• Title/Summary/Keyword: The length of the hand

Search Result 1,102, Processing Time 0.026 seconds

Factors Associated with Patient Revenues of Hand Injured Patients (수부손상환자 진료비에 미치는 영향요인 -서울시 소재 S병원의 환례를 대상으로-)

  • Yang, Jae-Young;Suh, Won-S.
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.4
    • /
    • pp.380-389
    • /
    • 2012
  • This study aims to argue fundamental issues on factors associated with revenues of hand injury patients to effectively manage hospitals specialized in hand injuries. The study employes 2,461 patients who entered S hospital from 2008 to 2010 with hand injuries. The followings are the results of the study. First, there is significant difference among occurrence of hand injuries with regard to demographics of patients. That is, it is likely to have longer average length of stay(ALOS) of male over female, of the elderly over infants and toddlers, and vice versa on average daily patient revenues. Also, compared to patients with traffic and labor insurance, patients with health insurance is likely to stay longer at lower daily cost. Fifth, demographics and incidence of hand injuries were significantly associated with average length of stay(ALOS) and average daily patient revenues. That is, male over female, age over 60 over any other age categories, patients with traffic and labor insurances over one with health insurance, cases with laceration, avulsion and bone transplantation over any other types of hand injury patients were factors significantly related to ALOS and average daily patient revenues. In sum, it is needed to focus on education and campaign to raise attentions on preventing various hand injuries. Also, managers at hospitals specialized in hand injuries should pay attention on issues such as reducing ALOS to run the organization effectively.

Effect of Somatosensory Stimulation on Upper Limb in Sensory, Hand Function, Postural Control and ADLs within Sensorimotor Deficits after Stroke (뇌졸중 환자의 상지 체감각 자극을 통한 감각, 손 기능, 자세조절 및 일상생활수행력의 변화)

  • Song, Bo-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.5
    • /
    • pp.291-299
    • /
    • 2012
  • Purpose: This study examined the improved sensory, hand function, postural balance and activities of daily living (ADL) through somatosensory stimulation, such as the facilitation of functional reaching and tactile, proprioceptive stimulus of the upper limb (UL) and hand. Methods: Seventeen stroke patients having problems with motor and somatosensory deficits were selected in Bobath Memorial Hospital adult rehabilitation center. The patients were divided into two groups; the sensorimotor deficit group (SMDG) and motor deficit group (MDG). Somatosensory stimulation on the UL, physical therapy and occupational therapy were carried out three times a week over a six week these treatments were performed in both group period. To compare each group, the following assessment tools were used: such as tactile detection thresholds (TDT), two point discrimination on the affected side (TPDas), unaffected side (TPDus) stereognosis (ST) manual function test, hand function on the affected side (HFas) and unaffected side (HFus), Postural Assessment Scale for Stroke (PASS) and Korean version Modified Barthel Index (K-MBI). Results: In the SMDG, somatosensory stimulation on the UL was statistically important for TDT, TPDas, TPDus (except for the thener), ST, hand function on HFas, on HFus, PASS length of displacement with foam (LDFSEO), and K-MBI. In the MDG, somatosensory stimulation on the UL was important for TDT, TPDas, TPDus (except index finger) length of displacement with the eyes open, LDFSEO, HFas, HFus, PASS and K-MBI. In addition, there was a significant difference in the PASS between SMDG and MDG. Conclusion: Somatosensory stimulation on the UL affects the sensory, hand function, postural control and ADLs performance.

An Analysis of Hand Measurements for Designing Size Specification for Children's Gloves (아동용 장갑의 치수 규격 설계를 위한 손 치수 분석)

  • Jeon, Eunkyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.923-934
    • /
    • 2021
  • Most apparel products have national standards for sizing; however, for gloves, national sizing standards have not yet been established. This study aims to analyze children's hand dimensions and propose a size specification for children's gloves that shows children's hand-related size information. Among the 3D measurements of sixth Size Korea Project, the measurement data of 19 dimensions related to the hands of 1,057 boys and girls aged 7-13 years old were analyzed. The distribution and growth trend of hand measurements for boys and girls demonstrated considerable mean differences and distribution trends by gender and age as per hand dimensions, which leads to the conclusion that it is necessary to show these results in the children's glove design. Based on these results, the cross-distribution maps of children's hand length and hand circumference were drafted; furthermore, the distribution relationship with an adult hand size was identified. Based on the distribution of hand sizes, the distribution of adult hand sizes overlapped with children's hand sizes was verified, and children's glove size specifications were presented. The results can be used as useful data such as measures for setting the size range and sizing system for children's gloves.

