Abstract

The purpose of this study is to examine the necessity of 'emergency plumbing equipment for preventing the spread of water leakage'. It reviews social and economic costs when there is spread of water leakage and finds out that those are enormous. Expansion of water leakage causes conflicts between neighbors, economic loss and inconvenience from damages on facilities like elevator and power failure. Next, it examines the inability of existing plumbing equipment when it comes to spread of water leakage. Newly defined 'Surface Leakage' means rapid leak in the surface, and 'Internal Leakage' means seeping out slowly and gradually buried in the pipeline. It will also be analyzed by separating the concept of a leak in the two concepts of a 'Surface Leakage' and 'Internal Leakage'. It proposes emergency plumbing equipment for preventing the spread of water leakage as a solution for the expansion of water leakage. It explains general concepts of emergency plumbing equipment for preventing the spread of water leakage. It will also examine the effectiveness of the user by performing a survey of 420 multi-level building their opinion on the effects of an emergency plumbing equipments to prevent the spread of water leakage.

Keywords

References

  1. Choi, I. H., Lee, J. H., Bang, J. S., & Kim, H. R. (2011). A study on the plan of construction management for reduction of water leakage in apartment housing's underground parking lot. Journal of Architectural Institute of Korea, 31(2), 323-324.
  2. Choi, J. S., & Ahn, H. W. (2008). Search method for optimal valve setting and location to reduce leakage in water distribution networks. Journal of the Korean Society of Water and Wastewater, 22(1), 149-157.
  3. Choi, J. S., Kala, V., & Nemanja, T. (2007). Optimal valve control for reducing leakage in water distribution networks. Preceeding of the 33th Annual Conference of the Korean Society of Civil Engineers (pp. 1122-1127), Daegu, Korea.
  4. Choi, J. S., Son, D. W., Roh, S. M., Kim, D. H., & Kim, S. H. (2008). Case study of leakage reduction in a water distribution network using pressure control model. Preceeding of Autumn Annual Conference of the Korean Society of Water Quality (pp. 315-316), Seoul, Korea.
  5. Choi, T. H., Seo, N. C., & Koo J. Y. (2010). Economical analysis and effects with leakage reduction by pressure optimal management of block system. Preceeding of Spring Annual Conference of the Korean Society on Water Environment (pp. 197-198), Daejeon, Korea.
  6. Gwak, T. Y., Lee, Y. G., & Lee, D. C. (2013). Method for reducing leakage ratio in Gyeongsangnam local water supply. Changwon: Gyeongnam Development Institute.
  7. Hwang, J. (1997). Damage by water leakage from building equipment and countermeasure. Seoul: Sigongmunhwasa.
  8. Jang, K. H., Chung, S. H., & Koo, J. Y. (2005). Development of performance indicator for reducing water losses in water distribution system. Preceeding of Autumn Annual Conference of the Korean Society of Water and Wastewater (pp. 25-33), Gwangju, Korea.
  9. Kang, B. M., & Hong, I. S. (2011). A study on effective network construction of leakage sensing pipe. Journal of Korea Knowledge Information Technology Society, 6(1), 97-108.
  10. Kong, H. S. (2016). Articles written fire fighting equipment. Paju: Seongandang.
  11. Kong, M. S., Lee, H. D., Kang, S. W., & Lee, J. H. (2013). Analysis of performance indicator for leakage management in water supply system. Journal of Korea Society of Water Science and Technology, 21(5), 33-41.
  12. Koo, J. Y., Lee, H. D., Hong, I. S., Kim, J. G., & Kim, K. P. (2007). Special feature: Protection and reduction technology of the leakage in the water distribution system. Journal of Korean Society of Environmental Engineers, 29(12), 1310-1317.
  13. Lee, H. D., Jung, W. S., Kim, M. G., & Choi, J. H. (2002). Development of leakage control technologies for water distribution system. Preceeding of Spring Annual Conference of the Korean Society of Environmental Engineers (pp. 171-172), Asan, Korea.
  14. Lee, Y. S., & Yon, D. J. (2014). Improved estimation of leak location of pipelines using frequency band variation. Journal of Korean Society for Nondestructive Testing, 34(1), 44-52. https://doi.org/10.7779/JKSNT.2014.34.1.44
  15. Park, B. W., Kang, Y. J., & Jang, G. S. (2014). Plumbing system engineering. Seoul: Iijinsa.
  16. Son, K. I., Ji, H. G., & Lee, S. T. (1995). Leakage reduction effects by excess pressure control in a Water distribution network. Preceeding of the Annual Conference of the Korean Society of Civil Engineers (pp. 49-52), Seoul, Korea.