• Title/Summary/Keyword: The Times

Search Result 70,675, Processing Time 0.075 seconds

Studies on the Flacherie Virus in the Silkworm, Bombyx mori L. I. Resistance to Flacherie and Ina-flacnerie Virus in the Leading Silkworm Varieties in Korea (가잠의 바이러스성 연화병에 관한 연구 I. 장려품종에 대한 저항성 검정)

  • 김권영;강석권;이재창
    • Journal of Sericultural and Entomological Science
    • /
    • v.20 no.2
    • /
    • pp.32-35
    • /
    • 1978
  • The infectious flacherie viruses are serious diseases in the silkworm, which affects the cocoon crops. However, there is only a few study on this diseases up-to-date in Korea and, in this experiment, the authors investigated the resistance of the silkworm varieties to flacherie and Ina-flacherie viruses by peroral infection. A cross, Hansaeng #1$\times$ Harisaeng #2, showed the highest resistance to the flacherie virus a Mudeung$\times$Geumho showed the lowest resistance among the examined varieties. It seemed that the varietal difference of resistance against Ina-flacherie virus was appeared and Jam117$\times$ Jam118, Gyeongchu$\times$Yeonil, Mudeung$\times$Geumho, Hansaeng#1$\times$Hansaeng#2 and Hansaeng#3 $\times$ Hansaeng #4 showed non susceptibility by peroral infection. However it was shown that Jam115 $\times$Jam116 had the lowest resistance to Ina-flacherie virus.

  • PDF

Distribution of Heterotropic Bacteria and Physico-Chemical Characteristics in the Chagwi-Do Coastal Waters, Jeju Island (제주 차귀도 연안해역의 종속영양세균 분포 및 이화학적 특성)

  • Moon, Young-Gun;Yeo, In-Kyu;Heo, Moon-Soo
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.4
    • /
    • pp.336-341
    • /
    • 2007
  • To investigate the variations of physico-chemical factors and microbial population, in ten stations at water region of coastal area of Chagwi-Do, Nutritive salts, water temperature, transparency, suspended solid, salinity, COD, DO, pH, heterotrophic bacteria, were analysed three times in September, November in 2004 and February in 2005. Heterotrophic bacteria in surface water was $3.5\times10^1\sim1.16\times10^3\;cfu\;mL^{-1}$, $0.4\times10^1\sim5.6\times10^1\;cfu\;mL^{-1}$, $0.4\times10^1\sim7.8\times10^1$ and bottom water counted $4.5\times10^1\sim1.0\times10^3\;cfu\;mL^{-1}$, $1.2\times10^1\sim1.5\times10^2\;cfu\;mL^{-1}$, $0.4\times10^1\sim4.4\times10^1\;cfu\;mL^{-1}$ in September, November 2004 and February 2005, respectively. The dominant species isolated from the coastal area of Chagwi-Do were identified to be Vibrio spp., Pseudoalteromonas spp. Psuedomonas spp, Bacillus spp., Alteromonas spp., Aeromonas spp., Psychrobacter spp., and Flavobacterium spp.

K-Ar dating on granitic rocks from the Eonyang- and the northwestern part of Ulsan-quardrangle, Kyeongsang-nam-do, Korea (한국(韓國) 경상남도(慶尙南道) 언양도폭(彦陽圖幅) 및 북서부(北西部) 울산도폭(蔚山圖幅) 지역산(地域産) 화강암질암(花崗岩質岩)의 K-Ar 연대(年代))

  • Lee, Yoon Jong;Ueda, Yoshio
    • Economic and Environmental Geology
    • /
    • v.9 no.3
    • /
    • pp.127-134
    • /
    • 1976
  • The K-Ar age determined on six granitic rocks samples from the Eonyang- and the northwestern part of Ulsan-quardrangle, Kyeongsang-nam-do, Korea, ranges from $87{\times}10^6$ years to $58{\times}10^6$ years. Three of the samples belong to the upper Cretaceous ($87{\times}10^6-71{\times}10^6years$) and three to the late Cretaceous-early Tertiary ($63{\times}10^6-58{\times}10^6years$) in age. The early Tertiary ages are measured first on the "Younger Granites" in Korea. These two emplacement periods of granitic rocks are representative that the former is correlated to north Kyushu-Seto Inland belt ($95{\times}10^6-75{\times}10^6years$) and the later to Sanin-central Honshu belt ($65{\times}10^6-50{\times}10^6years$), in southwestern Japan.

