• Title/Summary/Keyword: The dry wall

Search Result 312, Processing Time 0.027 seconds

An Evaluation on the Sound Insulation Performance of Drywall for High-Rise Buildings (초고층 건물에 적용 가능한 건식벽체의 차음성능 평가)

  • Lee, Sang-Woo;Yoo, Ho-Chun;Lee, Su-Yeal;Jung, Gap-Chul;Jung, Young-Min
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, the structural system of public residential buildings has been changed from the reinforced concrete (RC) wall system to the (PC) wall and moment resisting systems. Thus, it is important to develop the suitable wall system in accordance with the trend of the modern structural system. This paper presents the basic study on the suitable boundary wall in high-rise buildings. The research also demonstrates the evaluation results on sound characteristics in the aspect of sound insulation. The evaluation of sound insulation capability for the commercialized wall structure was conducted based on literature survey while the measurement of sound insulation capability for the light-weght EPP concrete was performed in according to KS F2808 in laboratory. The main objective of this research is to propose the most suitable dry wall system as a sound insulation structure through the comparison and analysis of frequency characteristics and weight-acoustic attenuation.

A Study on the Prediction of Paint Dry Time at Ship Block's Inner Wall Placed in the Paint Dry Facility Adopting the Hot Air Supply System (열풍 공급 방식의 도장 건조 설비에서 선체 블록 도장 건조 시간 예측에 관한 연구)

  • Song, Yoo-Sok;Seol, Sin-Su;Yoon, Kwang-Won;Yang, Moon-Sik;Jeong, Jae-Hwan;Yoon, Hyun-Sik
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2011.09a
    • /
    • pp.75-81
    • /
    • 2011
  • An indirect concept and method is proposed to predict the paint dry time at the inside wall of ship block. To implement this concept on computer program, optimal hot air supply-exhaust system of paint dry facility was designed by CFD simulation and experiment was performed to get the paint dry time curve according to various paint dry conditions. After combining the block inside environment from the simulation results and the paint dry time prediction curve from the curve-fitting of experimental result, the GUI program which can be executed in general PC OS has been finally developed.

  • PDF

A Study on the Evaluation of The Load Resistancy of Lightweight Wall against Wall Attachments through Field Tests (현장실험을 통한 건식경량벽체의 부착물에 대한 하중 저항성 평가에 관한 연구)

  • Kim, Tae-Ik;Lee, Ju-Min;Kim, Sang-Heon;Choi, Soo-Kyung;Seo, Chee-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.183-184
    • /
    • 2015
  • Recent structural approach of the House of Commons has been an increase in demand for dry wall light due to a change in load bearing composite structure of a flat plate type structure under the name of long-life housing, attach the attachment to the wall as the needs of the residents of reserved space increases things that are on the rise. However, depending on the strength of collapse accidents is shown wall and recent wall deposits are required, a load resistance evaluation method of the deposit of the need is the situation. Therefore, in this study, for the evaluation of the evaluation of dry lightweight wall as widely used gypsum board and ALC lightweight wall of two types of laboratory the wall through the previous studies to be installed in direct co-housing to the target and field experiments I want to evaluate the different points.

  • PDF

A Review of the Types and Characteristics of Horizontal Load Affecting the Structural Safety of the Lightweight Dry Walls (건식 경량벽체의 구조안전성에 영향을 미치는 수평하중의 종류 및 특성 고찰)

  • Song, Jung-Hyeon;Roh, Yong-Woon;Kin, Ki-Jun;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.43-45
    • /
    • 2013
  • The purpose of this study is to obtain basic data for making performance criteria about the structural safety of lightweight dry wall later by examining types and characteristics of horizontal load acting on the wall. The subjects applying horizontal load to the wall are human and objects. The types of horizontal load are classified as static load and dynamic load depending on the difference of acting time. The magnitude of horizontal load "0.25kN/㎡" defined by KBC 2009 has no significant meaning since it is the unsubstantial nominal load. The result of examining types and characteristics of horizontal load is as follows. (1) Static load by human needs to have more systematic investigation including differences in wall hardness and human weight. (2) Dynamic load by human needs to raise the significance of study result by increasing the number of subjects. (3) Dynamic load by objects needs to accumulate the load specific data for various load subjects considering real situations.

  • PDF

A Study of the appraisal for adhesive stability classified by tile bond agent on the dry wall surface (건식벽체에서 접착제 종류에 따른 타일부착 안전성 평가에 관한 연구)

  • Um Chan-Young;Sun Yoon-Suk;Kwon Shi-Won;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.173-178
    • /
    • 2005
  • The tile construction methods for existing have been used materials within limit which adhesion by wet method in masonry wall and concrete structure. These existing adhesive tech can caused many problems in construction of large and reform tile, after that it can be happened loose scale, peel off, falling off tile by heat and vibration or impact. In according to, this study is to test tile for bond stability, adhesive property by impact, vibration. low property by heat and then, we have the results as below; (1) The tile adhesive stability can be effected as adhesive area between bond agent and tile, adhesive area can more wide and press enough to ensure property. (2) Existing adhesive strength and standard relative tile construction is limited to adjust performance tile on the concrete and masonry wall. In summary, It is necessary to establish standard of performance and test method to ensure tile adhesive salability in dry wall.

