• 제목/요약/키워드: The period of Vibration

검색결과 449건 처리시간 0.032초

차량 진동특성이 주행안전도(탈선)에 미치는 영향 (The effect of rolling stock vibration on running safety(derailment))

  • 이관섭;신유정;윤지나
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.761-766
    • /
    • 2004
  • This paper describes how to measure the running safety using vibration accelerometers theoretically, and considers the effect of vibration parameters, such as amplitude and period, on the running safety by numerical analysis, which shows that the running safety are decreased as those parameters are increased.

  • PDF

성덕대왕신종의 진동 및 음향 특성

  • 김석현;김정헌;정지덕;이장무
    • 한국소음진동공학회논문집
    • /
    • 제12권7호
    • /
    • pp.534-541
    • /
    • 2002
  • Vibration and sound characteristics of King Song-Dok Bell are ivesigated. Natural frequencies. vibration modes and beat period of the bell are precisely measured. The effect of striking position and the position of nodal lines on the beat characteristics is examined. It is first found that the beat characteristics are quote different according to the position on the bell surface and clear beat is periodically generated on the circumference. It turns out that in King Song-Dok Bell, Dangjwa(the present striking position) is located at the position which makes a beat in the first vibration mode, as welt as it produces very clear beat In the second vibration mode.

Numerical investigation on multi-degree-freedom nonlinear chaotic vibration isolation

  • Jiang, Guoping;Tao, Weijun
    • Structural Engineering and Mechanics
    • /
    • 제51권4호
    • /
    • pp.643-650
    • /
    • 2014
  • A chaotic vibration isolation system is designed according to the chaotic vibration theory in this paper. The strong nonlinearity is generated by the system. Line spectra in the radiated noise maybe easily detected caused by marine vessels. It is Important to reduce the line spectra by improving the acoustic stealth of marine vessels. A multi-degree-freedom (MDF) nonlinear vibration isolation system (NVIS) system is setup by the experiment and finite element method. The model is established with finite element method. The results show that the behavior of the device gradually varies from period bifurcation into chaotic state and the line spectrum is changed from single spectral structure into broadband spectral structure. It is concluded that chaotic vibration isolation is preferable contrasted on line spectra isolation.

Research on Relationship between Natural Vibration Periods and Structural Heights for High-rise Buildings and Its Reference Range in China

  • Xu, Peifu;Xiao, Congzhen;Li, Jianhui
    • 국제초고층학회논문집
    • /
    • 제3권1호
    • /
    • pp.49-64
    • /
    • 2014
  • Natural vibration period is an important parameter for high-rise building, Based on 414 high-rise buildings completed or passed over-limit approval in China, the distribution law of natural vibration periods is analyzied. In order to satisfy the design requirements, such as global stability, story drift limit and minimum shear-gravity ratio, the reference ranges of fundamental periods $T_1$ are $0.3{\sqrt{H}}{\sim}0.4{\sqrt{H}}$ when the structural heights $H{\geq}250m$, when 150 m ${\leq}$ H < 250m, $T_1=0.25{\sqrt{H}}{\sim}0.4{\sqrt{H}}$, when 100 m ${\leq}$ H < 150 m, $T_1=0.2{\sqrt{H}}{\sim}0.35{\sqrt{H}}$, when 50 m $ {\leq}$ H < 100m, $T_1=0.15{\sqrt{H}}{\sim}0.3{\sqrt{H}}$. These can provide reference data for controlling mass and rigidity of high-rise buildings.

운전 중인 전력용 변압기(154kV)의 부하용량과 경년이 진동에 미치는 영향 (Effect on Vibration According to the Load Capability and Elapsed Year of Power Transformer(154kV) in Operation)

  • 김영달;김성중
    • 전기학회논문지P
    • /
    • 제58권2호
    • /
    • pp.172-177
    • /
    • 2009
  • Most of the causes of the failures of power transformers in operations are mechanical defects due to vibration. To identify these causes, the vibration phenomenon was measured from the power transformers in operation in the substations under the Daejeon power transmission district office of KEPCO. The measurement was performed in a 6${times}$4 structure on one side of the transformer. The vibration of the measured points was presented in 2D and 3D, and analyzed. The results according to the period in use of the transformer and the load applied to the transformer were analyzed. These results will be used as basic data to establish the vibration standard for the power transformer, In addition, with a load capability and vibration phenomenon correlation and regression analysis to identify by way of function was reached. And the vibration phenomenon pass a years with changes and to analyze correlation, was estimated to bring in the function. And then through the analysis of power transformers to set standards based on vibration data was used to.

산소 반응 교반기의 진동 특성 분석 (Characteristic Vibration analysis of the Ox-Reactor Agitator)

  • 장용석;임장익;구동식;김효중;최병근
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.986-989
    • /
    • 2008
  • Recently the agitator are being widely used in the machine plan in order to increase the petrochemical industry. The agitator normally consist of impeller, shaft, hub, reduction gear and the driving motor. It is one of the key design issue to confirm that the vibration caused by the rotation of the shaft should not coincide with the natural frequency of the shaft itself. And petrochemical industry as well as plants have been in operation for long period beyond their original design lives. In this paper the vibration of Ox-Reactor Agitator is measured for check machine condition. The result of diagnosis and solution is discussed in this paper.

