• Title/Summary/Keyword: The size of human body

Search Result 490, Processing Time 0.026 seconds

A Study on Lower Body Somatotype Classifications of Tall Stature Korean Women by KS (KS 규격의 큰 키 기준에 따른 한국 성인 여성의 하반신 체형 분류)

  • Kim, Nam-Soon;Song, Hwa Kyung;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.4
    • /
    • pp.591-599
    • /
    • 2016
  • This study analyzes the somatotype of tall stature Korean women's lower body for proper slack patterns. The study subjects consist of 350 statures over 165cm in 18-59 aged women's of Size Korea 2010. Descriptive statistics, factor analysis, cluster analysis, ANOVA, Duncan test were used for analysis using SPSS 19.0. The result are as follows: Factor 1 was the horizontal dimension of waist and hip, factor 2 was the vertical dimension of lower body, factor 3 was the horizontal dimension of the lower limbs, factor 4 was the crotch length, and factor 5 was the horizontal dimension of hip. The lower body was divided into 3 types based on analysis of the above factors. Type 1 (46.6%) represented stout type with a thick and medium length of crotch and leg. Type 2 (22.7%) represented a curve type from waist to hip with long crotch length, while short and thin leg. Type 3 (30.7%) was referred as slender type, with short crotch length, while long and thin leg.

Ergonomic Evaluation and Improvement of Bus Seat Armrest Design

  • Jung, Hayoung;Lee, Seunghoon;Kim, Moonjin;Choi, Hoimin;You, Heecheon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.2
    • /
    • pp.69-86
    • /
    • 2017
  • Objective: The present study is intended to develop an improved bus seat armrest design by evaluating various bus armrest designs from ergonomic aspects. Background: An ergonomic armrest design which considers the sitting postures and body shapes of passengers can improve the convenience and comfort of a bus seat. Method: Subjective satisfaction of each of five design dimensions (length, width, height from seatpan, shape, and angle) was evaluated for seven bus seat armrest designs in various sizes and shapes by 58 participants (28 males and 33 females) using a 7-point scale (1: very dissatisfied, 4: neutral, and 7: very satisfied). Improved bus seat armrest designs adjustable in length and rotatable to the left or right (sliding and rotating armrest, SRA) with a concave, flat, or convex shape of the upper part were developed by considering the preferred design features and the body size and shape in sitting posture and needs of passengers and then compared with a conventional armrest. Results: A bus seat armrest with a wide width (40~50mm), a long length (360mm), a lower height (213mm), and a curved shape was found significantly preferred in terms of comfort. The proposed armrest designs (SRA-convex, SRA-flat, and SRA-concave) improved satisfaction by 46~62% for length suitability, 184~216% for width suitability, 205~214% for angle suitability, 138~181% for contact area suitability, and 49~64% for height suitability, 138~174% for comfort, and 93~111% for overall satisfaction. Conclusion: The preferred design features and passengers' needs of bus seat armrest were identified and the SRA designs were recommended for better usability. Application: The ergonomic design process of bus seat armrest employed in the present study can be applied to designing armrests in various vehicles for better convenience and comfort.

Designing Elderly Women's Golfwear Slacks Patterns with Dynamic Anthropometry Using a 3D Body Scanner (3차원 바디 스캐너를 이용한 인체 치수 측정에 따른 노년 여성의 골프웨어 슬랙스 패턴 설계)

  • Ryu, Sin-A;Choi, Jong-Myoung;Park, Kil-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.4
    • /
    • pp.456-471
    • /
    • 2012
  • This study creates a method with more scientific patterns for use in designing golfwear slacks patterns that better reflect the unique characteristics of body types for elderly women aged 60 or older. This study investigates (when designing human-engineering golfwear slacks for elderly women) the body types of elderly women and design slacks patterns suitable for golf actions in order to design golfwear slacks that show excellence in function and aesthetics as well as for exercise and everyday wear conditions. The study indicated that "total crotch length" was the design element for most considerations when manufacturing golf slacks. A survey on the production of golf slacks for elderly women aged 60 or older showed that the 6 firms participating have not produced an exclusive product for women 60 years of age or older and have only manufactured an enlarged size up to 85. All 6 firms participating replied "No" two the question "Do you produce in consideration of the body types of women over 60 years of age?" Polyester-polyurethane composites were the most widely used (among golf slacks materials) as spring-autumn applications.