  • PDF

Anatomical Characteristics and Air-dry Density of Young Trees of Teak Clones Planted in Indonesia

  • Hidayati, Fanny;Ishiguri, Futoshi;Marsoem, Sri Nugroho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.4
    • /
    • pp.463-470
    • /
    • 2017
  • The objectives of this study are to obtain the basic knowledge of anatomical characteristics and wood properties of thinning trees of young teak (Tectona grandis L.F.) for fulfill the timber demand in Indonesia. Nine thinning trees of 5-year-old teak clone trees were used for analyzing the cell morphology and air-dry density. Vessel diameters in pore and outer pore zones were 165 and $90{\mu}m$, respectively. Mean value of fiber diameter, cell wall thickness, and fiber length in outer pore zone were $14.6{\mu}m$, $2.07{\mu}m$, and 1.04 mm, respectively. In addition, mean value of air-dry density was $0.55g/cm^3$. The measurement and values of vessel diameter, fiber diameter, cell wall thickness, fiber length and air-dry density in the experimental had lower than those in the older teak. Therefore, it could be suggested that the wood from thinning young teaks was not appropriate as construction material, but it could be used for furniture which do not need high of strength properties. Furthermore, since the measurements values of anatomical characteristics were still increasing from pith to bark, it could be suggested that 5-year-old teak clones are still in a juvenile phase. Positively significant correlations were found between air-dry density and cell wall thickness, indicating that cell wall thickness is strongly correlated with wood density of teak.

A Study on the Structure Behavior of Dry-assembled Wall with Concrete Blocks subjected to Cyclic Lateral Load (콘크리트블록으로 건식조립된 벽체의 수평반복하중에 대한 구조거동 연구)

  • Lee, Joong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.440-447
    • /
    • 2020
  • Masonry structures are used as bearing walls in small buildings, but they are generally considered non-bearing walls. They are used as partition walls that divide the interior spaces of the frame structures of buildings. In addition, wetting techniques that use mortar as an adhesive between blocks or bricks in construction are vulnerable to climatic conditions, especially cracks in mortar, which can cause conduction collapse of the walls in seismic loading. The purpose of this research was to propose a dry concrete block construction method that complements the weak axial shear stiffness and improves the weakness of the wet construction method as well as to investigate its structural behavior. In this study, the material properties of concrete blocks were examined, and the seismic performance of the proposed dry assembly structure was verified by structural behavior tests on horizontal cyclic loads. First, in these study results, concrete blocks can be applied to the dry block construction method instead of wet construction methods because they secure more than C-type blocks in KS regulations. Second, the structural performance of the wall against a horizontal cyclic load indicates that the resisting force of the assembly block wall is increased by increasing the horizontal length of the wall, forming several diagonal cracks. Finally, the proposed dry block wall structure requires a seismic performance assessment considering that the ratio of the shape of the wall by height and length is considered a major influence variable on the structural behavior under a horizontal load.

Sound Insulation Performance According to Stud Shape of Dry Wall (스터드 형상에 따른 Dry Wall의 차음성능변화)

  • An, JangHo;Kim, KyungHo;Lee, HunSeo;Kim, SeongHoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.407-412
    • /
    • 2013
  • In dry wall, noise is passed through gypsum board and stud. Noise makes gypsum board vibration. Then, the vibration passes through stud and gypsum board as resonation. And radiation as noise from surface of gypsum board into adjacent room. At this moment, according to thickness, placement and cross-section of stud, noise transmission ratio changes. Thicker stud has better sound insulation performance. Studs are apart from each other, has better sound insulation performance. But, single stud structure has restriction of thickness and arrange of studs. In this article, Sound insulation performance varies depending on the shape of the studs were studied.

  • PDF

Feasibility study of an earth-retaining structure using in-situ soil with dual sheet piles

  • An, Joon-Sang;Yoon, Yeo-Won;Song, Ki-Il
    • Geomechanics and Engineering
    • /
    • v.16 no.3
    • /
    • pp.321-329
    • /
    • 2018
  • Classic braced walls use struts and wales to minimize ground movements induced by deep excavation. However, the installation of struts and wales is a time-consuming process and confines the work space. To secure a work space around the retaining structure, an anchoring system works in conjunction with a braced wall. However, anchoring cannot perform well when the shear strength of soil is low. In such a case, innovative retaining systems are required in excavation. This study proposes an innovative earth-retaining wall that uses in situ soil confined in dual sheet piles as a structural component. A numerical study was conducted to evaluate the stability of the proposed structure in cohesionless dry soil and establish a design chart. The displacement and factor of safety of the structural member were monitored and evaluated. According to the results, an increase in the clearance distance increases the depth of safe excavation. For a conservative design to secure the stability of the earth-retaining structure in cohesionless dry soil, the clearance distance should exceed 2 m, and the embedded depth should exceed 40% of the wall height. The results suggest that the proposed method can be used for 14 m of excavation without any internal support structure. The design chart can be used for the preliminary design of an earth-retaining structure using in situ soil with dual steel sheet piles in cohesionless dry soil.