  • PDF

리니어 압축기의 동적거동예측 Simulation Tool 개발 (Development of Simulation Tool to predict dynamic motion of Linear Compressor)

  • 전수홍;이효재;정의봉
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1026-1030
    • /
    • 2007
  • A linear compressor used in a refrigerator has higher energy efficiency than a reciprocating compressor. But its vibration level is still severe than others. The vibration level of linear compressor at the frequency of 60Hz is dominant since it is the exciting frequency of a motor. Experimental approach to reduce the vibration needs much effort and long period. In this paper, simulation tool to predict the vibration of the shell of the linear compressor was developed. The piston, body and shell are assumed to be rigid, while the loop pipe is flexible. The results by the developed tool showed good agreements with those by experiments.

  • PDF

진동계측에 의한 저층 철근콘크리트조 건물의 동적특성 (The Dynamic Characteristics for Low-rise Reinforced Concrete Buildings by Vibration Measurements)

  • 강동균;윤성원
    • 한국공간구조학회논문집
    • /
    • 제3권1호
    • /
    • pp.47-55
    • /
    • 2003
  • This paper is concerned with the dynamic characteristics of buildings, especially with the measurement of the natural frequencies(natural periods) and the damping. Process of ambient vibration and synchronized human excitation tests for natural period and damping are given. Data from measurement on 16 reinforced concrete buildings in Seoul and Seoul national university of technology are given. 16 Low-rise Reinforced concrete buildings are measured for ambient vibration to obtain the vibrations characteristics. The natural periods obtained by ambient vibration measurements are compared with those of forecast model suggested by standards and foreign researchers. The natural periods show a clear dependence on building height. On the other hand, the damping ration scatter under the influence of various factors, for example, building height and natural frequency.

  • PDF

2단계 소호전압방식을 적용한 보상권선형 SRM의 진동.소음특성 (Vibration and Acoustic Noise characteristic on SRM with compensating winding that two stage commutation is used at commutation action)

  • 이종근;종태욱;안영주;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.55-57
    • /
    • 1999
  • SRM Drives generate large vibration and acoustic noise because it is rotated by step pulse mmf and switching commutation mechanism. The main vibration source of SRM Drive is generated by rapidly variation of radial force when phase winding current is extinguished for commutation action. So the rapidly variation of radial force is repressed firstly to reduce vibrating force of SRM Drive. This paper suggests the vibration reduction method that SRM Drive with unidirect-short compensation winding is excited by a two stage commutation method at commutation period. This reduction effect of vibration is verified with the result obtained in the test of prototype machine.

  • PDF

교통하중에 대한 3차원 하이브리드 면진시스템의 수직 진동성능 평가 (Evaluation of Vertical Vibration Performance of Tridimensional Hybrid Isolation System for Traffic Loads)

  • 이용훈;이상현;허무원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권1호
    • /
    • pp.70-81
    • /
    • 2024
  • 본 연구에서는 진동원으로서 교통하중(고속열차)에 대해 수직 방진기능과 수평 면진기능을 조합한 3차원 하이브리드 면진시스템(Tridimensional Hybrid Isolation System, THIS)을 제안하였고, 고속열차 진동에 대한 THIS의 수직 진동 사용성 개선 효과를 해석적으로 평가하였다. 해석을 위하여 실제 16층의 공동주택을 상용구조해석프로그램의 고유치해석과 침실 바닥판에 대한 펄스 응답 분석을 통해 주요 진동모드를 식별하였고, 이 주요 진동 모드를 가지고 바닥판의 수평과 수직, 회전 자유도를 가지는 16개 층의 골조 모델을 제작하였다. 해석방법은 실제 고속철도가 통행할 때 철로와 인접한 구조물에서 계측한 가속도를 진동원으로 적용하고 THIS의 강성과 감쇠비를 변수로 상태-공간방정식을 이용하여 동적해석을 수행하였다. 그 결과, 기존 구조물의 수직 고유주기 대비 THIS의 수직 주기가 커질수록 층별 바닥판 응답이 저감되기 시작하는 임계 주기비가 다르고, 주기가 5배 이상(0.006 이하의 강성비)일 때 모든 바닥판의 가속도 수준이 비면진 대비 약 70% 이하로 감소하였다. 또한, THIS의 감쇠비에 대한 응답 제어에 미치는 영향이 매우 적은 것으로 나타났다. 마지막으로 THIS에 대한 수직 진동 사용성 개선 효과를 확인하기 위하여 비면진 구조물과 0.006의 강성비와 0.03의 감쇠비를 가지는 THIS가 적용된 구조물에 대하여 1층과 16층 바닥판 가속도를 AIJ, SCI, AISC 진동 사용성 기준에 따라 평가하였고, 기존에 주거지 사용성 기준을 만족하지 못한 데 반해, THIS 적용 후 주거지 사용성 기준을 모두 만족하는 것을 확인하였다.