• Title/Summary/Keyword: The rapid leakage

Search Result 225, Processing Time 0.031 seconds

Rapid microcement and glycidylacrylate a Case Study on the Improvement of Water Leakage Site Applied to Mixed-use (급결마이크로시멘트 및 글리시딜아크릴레이트를 복합 적용한 누수현장 보수사례)

  • Cho, Il-Kyu;Yuh, Jae Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.241-242
    • /
    • 2019
  • This technology is a water leak repair technology using composite materials of concrete structures that block leakage of structures by injecting rapid microcement into the face of underground concrete to block water and injecting flexible glycidylacrylate. Rapid micro cement system repair materials are mixed with fine fibers to improve the flexural sensitivity of the material and to form a layer that blocks stabilized water at the back of the structure by allowing rapid and tight spatial filling during injection with high cohesion The glycidylacrylate repair material can control the expansion rate, and the external stress also has the characteristic that the form of the material is not destroyed or separated, which can also be applied to vibrating induced structures that produce repetitive fatigue loads, and has an effective durability in saline, alkali, acid (chloric acid, sulfuric acid, nitric acid).

  • PDF

Behavior of Pore Water Pressure of Agricultural Reservoir According to Raising Embankment (농업용 저수지 둑 높이기에 따른 제체의 공극수압 거동)

  • Lee, Dal-Won;Lee, Young-Hak
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.54 no.3
    • /
    • pp.11-17
    • /
    • 2012
  • In this study, an experiment with large-scale model was performed according to raising embankment in order to investigate the cause of collapse by a change in water level of reservoir. Also, the settlement and pore water pressure by high water level and a rapid drawdown were compared and analyzed. After raising embankment for inclined core, there was no infiltration by leakage. For the vertical core, the pore water pressure showed a largely change by faster infiltration of pore water than in the inclined core. In a rapid drawdown, inclined core was remained stable but vertical core showed a largely change in pore water pressure. A settlement after a raising embankment showed a larger measure of settlement than before the raising embankment. The leakage quantity before a raising embankment and an inclined extension showed no leakage. Leakage in vertical extension was measured 160 $l$. From the result, a instrument system that can accurately estimate a change of pore water pressure shall be established for a rational maintenance and stabilization of raising embankment for agricultural reservoir.

A Study on Multi-story Building Users' Opinions about the Installation of Emergency Plumbing Equipment for Preventing the Spread of Water Leakage (다층건물 사용자의 누수확대 방지용 비상배수설비 설치에 대한 의견 연구)

  • Yeon, Cheol-Soo;Seo, Jin-Hyeong
    • Journal of the Korean housing association
    • /
    • v.27 no.4
    • /
    • pp.59-66
    • /
    • 2016
  • The purpose of this study is to examine the necessity of 'emergency plumbing equipment for preventing the spread of water leakage'. It reviews social and economic costs when there is spread of water leakage and finds out that those are enormous. Expansion of water leakage causes conflicts between neighbors, economic loss and inconvenience from damages on facilities like elevator and power failure. Next, it examines the inability of existing plumbing equipment when it comes to spread of water leakage. Newly defined 'Surface Leakage' means rapid leak in the surface, and 'Internal Leakage' means seeping out slowly and gradually buried in the pipeline. It will also be analyzed by separating the concept of a leak in the two concepts of a 'Surface Leakage' and 'Internal Leakage'. It proposes emergency plumbing equipment for preventing the spread of water leakage as a solution for the expansion of water leakage. It explains general concepts of emergency plumbing equipment for preventing the spread of water leakage. It will also examine the effectiveness of the user by performing a survey of 420 multi-level building their opinion on the effects of an emergency plumbing equipments to prevent the spread of water leakage.