Preliminary Results of 7-Channel Insertional pTx Array Coil for 3T MRI

  • Ryu, Yeun Chul
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.238-243
    • /
    • 2017
  • In this research, we report the preliminary results of an insertional type parallel transmission (pTx) array that has 7-elements that are placed in the space above a patient table as a transmit (Tx) coil to give an RF transmission ($B_1{^+}$) field for the body object of a 3 Tesla (T) MRI system. In previous research, we have tried to compare the performances of different coil elements and array geometries for a pTx body image. Based on these results, we attempt to obtain a human image with the proposed pTx array. Through the simulation and experimental results, we introduce a possible structure of multi-channel Tx array and verify the utility of a multi-channel Tx body image using $B_1{^+}$ shimming. The insertional pTx array, combined with a receiver (Rx) array coil, provides an enhanced $B_1{^+}$ field homogeneity in a large ROI image as a result of $B_1{^+}$ shimming applied over the full body size object. Through this research, we hope to determine the usefulness of the proposed insertional type RF coil combination for 3 T body imaging.

Analyzing the Size and the Characteristics of Korean Ear for the Ergonomic Design of Ear Related Products (인간공학적 귀 관련 제품설계를 위한 한국인의 귀의 치수 및 특성 분석)

  • Jung, Hwa-Sik
    • IE interfaces
    • /
    • v.13 no.2
    • /
    • pp.147-156
    • /
    • 2000
  • It is known that the human stature and its related dimensions generally increase until the late teens or early twenties, remain relatively constant throughout early adulthood, and decline from early-to-middle adulthood into old age. However, there is exception that the length of the human ears, which continue to grow throughout life. In this study, 600 Korean male and female subjects aging from 17 to 89 were selected. Four different points of external ears including Pinna length, ear connection point length, Concha length, and Lobule thickness were measured along with other relative subjects' demographic data(e.g., age, stature, weight) to determine the relationship among these obtained data. The results showed that the age, sex, and different ethnic populations were functions of ear dimensions similar to the human stature. For example, the Pinna length increases as the age increases(r= 0.689, p<0.00l). The primary objective of this study was thus to provide anthropometric dimensions of Korean ear for the product designers and recommend the appropriate product design solutions in relation to human ear. Based on the results of this study, it is suggested that the continuing growth of the human body parts should be considered in the application of anthropometric data to the design of the things especially for human use.

  • PDF

Analysis on Lower Body Type of Korean Women in Their Early 20's

  • Kang, Yeon-Kyung;Chang, Hee-Kyung;Byambasuren, Enkhzul;Kim, Youn-Joo;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.15 no.6
    • /
    • pp.148-162
    • /
    • 2011
  • The purpose of this study is to analyze lower body types of women and provide information of body improvement of Korean adult female clothing product to ready-made clothes companies. As for the method of this study, it was conducted to measure the parts of the lower body of adult women at the age from 19 to 24 years, to analyze their characteristics and to categorize body types. For study, it was measured 150 female women in Seoul. Data was analyzed by used SPSS/WIN 19.0 Program. The results of this study are as follows. The means of the subjects in their early 20s are 159.8cm in height, 67.0cm in waist circumference, 91.6cm in hip and 52.0kg in weight. As a result of comparison with the $5^{th}$ Korean's human body size on measurement data, 20 items out of 33 items showed significant difference. Factor analysis was executed for 66 body measure and calculation items to draw the body construction factors of the women's lower body in their early 20s and principal component analysis was performed by orthogonal varimax rotation to clarify the measurement of factors and to derive explanatory factors. As result of Cluster analysis, body types' characteristics divide into 3 types. Type1 has tall and fat body form, type2 has shortest and curvy body form and type3 has average height and the most skinny body form.

A Review of Organ Dose Calculation Methods and Tools for Patients Undergoing Diagnostic Nuclear Medicine Procedures

