• 제목/요약/키워드: The causes of fire

검색결과 509건 처리시간 0.028초

금원시대(金元時代)의 의서(醫書)에 나타난 신경정신질환(神經精神疾患)에 대한 고찰(考察) (The literatural study of investigating the contents associated with the neuropsychosis in the medical books published in the times of Chinese dynasty of Jin and Yuan)

  • 채종걸;이상용
    • 혜화의학회지
    • /
    • 제9권1호
    • /
    • pp.725-743
    • /
    • 2000
  • This study was intended to investigate the contents associated with the neuropsychosis in the medical books published in the times of Chinese dynasty of Jin and Yuan. As a result, the following findings were drawn. 1. As for palpitation from fright and severe palpitation, the medical schools in the times of Chinese Jin and Yuan dynasties viewed their causes as heart-fire, shuiqichengxin, blood vacuity, phlegm and so on and presented a prescription for each cause for them. 2. As for psychosis, medical books published in the times of Chinese Jin and Yuan dynasties accurately divided and discussed epilepsy and viewed their causes largely as Yangming heat, phlegm of chest and heart-fire. And a number of medical schools made use of such therapeutics as sweating, vomiting and diarrhea therapies. 3. As for headache, medical books published in the times of Chinese Jin and Yuan dynasties presented their causes as fire and heat, phlegm heat, phlegm and so on and classified the aspect of headache in detail. As for vacuity rexation and dysphoria, medical books at that time saw their causes as fire and heat, heart-fire, blood vacuity and so forth and presented a prescription for them accordingly. 4. Liu Wan Su was the Hanliang school. He viewed the etiological cause for psychopathy as fire and heat and prescribed largely the medication of cold nature for it. 5. Zhang Cong Zheng belonged to the Gongxia School. He viewed the etiological cause for psychopathy as fire, phlegm and so forth and made use of sweating, vomiting and diarrhea therapies. Especially, he used the 'Jingzhepingzhe' therapy as a method to treat the symptom of fright. 6. Li Gao did not any specific mention of psychopathy and divided headache due to internal injury and headache due to external contraction. 7. Zhu Zhen Heng viewed most of the etiological causes for psychopathy as phlegm, fire and deficiency of blood and attached importance to such its therapeutics as resolving phlegm, cleaning away fire and nourishing Yin. 8. Wang Hao Gu did not present the specifically common etiological cause and prescription for psychopathy but described the cause and prescription for headache, dysphoria, maniac speech, palpitation and so forth. Luo Tian Yi presented the process of psychosis due to abnormal therapy for cold demage and prescription of it. 9. Wang Lu made a detailed explanation about the therapeutics of five types of stagnated syndrome and said that stagnated syndrome became the major cause for them in the occurrence of such psychopathy. Wei Yi Lin presented the prescription and medication for comparatively diverse mental diseases such zhong-qi, severe palpitation, palpitation for fright, impaired memory, vacuity rexation, headache, psychosis.

  • PDF

Causes of the Fire at an Indoor Shooting Range in Busan

  • Park, Woe-Chul;Lee, Nae-Woo;Jeong, Lee-Gyu
    • International Journal of Safety
    • /
    • 제9권1호
    • /
    • pp.1-5
    • /
    • 2010
  • On-site examinations and fire simulation were carried out to speculate on causes of the fire at an indoor shooting range in Busan. An experiment on the ignitability of unburned gunpowder was also conducted. Cigarette was the most likely source of ignition for the fire, while impact of a stray bullet failed to ignite the unburned gunpowder. The explosion in the shooting area was presumed to be caused by violent combustion of the polyurethane foam and unburned gunpowder accumulated on it. Fire safety measures include prohibit of use of profile polyurethane foam, complete clean-up of unburned gunpowder, and removal of steel components from the bullet trap.

철근콘크리트 구조물의 내화성능에 관한 연구 (A Study on the Fire Resisting Properties of Reinforced Concrete Structures)

  • 김무한;송하영
    • 한국화재소방학회논문지
    • /
    • 제2권1호
    • /
    • pp.3-10
    • /
    • 1988
  • Concrete is incombustible and has good fire resisting properties, i. e. when exposed to fire it continues to perform satisfactorily for a reasonable period of time. Nevertheless, with time and high temperature gradient, brought about the fire, causes cracking and spatting. Further deterioration and loss of strength are caused by gradual dehydration of concrete paste. This paper is aimed to make a proposal for the design and construction of reinforced concrete structures with more sufficent resistance to fire by the theoritical analysis, which is base4 on investigation of general damages by the fire and change of properties on concrete influenced by high temperature.

  • PDF

엔진정지 중 전기적인 원인에 의해 발생한 자동차화재의 분석 연구 (A Study on Analysis on an Automotive Fire Case that Broke Out due to an Electrical Cause during Engine Stopping)

  • 이의평
    • 한국자동차공학회논문집
    • /
    • 제21권1호
    • /
    • pp.9-16
    • /
    • 2013
  • Although it is widely accepted that a fire can occur due to electrical causes even when an engine stops, there is little introduction of detailed case analysis. This study analyzed a fire case caused by an electrical cause during engine stopping at parking lot in detail. Moreover, it was revealed that the fire was mainly caused by design defect.