A Study on the Application of the Water Impermeable by the Evaluation of the Performance of Rapid Micro Cement. (급결 마이크로 시멘트의 성능평가를 통한 차수층 활용성에 관한 연구)

  • Cho, Il-Kyu;Yuh, Jae Hyung;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.345-346
    • /
    • 2018
  • In this study, various materials such as epoxy material, urethane material, cement material, and acrylic material are used to solve the water leakage occurring in underground structures. However, in the reality that the durability is insufficient and the effect is insufficient, it is aimed to improve the repairing effect by using cement and acrylics n combination. As a first study, we tried to verify the performance of rapid micro cement and cement paste and to improve the performance by checking the product properties. Three types of micro cement are evaluated. Three types of micro cement are used: fiber inclusion, fiber unfolding, and cement paste. When the material is selected for micro cement, it is applied to the field to understand the maintenance effect and durability.

  • PDF

Effect of RTA temperature on the leakage current characteristics of PZT thin films (RTA 온도가 PZT 박막의 누설전류에 미치는 영향)

  • 김현덕;여동훈;임승혁;송준태
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.709-712
    • /
    • 2001
  • The effects of post annealing temperature by the Rapid Thermal Annealing(RTA) on the electrical properties of Pb(Zr,Ti)O$_3$(PZT) thin film were investigated. Analyses by the RTA treatments reveled that the leakage current of PZT thin films strongly depend on heating temperature and time. It was found that leakage current properties of PZT capacitor were changed by heating temperature during the RTA annealing. On Pt/Ti/Si substrates, PZT films are deposited at 350 $^{\circ}C$ by rf magnetron sputtering. The X-ray diffusion (XRD) was confirmed the formation of PZT thin film. Leakage current characteristics were improved with decreasing the post annealing temperature of PZT thin film. RTA annealed film on the 700$^{\circ}C$ shows ferroelectric and electrical properties with a remanent polarization of 12.4${\mu}$C/$\textrm{cm}^2$ coercive field of 117kV/cm, leakage current J= 6.2${\times}$10$\^$-6/ A/$\textrm{cm}^2$

  • PDF

A Study on the Waterproofing Performance of Waterproofing Methods for PHC-W Earth Retaining Wall Based on Pressure Chamber Test (PHC-W 흙막이 공법의 차수방안에 관한 차수성능확인을 위한 모형 압력 수조 실험 연구)

  • Choi, Yongkyu;Johannes, Jeanette Odelia;Yun, Daehee;Kim, Chae min;Jeon, Byeong Han
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.115-125
    • /
    • 2017
  • PHC-W earth retaining wall could be constructed continuously. Various retaining wall methods such as C.I.P. etc. method require separate waterproof method. However, the PHC-W retaining wall method prevents leakage of groundwater by inserting a waterproofing material at connection part between 2 PHC piles. In this study, the experimental study on 3 waterproofing method for PHC-W retaining wall was conducted at the model pressure chamber. In the method using textile with 1-liquid type and 2-liquid type urethane, rapid leak occurred at the pressure of 120 kPa and 140 kPa or more. In the method of textile with grouting, rapid leak occurred at the pressure of 120 kPa or more, however, in this method, the rapid leakage happened at the top part and the bottom part reinforced with urethane.

Temperature and Leakage Current Characteristics with Structure of Polymeric Surge Arresters (폴리머 피뢰기의 구조에 따른 온도와 누설전류 특성)

  • Cho, Han-Goo;Lee, Un-Yong;Kim, Ha-Na
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.513-514
    • /
    • 2006
  • This paper presents the temperature characteristics with the structure of 18 kV surge arresters for distribution system. Three types of polymer arrester were fabricated and a ceramic arrester was also prepared to investigate. Below $100^{\circ}C$, three types of polymeric arresters exhibited almost the same leakage current value, but above $100^{\circ}C$, the polymeric arresters whose module was injected into polymeric housing with the grease exhibited the highest leakage current. In contrary, the arresters being manufactured by directly injecting silicone rubber onto arrester module exhibited the lowest leakage current. The rapid rising of leakage current of the polymeric arresters with the grease at $120^{\circ}C$ was because of the deterioration of the insulation characteristics of the grease between the FRP module and the silicone housing. All polymeric arresters exhibited the same surface temperature characteristics but the ceramic arresters was slower than the polymer arrester in heat emission despite the lowest leakage current. It was thought that the air layer between ZnO varistor blocks and the ceramic housing prevented the heat emission.

