0.48 g/mL post exposure to fine dust, resulting in a statistically significant difference. Fine dust was able to alter brain activity after entering the body via the lungs in various forms depending on the particle size.

Preliminary Results of Thermal Effects due to Mobile Phones

  • Sik, Yoo-Done
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.471-473
    • /
    • 2002
  • Public concerns associated with the electromagnetic field (EMF) exposures from mobile phones on human body are increased. Although studies on the effects of the EMF exposures on human have been carried out for a long time, it is not proved yet whether the EMF effect is harmful or not. Based on the scientific results by experts, EMF exposure limits have been regulated as a precautionary approach on the assumption that the EMF effect may be harmful. It is well known that absorbed EMF can be transformed into heat within biological tissues and that thermal effects are related with the specific absorption rate (SAR) distribution. However, the relative magnitude and distribution of the energies are not well defined. Although there is comprehensive information of the thermal effects, most of them come from animal and in vitro studies. Considerable efforts have been made to analyze the EMF absorption model while the actual temperature in the human body has been rarely measured. Temperature changes on the face of a healthy male volunteer were studied. A digital mobile phone of 1.8GHz was used. A digital infrared imaging system (IRIS-5000, Medicore, Seoul, Korea) was applied to take infrared pictures of the face every minute while the volunteer talked over the mobile phone for 20 minutes. The specification of the imaging system was as follows: Temperature resolution = 0.1$^{\circ}C$; Range of temperature measurement = 17~40$^{\circ}C$; Pixel size = 0.9mm ${\times}$ 0.9mm; Frame time = 2.6s; Active temperature of detector = 77$^{\circ}$K. The result showed that temperature of the ear region was increased during the phone call and the region of the temperature increase on the face was expanded as the phone call time increased. Further study is necessary to investigate the temperature rise analytically and quantitatively.

  • PDF

Gamma-ray Dose Measurements in a Human Phantom Using Thermoluminescent Dosimeter

  • Yoo, Young-Soo;Lee, Hyun-Duk
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.239-247
    • /
    • 1974
  • A human phantom of polyethylene has been designed and sculptured for studying the effective radiation safety control. The phantom has the approximate size of the Korean adult and was sliced into thirty-five transverse slabs, 2.5 cm thick, The relative dose at the specified position was determined from the exposure that a TLD badge worn on the surface of the phantom body received from external ${\gamma}$-ray. The variation of the exposure as a function of depth in the phantom was measured for uncollimated ${\gamma}$-ray using TLD rods, and also isodose curves were obtained for the anatomical cross-section of the critical organs of the body. To simulate radiation exposure condition in the nuclear facility, measurements were made for given angles of incident ${\gamma}$-ray. The front to back attenuation factor for human phantom of thickness 20 cm was 0.439 for Cs$^{137}$ ${\gamma}$-ray which is in reasonable agreement with the published data.

  • PDF

The Development of Torso & Sleeve Basic Pattern for Wedding Dress (웨딩드레스를 위한 토르소 및 소매 원형 개발)

  • Hong, Geun-Hye;Jang, Jeong-Ah
    • Fashion & Textile Research Journal
    • /
    • v.13 no.4
    • /
    • pp.614-623
    • /
    • 2011
  • The purpose of this study is to develop a wedding dress basic torso pattern and sleeve pattern considering good fit and aesthetic for figures of Korean brides in their 20s. For the research method, 3 women in their 20s who has the body size of ${\pm}$ S.D range of average figure and dress form suggested by 'the 5th human body measurement' of Size Korea were selected as the test group. The evaluators are 8 clothing construction majors, and the evaluation items included total 22 questions related to torso and total 10 questions related to sleeves. The evaluation was made using 5 Likert point scale. 4 prototypes for basic dress pattern were selected through the literature search. After compare analyzing design methods of prototypes, the real wedding dresses were made in the average size of women in their 20s and the dresses were tried on for the assessment. The data was analyzed using SPSS 18.0 Program to examine average, standard deviation and significant differences between basic patterns. Based on the results of the first and the second try-on assessments, a new wedding dress basic pattern with maximized strengths of compared prototypes was completed. The details of result follows. As for dress torso basic pattern, A pattern, which had the highest overall silhouette satisfaction and scores in basic pattern analysis and try-on assessments, was selected as the prototype, and a research basic pattern reflecting strengths of each basic pattern was developed. As for dress sleeve basic pattern, B pattern, which had the highest overall silhouette satisfaction and scores in basic pattern analysis and try-on assessments, was selected as the prototype, and a research basic pattern reflecting strengths of each basic pattern was developed. In this study, a wedding dress basic pattern considering good fit and aesthetic for figures of Korean brides in their 20s was suggested. It is expected that the basic pattern will be used by continuously developing dress market and ready-made wedding dress manufacturers as well as in educational institutes.

