• 제목/요약/키워드: The fire safety

검색결과 3,694건 처리시간 0.03초

선박화재 적용 단백포 소화약제의 안정제에 따른 소화특성 (Characteristics of Protein Foam Agent by Stabilizer on the Ship Fire Extinguishment)

  • 이응우;신창섭
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.79-85
    • /
    • 2015
  • Onboard fire extinguishing system is important to protect cargo and human lives and every oil tanker has foam type fire extinguishing system. Because of environmental problem, agent which contains materials such as Perfluorinated compounds are regulated and the development of the environmental friendly agent is required. The protein foam has less environmental pollution problem and has an excellent fire extinguish performance to oil fire. In the research, bivalency metal salts were added as stabilizer to increase fire resistance and stability of the foam. Ferrous sulfate, Iron chloride and Nickel chloride were used and to adjust to vessel, sea water was applied. As a stabilizer increased, the expansion ratio was raised. However 25% drainage time was decreased over 2.0 wt.% which is knowable that the foam brokes easily. The amount of generated foam was measured to check fluidity of foam and it appeared that when $FeSO_4$ 1.2 wt.% was added, the amount of generated foam reached large and also the 25% drainage time was high. To evaluate the fire extinguishing performance for oil fire, the small scale oil fire test was executed. When $FeSO_4$ 1.2 wt.% was added, fire extinguishing time was in its shortest which informs fluidity of foam and stability are important factors on fire extinguishing efficiency.

전기히터의 화재위험성에 관한 실험연구 (An Experimental Study on the Fire Hazards in Electric Heater)

  • 홍성호;이복영;박상태;유현종
    • 한국안전학회지
    • /
    • 제22권2호
    • /
    • pp.36-40
    • /
    • 2007
  • This study presents on the analysis fire hazards of electric heater. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate normal condition and abnormal condition. The abnormal condition experiment is simulated in which combustibles are placed near by electric heater. Vertical burning test(UL 94) is conducted for the fire retardant experiment. The results show that fire hazard is high in case of abnormal condition. And Material of electric heater has not fire retardant performance. In this paper, we suggest to add temperature fuse in electric heater for reducing fire hazard.

폭렬현상을 고려한 RC구조물의 PBD기반 구조내화설계 기술개발에 관한 연구(II) - PBD기반 구축을 위한 조사연구 - (A Study on the Structural Fire Resistance Performance Design of RC Structural according to the Explosive Spalling - The Investigate Study on the PBD for Fire Resistance -)

  • 이재영;김세종;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.202-209
    • /
    • 2008
  • Performance based fire engineering design is being adopted around the world as a rationed means of providing efficient and effective fire safety in Building. This development is being supported by the adoption of performance based codes which specify the objective and minimum performance requirements for fire safety traditional design for fire safety which is still practiced in many countries, relies on "prescriptive" codes which specify how a building is to be built, which no statement of objective and little or no opportunity to offer more rational alterative design. It is the aim of this study to investigate and analyze the research direction of structural fire resistance design of RC structures for recommendation of PBD in Korea.

  • PDF

서점의 적재가연물의 연소특성에 관한 실험적 연구 (Experimental Study on Combustion Characteristics of Live Fire Load in a Bookstore)

  • 남동군
    • 한국화재소방학회논문지
    • /
    • 제25권5호
    • /
    • pp.47-53
    • /
    • 2011
  • 건축물 적재가연물은 종류 및 양 등의 특성에 따라 화재지속시간과 화재규모 등에 크게 기여한다. 서점은 다른 건축용도보다 가연물이 다량 적재되어 있으므로 화재발생시 화재위험성이 클 가능성이 있다. 그러나 한편으로는 서점 내부의 서적은 연소하면 탄화층이 형성되고 적재가연물량에 비해 노출표면적이 작기 때문에 화재시 열분해가스의 생성이 작을 가능성도 있다. 이러한 가능성을 다양한 실험을 통해 파악하여 서점의 화재안전설계에 합리적으로 반영할 필요가 있다. 따라서 본 연구에서는 서점의 성능위주설계에 활용하기 위하여 적재가연물을 재현한 시험체를 가열로에 넣고 ISO834-1:1999 표준가열곡선에 따라 가열하는 일련의 실험을 실행하였다. 이 실험 결과를 바탕으로 서점의 적재가연물의 연소발열성상을 파악하고 성능위주설계에 필요한 연소속도 및 열방출률 등을 제시하였다.

헬기에 의한 산불공중진화 효과 및 안전성 인식 연구 (A Study on the Recognition of Effectiveness and Safety of the Helicopter Aerial Fire Attack)

  • 배택훈;이시영
    • 한국화재소방학회논문지
    • /
    • 제26권2호
    • /
    • pp.97-104
    • /
    • 2012
  • 본 연구에서는 산불이 발생하면 대형화 위험성이 증대하여 항공기 특히, 헬기의 산불진화 활용성이 점차 증가되고 있는 관점에서, 산불진화 과정 중 헬기에 의한 공중진화기술과 안전성 향상은 효율적인 산불진화의 성공요인으로서 매우 중요하다. 따라서 우리나라 산불전문기관인 산림청 산림항공본부의 조종사들에 대하여 산불현장에서 실제 경험한 내용을 토대로 설문조사를 실시하여 효율적인 공중진화기술 및 안전성 향상 방안을 제시하였다.

노후 건축물의 안전성능 평가항목 (Safety Performance Assessment for a Aged Building)

  • 권동찬;이용재;이찬식
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2004년도 제5회 정기학술발표대회 논문집
    • /
    • pp.296-300
    • /
    • 2004
  • 건축물이 노후화되면 구조안전성능, 설비 및 마감의 안전성 등이 저하된다. 기간의 경과와 사용조건에 따라 성능 및 건축물의 가치는 변하기 때문에 건축물의 효율적인 유지관리 및 건축물의 매매 시 발생할지도 모르는 분쟁으로 인한 소비자 보호 차원에서 건축물의 안전성능에 대한 정확한 평가가 필요하다. 이 연구에서는 건축물의 안전성능에 관한 기존의 연구 결과와 성능평가 모델들을 비교 분석하여 건축물의 안전성능을 객관적으로 평가할 수 있는 항록을 선정 $\cdot$제시하였다. 이 연구 결과는 건축물의 적정 설계 $\cdot$시공 유지관리를 통하여 장수명화를 유도하기 위한 수단의 하나로 이용할 수 있을 것으로 판단되며, 앞으로 진행되는 건축물의 안전성능평가를 위한 기준 및 절차 연구의 기초 자료로 활용될 수 있을 것이다.

  • PDF

하이브리드 복합재 철도차량 차체의 화재 안전성 평가연구 (A Study on the Fire Safety of a Hybrid Composite Train Carbody)

  • 김정석;이덕희;정우성;조세현
    • Composites Research
    • /
    • 제21권4호
    • /
    • pp.1-6
    • /
    • 2008
  • 본 논문에서는 탄소/에폭시 면재와 알루미늄 허니콤 심재를 갖는 바디와 스테인레스 언더프레임을 갖는 철도차량 차체에 대한 화재안전성평가 시험을 수행하였다. 이를 위해 실규모 차체를 제작하고 이를 이용하여 시험을 수행하였다. 시험에 적용된 차체는 내장재가 포함되지 않은 차체와 내장재를 포함을 차체 두가지를 이용하였으며 시험조건은 대구지하철 화재사고 시나리오에 근거하여 설정하였다. 시험결과 차체 및 내장재 표면의 최대온도는 각각의 발화온도에 미치지 못함을 확인하였고, 차체 내부에 화염전파도 발생하지 않았다.