  • PDF

A Study on Safety Assessment of Hydrogen Station (수소충전소의 안전성 평가 연구)

  • PYO, DON-YOUNG;KIM, YANG-HWA;LIM, OCK-TAECK
    • Journal of Hydrogen and New Energy
    • /
    • v.30 no.6
    • /
    • pp.499-504
    • /
    • 2019
  • Due to the rapid spread and low minimum ignition energy of hydrogen, rupture is highly likely to cause fire, explosion and major accidents. The self-ignition of high-pressure hydrogen is highly likely to ignite immediately when it leaks from an open space, resulting in jet fire. Results of the diffusion and leakage simulation show that jet effect occurs from the leakage source to a certain distance. And at the end of location, the vapor cloud explosion can be occurred due to the formation of hydrogen vapor clouds by built-up. In the result, it is important that depending on the time of ignition, a jet fire or a vapor cloud explosion may occur. Therefore, it is necessary to take into account jet effect by location of leakage source and establish a damage minimizing plan for the possible jet fire or vapor cloud explosion. And it is required to any kind of measurements such as an interlock system to prevent hydrogen leakage or minimize the amount of leakage when detecting leakage of gas.

LIGHT-DEPENDENT CELLULAR LEAKAGE FROM CUCUMBER COTYLEDON DISCS TREATED WITH $\delta$-AMINOLEVULINIC ACID, OXYFLUORFEN, AND ROSE BENGAL

  • Lee, Hee-Jae;Cho, Kwang-Yun
    • Journal of Photoscience
    • /
    • v.3 no.1
    • /
    • pp.1-7
    • /
    • 1996
  • When cucumber (Cucumis sativus L.) cotyledon discs were floated on $\delta$-aminolevulinic acid, oxyfluorfen, or rose bengal solution under light condition following 20 h dark incubation, rapid electrolyte leakage from the tissues occurred. The electrolyte leakage from the tissues was dependent on the compounds treated, their concentrations, and the duration of light exposure to the tissues. Dark incubation before exposure to continuous white light enhanced electrolyte leakage from the tissues treated with the compounds and reduced lag period for the activity of the compounds. Electrolyte leakage from the treated tissues was greatly influenced by the light intensity to which they were exposed. Higher light intensities stimulated electrolyte leakage and reduced lag period. Porphyrin biosynthesis inhibitors, gabaculine and 4,6-dioxoheptanoic acid, completely inhibited electrolyte leakage from the oxyfluorfen-treated tissues. Protection against the activity of $\delta$-aminolevulinic acid from electrolyte leakage was complete with 4,6-dioxoheptanoic acid, but not with gabaculine. However, gabaculine and 4,6-dioxoheptanoic acid gave no such protection against rose bengal activity. In summary, our results indicate that $\delta$--aminolevulinic acid, oxyfluorfen, and rose bengal exert their effects by causing electrolyte leakage from the treated tissues in a similar manner, except that oxyfluorfen has an apparent lag period for its action on electrolyte leakage increase. All above compounds require preincubation of treated tissues in darkness and subsequent light exposure with a high intensity for their maximal activities. Our results also support that in the presence of light, $\delta$-aminolevulinic acid and oxyfluorfen cause cellular damage through the indirect generation of singlet oxygen from accumulated tetrapyrroles of porphyrin pathway, whereas rose bengal causes cellular damage through the direct generation of singlet oxygen.

  • PDF

Electrical Properties of Thin $SiO_2$ Film by Rapid Thermal Process (Rapid Thermal Process에 의해 형성시킨 얇은 산화막의 전기적 특성)

  • Lee, Cheol-Jin;Sung, Man-Young;Sung, Young-Kwon
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.246-248
    • /
    • 1994
  • The Electrical properties of thin $SiO_2$ film by rapid thermal processing have been investigated and this film has been compared with thermal $SiO_2$ film by furnace. The RTO(rapid thermal oxide) film annealed in Ar ambient represent more superior properties than thermal $SiO_2$ film by furnace at breakdown field and leakage current. The RTO(rapid thermal oxide) film annealed in $NH_3$ ambient represent more inferior properties than thermal $SiO_2$ film by furnace at electrical properties, but the capacitance was improved 15-25% than the conventional oxide film.

  • PDF