A study on hand growth of Korean adolescent boys from 14 to 19 years (한국 남자 청소년(14~19세)의 손 치수 성장 경향에 관한 연구)

  • Kim, Hyunsook;Chun, Jongsuk
    • The Research Journal of the Costume Culture
    • /
    • v.22 no.5
    • /
    • pp.702-711
    • /
    • 2014
  • This study was performed to investigate the hand size growth of Korean adolescents boys. Subjects were between 14 and 19 years (n=352). We collected the right hand size data of 19 measurements from each subject using 3D hand scanner. The total 26 hand measurements were analyzed including seven calculated measurements. Subjects were divided into three age groups (early, middle and late). Their hand size were compared. The results showed that all hand length measurements were significantly difference among age groups. Adolescent boys hands were sharply grown at age 16 years old. The hand dimensions of middle age group were compared with twenties men (n=215). There were significant differences between two groups. The middle age adolescents' hands were shorter and thicker than twenties men. Subjects were also divided by weight and height. Weight and height was closely related to hand size. The heavier and taller subjects had the thicker hand. Their fingers were longer than others. The adolescent boys and twenties men who were taller than the twenties' average height (173.4cm) were compared. Twenties men's hands were longer and thinner than that of adolescent boys. These results imply that the male adolescent hands grow short and thick in the adolescent period. Fingers continuously grow up as a long and thin shape after adolescent period.

Selectivity of Gillnet for Neon Flying Squid, Ommastrephes bartrami (LeSueur) in the North Pacific

  • LEE Jang-Uk;AN Doo-Hae;BAIK Chul-In
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.30 no.6
    • /
    • pp.916-922
    • /
    • 1997
  • This paper attempted to estimate mesh selectivity of gill nets for neon flying squid in the north Pacific Ocean. The 11 linear regressions, (P<0.05) were obtained using the data on catch ratios derived from mesh size combinations between two slightly different mesh sizes of 12 kinds of research gillnet (namely 33, 37, 42, 48, 55, 63, 72. 76, 86, 96, 105 and 115 mm in stretched mesh size). There was an increase in the optimum length with the increase in mesh size but standard deviation showed somewhat increase with the increase in the mesh size. The selectivity curves were well fitted to the length frequency distributions obtained from samples for the mesh sizes from 48 mm through 86 mm. For the mesh sizes of 33, 37 and 42 mm the DML (Dorsal Mantle Length) compositions were distributed towards the right hand-limb of the curves. The DML distributions from the 96 mm and larger meshes showed a trend towards the left hand-limb of the curves. The selectivity curves for different mesh sizes indicate that large mesh sizes catch a greater size range of squid, and the gill net fishery in the north Pacific Ocean captures effectively neon flying squid within the range of $9\~43cm$ DML.

  • PDF

A Study on Actual Conditions and Sizing Systems of Domestic Glove Production Companies (국내 장갑 제조업체의 실태조사 및 치수체계에 관한 연구)

  • Choi Hei-Sun;Kim Eun-Kyong
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.2 s.92
    • /
    • pp.116-128
    • /
    • 2005
  • The aim of this study is to understand problems with both fit and sizing system of gloves by analyzing the glove production industries with an emphasis on the sizing system, production measurement system, and general marking situation. Also, to suggest the basic raw materials for improving sizing system for gloves, actual glove control sizes were compared to the anthropometric data of the previous study Fifteen domestic production companies were participated in this study-Domestic glove production companies established their own sizing system by copying inter-national brand's glove sizing system or by their experience. The Korean Standard of gloves and the 1997 Korean Standard Anthropometrics Measurement for producing glove patterns are not considered because of its discordance with the reality of the required measurements. Domestic glove production companies used different size designation and labeling system. Size measurement unit also showed difference among the glove production companies. Some companies used 'cm', some used 'mm', some used 'inch' for the measurement unit. In general, companies produced 5 to 4 sizes in one design of glove and the production was the highest in M and L size. In 9 out of 15 companies preferred control size as hand length and hand circumference. For reference size, most of the companies preferred finger circumference, finger length, palm length, hand breadth, crotch height, and hand thickness. Actual glove sizes were compared to the anthropometric data of the previous study. The results indicated that most of the measurements of actual glove sizes were significantly larger than the anthropometric data.