  • Choonsik Lee
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.1-18
    • /
    • 2024
  • Exponential growth has been observed in nuclear medicine procedures worldwide in the past decades. The considerable increase is attributed to the advance of positron emission tomography and single photon emission computed tomography, as well as the introduction of new radiopharmaceuticals. Although nuclear medicine procedures provide undisputable diagnostic and therapeutic benefits to patients, the substantial increase in radiation exposure to nuclear medicine patients raises concerns about potential adverse health effects and calls for the urgent need to monitor exposure levels. In the current article, model-based internal dosimetry methods were reviewed, focusing on Medical Internal Radiation Dose (MIRD) formalism, biokinetic data, human anatomy models (stylized, voxel, and hybrid computational human phantoms), and energy spectrum data of radionuclides. Key results from many articles on nuclear medicine dosimetry and comparisons of dosimetry quantities based on different types of human anatomy models were summarized. Key characteristics of seven model-based dose calculation tools were tabulated and discussed, including dose quantities, computational human phantoms used for dose calculations, decay data for radionuclides, biokinetic data, and user interface. Lastly, future research needs in nuclear medicine dosimetry were discussed. Model-based internal dosimetry methods were reviewed focusing on MIRD formalism, biokinetic data, human anatomy models, and energy spectrum data of radionuclides. Future research should focus on updating biokinetic data, revising energy transfer quantities for alimentary and gastrointestinal tracts, accounting for body size in nuclear medicine dosimetry, and recalculating dose coefficients based on the latest biokinetic and energy transfer data.

A Study on the Effects of Electroencephalogram of Blocking Electromagnetic Wave Materials by useing the Nano Silver (나노 은을 이용한 전자파 차폐 직물이 뇌파에 미치는 영향)

  • Lee, Su-Jeong;Lee, Tae-Il
    • Fashion & Textile Research Journal
    • /
    • v.6 no.6
    • /
    • pp.810-814
    • /
    • 2004
  • This study is one of the fundamental researches for the development of future smart clothing and textile products using silver(Ag) nano powder. Our study was focused on the blocking or insulating effects of nano-processed textiles from electromagnetic waves. Also, for the surveying of the actual effect to human body, we measure the variation of electroencephalogram which is an indication of human physical symptoms. Among various textiles in this experiment, nano silver processed case has shown the best blocking performance from the electromagnetic waves, which decreases depending on the distance. As a reference model of working environment, we setup the visual stimuli object on the computer that is a source of electromagnetic wave. The power spectrum distribution and the incidence of electroencephalogram was measured. The analysed data has shown that, with nano-processed textiles, ${\beta}$ wave does not appear very often where ${\beta}$ wave appears only to illustrate the stable states of human's body. However, as for the materials without nano processing, the ratio of ${\gamma}$ waves in the total level of electroencephalogram becomes higher in spite of short exposure to visual stimuli in work environment, which shows that the worker becomes stressed. The ${\beta}$ wave electroencephalogram of all materials is drawn in calcarine fissure of occipital lobe to show the convergent distribution, and stronger with block-processed Nano Silver Silk(NSS). The study based on the potential risks of human diseases such as physical fatigue by electromagnetic waves, and has shown that the application of Nano Silver textile for human uses require a proper particle size of it which would not penetrate cellular tissues, and a proper binder and binding treatment for it. However, it is highly required for back-up researches to verify various aspects in applying nano silver to textile products.

The study on improving concept design of 119 paramedic helmet in Korea

  • Shin, Dong-min;Cho, Byung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.2
    • /
    • pp.71-75
    • /
    • 2018
  • In this paper, we propose an optimized size for paramedic helmets as personal safety equipment for emergency medical technician. This identified priorities for advanced loT technologies that need to be attached to paramedic Helmets. Paramedic helmets with advanced technology have been developed others, but they have not been developed for Korea. The products of kinds do not exist in Korea. Based on the average size of Korean men's heads, this derived an optimized size for paramedic helmets. The optical width of this product would be 205 mm. The length would be 265 mm. The height would be 155 mm. The verified that this size meets the requirements of the authorizing certification institution. What paramedic most need in helmets is various kinds of functionality. The communication and information transmission features. In this study, many personal safety equipment for paramedics, including the extraction of an optimal size of strong emergency head-protection helmets to protect the head of the human body on helmets based on an design. We anticipate this result to be a basis for developing an even more sophisticated and functional paramedic helmet than those that currently exist.

Drug localization by magnetic fluids of $Cu_xFe_{1-x}OFe_2O_3$

  • Park, S. I.;Y. Q. Huang;Kim, C. O.;Kim, J. H.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.88-89
    • /
    • 2002
  • Studies on drug delivery using nano-size particles of magnetic fluid and hyperthermia have been performed by some researchers [1] because interests in human health increased according to industry development. However, there are few studies on systems which can accurately control delivery of the magnetic fluids to a diseased part of body [2]. In this study, Cu-added magnetic ferrofluid was prepared and the external magnetic field system was designed for drug localization.

  • PDF