A Study on the Analysis of the Torso and Breast of Female Students by Age (13-18세 여학생의 상반신과 젖가슴형태 연령별 분석연구)

  • Kim, Youn Joo;Nam, Yun Ja
    • Human Ecology Research
    • /
    • v.57 no.2
    • /
    • pp.159-170
    • /
    • 2019
  • The growth accelerator period from a child's body into an adult body is a huge transition characterized by rapid growth in the near term. Body shape changes at this time of growth should be continually studied because they can result in different outcomes due to various variables. This study is basic study for the production of a junior brassiere patternmaking was conducted to separate the upper torso and breasts of adolescents by growth level. Analysis was conducted by age classification according to sales trends. In this study. 3D body shape data of Korean girls, Based on the 6th Size Korea data, analyzed statistically the upper body and breast according to the rate of growth. The results of this study represent the basis for the development of a junior brassiere to help lead a better life in regards to clothing. The study used 3D-data from girls aged 13 to 18. The analysis indicates that the upper body is in a different shape at age 15 with an increasing circumference, width and shoulder length of the chest; in addition, the sides are analyzed differently, suggesting that the brassiere configuration should be made differently at age 15. The breast form also showed different growth patterns at age 13 and the result was that the shape of the cup in brassiere should be configured differently depending on type.

Development and Application of an Anthropometric Design Method Considering Physical Human Variabilities (신체적 다양성을 고려한 인체측정학적 설계 방법 개발 및 적용)

  • Jung, Ki-Hyo;Lee, Baek-Hee;You, Hee-Cheon
    • IE interfaces
    • /
    • v.24 no.4
    • /
    • pp.420-427
    • /
    • 2011
  • The present study developed an anthropometric design method accommodating physical human variabilities for user-centered product development. The proposed design method is based on the boundary zone method, a technique to generate a group of humanoids properly representing the body size diversity of thedesign target population. In addition, the anthropometric design method considers the variability of postures in the design process by incorporating the simulation of posture. The effectiveness of the proposed design method was evaluated in terms of multivariate accommodation percentage (MAP) by applying it to designing a computer workstation with 90% of accommodation percentage. The performance evaluation showed that the MAP (89%) of the computer workstation design produced by the proposed method was quite close to the designated accommodation percentage. The proposed design method can be of use to develop an effective anthropometric design for user-centered product development.

A Study on the Pattern for the Clean Room Garment of the Overall Type (오버롤(Overall)형 방진복의 패턴설계에 관한 연구)

  • Na, Mi-Hyang;Jang, Kyung-Jin;Lee, Yeun-Soon
    • Korean Journal of Human Ecology
    • /
    • v.6 no.2
    • /
    • pp.121-131
    • /
    • 1997
  • This study was to design the clean room garment which fits for a body and adjusts well to the action. We examined the body's changes in action through a body measurment and made a sample of the clean room garment to which had adapted the body's changes in action and evaluated the function and the appearance compared with the existing the clean room garment. The followings were summery of the results : 1. Back intersyce breadth decreased, trunk length increased and the other parts were not change. At a posture of raising hands($M_3$) in comparison with an upright posture($M_0$). Back intersyce breadth, hip length and knee length increased and the other parts were a little change. At a bowing posture($M_2$) in comparison with an upright posture($M_0$). Back hip girth, knee length, hip length and leg length increased and the other parts were not change. At a working posture on a chair($M_1$) in comparison with an upright posture($M_0$). 2. The overall clean room garment was made increasing on the changes of part of a body through measuring and body measurement. 3. From the test of the function, it became known that the devised clean room garment was superior to the existing one in the parts of neck, shoulder, armpit and elbow at a working posture on a chair($M_1$), in the parts of neck, shoulder, and armpit at a bowing posture($M_2$), and the armpit at a posture of raising hands($M_3$). The appearance was better on the whole. 4. From the examination of photographs, the waist line of the devised clean room garment was not so much pulled up as that of the existing one on moving. And when sitting down on a chair, the waist line of the existing one was pulled down while that of the devised one had no change. As above, we investigated the actual conditions of wearing the clean room garment and measured the body's changes according the various actions. So we applied these results to the devised clean room garment but we couldn't research the clean mom effect of it owing to not obtaining the measuring instrument. The aspect of ergonomics liked the feeling of wearing and fitted to the action must be given consideration to the clean room garment, and simultaneously the dust-resistant effect must be taken into consideration in order to improve the quality of the goods. Therefore, we think it should be continued the research on the dust-resistant effect, material, washing method, quality control, and size along with the aspect of ergonomics.

  • PDF