CEPHALOMETRIC MEASUREMENT ACCORDING TO SKELETAL MATURITY STAGE OF THE HAND AND WRIST (수완부골성숙단계에 따른 두부방사선계칙학적 연구)

  • Choi, Hae-Woon;Kim, Jae-Hyung
    • The korean journal of orthodontics
    • /
    • v.17 no.1
    • /
    • pp.135-148
    • /
    • 1987
  • To investigate the relationship between craniofacial growth and bone maturity of the hand wrist in normal occlusion, the author took cephalogram and handwrist radiogram of 391 students (male 192, female 199) and assessed the measurements of cephalogram according to skeletal maturity stages of the hand and wrist. In this study, four skeketal stages and 36 linear, angular measurements of the cephalometrics were selected. In hand-wrist X-ray the bones used to determine skeletal maturity were the middle phalanges of the third finger, and distal epiphysis of the radius. In cephalogram, the landmark used to measure the angle and length were N, S, Po., Ar., Go., Me., Gn., Pog., Point B, Point A, ANS, PNS, Or., U1, L1, U6, L6 etc.. The results were as follows, 1. The table of mean, standard deviation, p-value from measurements were made in each group and both sex. 2. The increased measurements according to skeletal maturity were anterior cranial bese length, posterior cranial base length, ramus height, anterior facial height, posterior facial height, L1 to mandibular plane (mm), facial plane angle. In contrast to, decreased measurements were genial angle, facial cnvexity and facial plane angle. 3. Denture pattern measurements (IMPA, FMIA, occlusal plane to Go-Gn, interincisal angle, U1 to SN plane, U1 to SN plane, U1 to facial plane, L1 to facial plane etc.) .had nothing to do with skeletal maturity. 4. Skeletal maturity had close relationship with craniofacial growth, but had little to do with tooth development.

  • PDF

A Dynamic Hand Gesture Recognition System Incorporating Orientation-based Linear Extrapolation Predictor and Velocity-assisted Longest Common Subsequence Algorithm

  • Yuan, Min;Yao, Heng;Qin, Chuan;Tian, Ying
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.9
    • /
    • pp.4491-4509
    • /
    • 2017
  • The present paper proposes a novel dynamic system for hand gesture recognition. The approach involved is comprised of three main steps: detection, tracking and recognition. First, the gesture contour captured by a 2D-camera is detected by combining the three-frame difference method and skin-color elliptic boundary model. Then, the trajectory of the hand gesture is extracted via a gesture-tracking algorithm based on an occlusion-direction oriented linear extrapolation predictor, where the gesture coordinate in next frame is predicted by the judgment of current occlusion direction. Finally, to overcome the interference of insignificant trajectory segments, the longest common subsequence (LCS) is employed with the aid of velocity information. Besides, to tackle the subgesture problem, i.e., some gestures may also be a part of others, the most probable gesture category is identified through comparison of the relative LCS length of each gesture, i.e., the proportion between the LCS length and the total length of each template, rather than the length of LCS for each gesture. The gesture dataset for system performance test contains digits ranged from 0 to 9, and experimental results demonstrate the robustness and effectiveness of the proposed approach.

An in vitro evaluation of the accuracy of four electronic apex locators using stainless-steel and nickel-titanium hand files

  • Gehlot, Paras Mull;Manjunath, Vinutha;Manjunath, Mysore Krishnaswamy
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • Objectives: The purpose of this in vitro study was to evaluate the accuracy of working length (WL) determination of four electronic apex locators (EALs), namely, Root ZX (RZX), Elements diagnostic unit and apex locator (ELE), SybronEndo Mini Apex locator (MINI) and Propex pixi (PIXI) using Stainless steel (SS) and nickel-titanium (NiTi) hand files. The null hypothesis was that there was no difference between canal length determination by SS and NiTi files of 4 EALs. Materials and Methods: Sixty extracted, single rooted human teeth were decoronated and the canal orifice flared. The actual length (AL) was assessed visually, and the teeth were embedded in an alginate model. The electronic length (EL) measurements were recorded with all four EALs using SS and NiTi files at '0.5' reading on display. The differences between the AL and EL were compared. Results: The results obtained with each EAL with SS and NiTi files were compared with AL. A paired sample t test showed that there was a statistical significant difference between EAL readings with SS and NiTi files for RZX and MINI (p < 0.05). The accuracy of RZX, ELE, MINI and PIXI within ${\pm}0.5 mm$ of AL with SS/NiTi files were 93.3%/70%, 90%/91.7%, 95%/68.3%, and 83.3%/83.3%, respectively. Conclusions: The results of this study indicate that Root ZX was statistically more accurate with NiTi files compared to SS files, while MINI was statistically more accurate with SS files compared to NiTi files. ELE and PIXI were not affected by the alloy type of the file used to determine WL.

A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source (발열체와 부분 열림 수직벽을 갖는 사각 공간내 자연대류 특성 해석)

  • Shim, Dong-Sik;Kang, Bo-Seon;Cha, Dong-Jin;Ju, Won-Jong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.322-327
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right vertical wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The openging length as well as the divider length greatly affects the degree of inflow and outflow of air. With a small opening, the opening doesn't affect much the upward warm air flow resulting in the symmetric temperature distribution. On the other hand, with the increase of the opening length, the inward cold flow moves the upward flow to the left direction. With the increase of the divider length, temperature in the lower region of enclosure becomes higher for the small opening and lower for the large opening.

  • PDF