열차 화재안전성 향상을 위한 위험사건 정의 및 원인분류 연구 (Classification of Hazard Events and Causes for Railway Fire Accident)

  • 곽상록;왕종배;박찬우;박주남
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1163-1167
    • /
    • 2007
  • Many railway safety measures are carried out after Daegue subway fire accident. Such as replacement of train interior material, fire extinguish and toxic gas evacuation facilities, exercise on emergency response, setting up of national safety management system, and safety technology research. But these safety measures are not considered by system safety due to lack of risk and hazard information. In order to assess fire risk on system level, we proposed hazard events and causes classification for railway fire accident risk analysis.

  • PDF

노후 분말소화기의 폭발사고 원인과 예방대책에 관한 분석 (Analysis of the Precautionary Measures and Causes on Explosion Accidents of a Old Dry Chemical Powder Extinguisher)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.91-99
    • /
    • 2012
  • 분말소화기를 조작하거나 해체하는 과정 중에 아주 드물게 사상자가 발생하는 경우가 있다. 부식된 분말소화기는 조작 중 또는 해체(폐기)과정 중에 폭발하면 로켓과 같이 위쪽으로 솟아오르면서 소화기 조작자나 해체과정 중인 사람의 머리나 가슴, 목 부위 등을 쳐서 사상사고를 발생하게 한다. 이 논문에서는 분말소화기파열사고사례를 알아본 후, 파열사고의 원인과 파열로 인한 반동력, 예방대책에 대해 알아보았다. 소화기 파열사고의 예방대책으로 훈련이나 교육에 부식된 소화기의 사용 자제, 부식된 소화기에 대한 위험성 교육 및 홍보, 기설치 가압식분말소화기에 파열위험성 표시, 내용연수 표시 의무화, 일정기간 경과 소화기에 대한 수압검사 제도의 도입 검토, 폐소화기 회수시스템 구축, 폐소화기의 재활용시스템 구축, 노후소화기관련 상담창구 운영 등을 제안하였다.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로- (Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.57-66
    • /
    • 2018
  • 29명이 사망하고 40명이 부상을 입은 제천 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 원인을 초기대응과 관리적인 측면을 중심으로 분석하였다. 초기대응 측면은 119신고 지연, 2층 세신사 비상구로 피난유도를 하지 않음, 1층과 3층 비상계단쪽 방화문 개방 상태 유지, 3층 주계단실 쪽 방화문 닫지 않음, 비상방송을 하지 않음으로 분석하였다. 관리적인 측면은 1층의 스프링클러설비 알람밸브 폐쇄, 소방펌프 제어반에서 기동 정지 위치에 놓음, 주차장 반자 안 누수 및 누전 방치, 2층 여탕의 휴게실 피난구유도등이 가려져 있고 비상구에 물건이 적치됨, 2층 자동문의 조작버튼 불량상태로 방치, 형식적인 소방안전관리, 소방시설 부실한 자체점검, 방화셔터와 배연창 미작동으로 분석하였다.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 - (Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.86-94
    • /
    • 2018
  • 제천 스포츠센터 화재로 29명이 사망하고 40명이 부상을 입었다. 이 논문에서는 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 요인을 분석하기 위해 저자의 화재조사 결과를 토대로 건물과 설비의 구조적인 요인을 분석하고 있다. 건물과 설비의 구조적인 요인은 필로티 구조의 주차장, 필로티 주차장과 로비 사이 방화구획 미비, 필로티 주차장에 스프링클러설비 미설치, 1층 주계단에 방화문 미설치, 옥상에 소화수조 미설치, 2층 주출입구에 벽체 매립형 방화문 설치, EPS실 및 배관 피트 층별 방화구획 부실, 배수배관 연결부의 누수, 화물용 승강기의 승강로와 실내에 면하는 벽체에 합판 설치, 폐쇄형 옥상구조로 개조, 주차장 반자 안쪽 천장에 스티로폼 단열재 부착, 2층 여탕 무창층 강화유리 구조, 드라이비트 외벽으로 분석하였다.

퓨즈를 이용한 전기화재의 원인분석에 관한 연구 (A Study on the Causal Analysis of Electrical Fire by Using Fuse)

  • 이춘하;김시국;옥경재
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.24-28
    • /
    • 2008
  • 본 논문은 전기제품 내에 안전장치로 사용되는 퓨즈를 이용한 전기화재의 원인분석에 관한 연구이다. 시료는 유리관퓨즈(정격 15 A, $5{\times}20mm$)와 온도퓨즈(정격 10 A, $72^{\circ}C$)를 사용하였다. 전기화재의 주요원인인 단락 및 과부하 그리고 외부화염을 인위적으로 가하여 소손된 퓨즈의 특성을 비교 분석하였다. 실험결과 유리관퓨즈의 경우 소손된 퓨즈의 외형 및 표면 그리고 조직분석에서 서로 다른 특징들을 확인할 수 있었다. 온도퓨즈의 경우 외부화염실험의 경우에서만 소손된 퓨즈의 외형 및 가동접점의 표면 그리고 조직분석에서 뚜렷한 특징이 나타났다.