BIM and Fire Safety Engineering - Overview of State of The Art

  • Davidson, Anne;Gales, John
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.251-263
    • /
    • 2021
  • Fire safety engineering is a critical specialization to include in the design of a tall building yet is often excluded from the Building Information Model (BIM) and integrated design process. The design of fire safety systems is interdependent with building/structural geometry, HVAC, mechanical, and electrical systems. A BIM is a 3D visual representation that stores data on these kinds of systems. The compatibility between BIM and fire safety design seems obvious yet has received a dearth of attention in structural (fire) engineering literature. The authors herein have reviewed over 40 recent papers on utilizing BIM for fire safety engineering, focusing on contemporary literature to obtain a more up-to-date review of the state-of-the-art. The resulting trends, technologies, research gaps, and methodologies are presented in this paper. Adoption of BIM in fire safety engineering is slow and behind other disciplines which may be improved if research involved more industry partners. For BIM technology to reach its potential, industry manufacturers need to provide high LOD fire BIM objects, fire engineers and researchers need to collaborate on future advancements, and building owners/management need to be educated on how to use the benefits provided.

초고층 건축물 소방안전관리의 기본방향에 관한 연구 (A Study on the general direction of Fire-Fighting Safety management in high-rise buildings)

  • 최만철;김병석
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.67-75
    • /
    • 2011
  • Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.

공동주택의 화재안전성능 평가방안에 관한 연구 (A Study on Evaluation Plan of Fire Safety Performance for Public Building)

  • 구재현
    • 한국융합학회논문지
    • /
    • 제10권4호
    • /
    • pp.25-32
    • /
    • 2019
  • 소방활동 관점에서 공동주택은 화재시 구조적 관리적 문제점을 가지고 있으므로 피난장애 발생 및 연소확대 위험성이 큰 것으로 조사되었다. 공동주택의 다양한 화재취약요인들을 분석한 결과, 안전시스템, 소방시설, 건축물 안전, 일반안전 분야로 평가분야를 도출하였으며 이에 따른 평가요소들을 제시하였다. 이와 함께, 6개의 국내외 공동주택 화재안전성능 인증제도 현황을 비교분석함에 따라 국내외 인증제도의 특성을 분석하였다. 결론적으로, 인증제도의 5개의 융합적 추진방향 및 4개 평가분야별 22개 평가항목들을 도출하였으며, 이를 기반으로 3개의 공동주택 화재안전성능 인증제도의 융합적 도입 방안을 수립하였다.

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF

고속선의 새로운 국제안전규칙 -화재안전규칙에 대하여- (International Code of Safety Regulation for High Speed Craft - as compared with Fire Safety Regulation-)

  • 박영규;신영식
    • 해양환경안전학회지
    • /
    • 제3권1호
    • /
    • pp.111-123
    • /
    • 1997
  • The application of all regulations during building phase, plus constant vigilance in operation is essential to reducing the risk of fire aboard. A Safety by design approach is increasingly important. Fire safety regulation can solve problems which are hard to be solved by HSC code(International Code of Safety for High Speed Craft). Recently HSC code is applied for ship design development or guidance to the designer and demonstrates many advantages. In this pages, ship fire Safety are realistically modeled as ship design and the shipboard fires & muster stations are analyzed using HSC Code.

  • PDF

화재안전성능분야에 대한 표현방법에 관한 한.일 의식조사 비교 연구 (A Study on The Comparative Survey of Expression Methods for Fire Safety Performance in Korea and Japan)

  • 구인혁;오성해;서광현;이재영;좌등박신;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.27-34
    • /
    • 2008
  • As for the performance related to a fire safety like fire resistance efficiency and evacuation safety etc. It is the ain of this study to investigate the comparative survey of expression methods for fire safety performance in Korea and Japan. The results of this study that there are so difference between Japan and Korea and suggests that the necessity for converting the fire risk calculated by an advanced technique into a simple expression.

  • PDF

CEN/TS 45545 출범에 따른 철도차량 화재안전 기술 동향에 대한 연구 (A Study on Technical Trend of Fire Safety on Railway Vehicles for Launch CEN/TS 45545)

  • 성시영;우이완;박재홍
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1768-1773
    • /
    • 2010
  • CEN/TS 45545 is Europe consolidation standard for fire safety on railway behicles. This is based on the International Union of Railways(UIC) and different European countries. It is intended to protect passengers and staff in railway in the event of a fire on board. It will be prepared in 2012. Based on this consolidate standard, they are going to make single market, for raising technical competitiveness, technical innovation and globalization of that standard. For this reason, European academies, manufacturers, and sub-manufacturers confer and stady animated about CEN/TS 45545. In Korea, get out the safety assessment for ues incombustible interior material, the needs of quantitative analysis on fire protection, demand on recognition of fire protection scenario, and define about fire load analysis are becomin more and more important. Therefore, this paper will estimate and compare Flammability, Smoke Density, Toxicity Index( this is the key point for appraised fire safety performance of material) between CEN/TS45545 and fire standards on railway vehicle. Then suggest criteria for fire safety on railway vehicles.

  • PDF

경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석 (Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period)

  • 김민호;이석희;이민철;이상규;이주은
    • 한국안전학회지
    • /
    • 제35권5호
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안 (Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes)

  • 이홍상;이재영;공하성
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.