  • PDF

Effect of Sugars on the Bacterial Spoilage of Ground Meat (당류(糖類)의 첨가(添加)가 육(肉)의 세균성(細菌性) 부패(腐敗)에 미치는 영향(影響))

  • Kim, Oun-Hyun;Kim, Chang-Han
    • Korean Journal of Food Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.217-223
    • /
    • 1979
  • The present study was to investigate the effect of sugars on the psychrophillic spoilage in ground meat. The obtained results were summarized as follows: 1. The minimum pH values for the ground beef containing 2, 5 and 10 % glucose were 5.25, 5.15 and 4.5, respectively. For the ground pork, the respective values were 5.1, 4.45 and 4.1. 2. Total aerobes, coliform, lactic acid bacteria and lactobacillus counts per gram for the control and 2% glucose-contained ground beef after 9 days for storage at $5^{\circ}C$ were $8.3{\times}10^9vs\;6.0{\times}10^7,\;3.5{\times}10^5vs\;2.4{\times}10^3,\;5.8{\times}10^7vs\;4.7{\times}10^6$ and $3.6{\times}10^5vs\;4.2{\times}10^6$ respectively. For the ground pork, the respective values were $1.2{\times}10^{10}vs\;7.8{\times}10^8,\;3.4{\times}10^5vs\;3.1{\times}10^4,\;5.5{\times}10^7vs\;4.5{\times}10^6$ and $3.3{\times}10^5vs\;3.7{\times}10^5$. The glucose-added ground meat showed higher counts than those of the controls only in the case of lactobacillus without any apparent adverse effects. 3. The length of storage time until the depletion of added glucose was 12, 16 and 28 days for the 2, 5 and 10 % glucose contained ground beef and 9, 16 and 30 days for the ground pork, respectively. pH did not start to increase until the added glucose was depleted completely. 4. The addition of glucose extended significantly the average shelf-life of ground beef at refrigeration condition $(5^{\circ}C)$. The extended shelf-life over the control was 7, 9 and 12days for the 2, 5 and 10 % glucose contained ground beef and 8, 10 and 12 days for the respective ground porks. 5. Although the addition of disaccharides (maltose, lactose, saccharose) lowered the pH of ground meat, the extension of shelf-life as seen in glucose treatment was not affected. In fact, the higher the concentration of added disaccharides was, the greater the degree of putrefaction occurred.

  • PDF

New Intra Coding Scheme for High-definition Video Coding (고화질 비디오 부호화를 위한 새로운 화면내 부호화 방법)

  • Heo, Jin;Ho, Yo-Sung
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.5
    • /
    • pp.72-78
    • /
    • 2008
  • Although the H.264 video coding scheme is popular, it is not efficient for high-definition (HD) video coding because the size of its macroblock is relatively small for the HD video resolution. In this paper, we propose a new intra coding scheme based on the enlarged macroblock size. For the luminance component, intra $4{\times}4$ prediction and intra $16{\times}16$ prediction in H.264 are scaled into intra $8{\times}8$ prediction and intra $32{\times}32$ prediction, respectively. For the chrominance components, intra $8{\times}8$ prediction is extended to intra $16{\times}16$ prediction. Along with the $8{\times}8$ basic coding block size, an $8{\times}8$ integer discrete cosine transform (DCT) is used. Experimental results show that the proposed algorithm improves coding efficiency of the intra coding for HD video: PSNR gain by 0.23dB and bit-rate reduction by 5.32% on average.

Bacterial Flora of East China Sea and Yosu Coastal Sea Areas 1. Horizontal Distributions According to Number of Bacteria, Vibrio spp. and Coliform Group (여수연안 및 동중국해의 세균상 1. 일반 세균, Vibrio spp., 대장균군 균수에 따른 수평 분포)

  • JUNG Kyoo-Jin;SHIN Suk-U
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.1
    • /
    • pp.9-16
    • /
    • 1996
  • In order to understand microbial ecosystem in the fast china sea and Yosu coastal sea horizontal distributions of bacterial flora, Vibrio spp., coliform group, temperature, and salinity in this sea area, were studied 42 sampling stations during 6th-l4th August, 1992. From the results, salinity and temperature were $24.64\~33.78\%_{\circ}$ and $22.53\~29.18^{\circ}C$, respectively. As the open sea far from land goes on, salinity became low while temperature became high. Viable cell counts of bacteral flova, Vibrio spp., and roliform group in Yosu coastal sea water were $1.0\times10^2\~3.0\times10^4/ml,\;0.2\times10\~9.0\times10^3/ml,\;and\;0.3\times10\~3.0\times10^3/ml$ while those of these in the open sea water were $0.4\times10\~2.0\times10^3/ml,\;0.8\times10\~3.0\times10/ml,\;and\;0.9\times10\~1.3\times10/ml$, respectively.

  • PDF

Design of Unified HEVC/VP9 4×4 Transform Block (HEVC/VP9 4×4 Transform 통합 블록 설계)

  • Jung, Seulkee;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.19 no.3
    • /
    • pp.392-399
    • /
    • 2015
  • This paper proposes a unified $4{\times}4$ transform architecture for HEVC and VP9 codec to reduce hardware size. It performs HEVC $4{\times}4$ IDCT, HEVC $4{\times}4$ IDST, VP9 $4{\times}4$ IDCT, and VP9 $4{\times}4$ IADST in a unified hardware. HEVC $4{\times}4$ IDCT and VP9 $4{\times}4$ IDCT have same IDCT computation except for the scales of coefficients. Similarly, HEVC $4{\times}4$ IDST and VP9 $4{\times}4$ IADST have same IDST computation except for the scales of coefficients. Furthermore, IDCT and IDST have quite a lot of similarity, so they can share some hardwares in common. So the proposed hardware performs all 4 operations in a unified hardware, where each operation has its own multiplication coefficients with shared butterfly adders. The synthesized block in 0.18 um technology is 6,679 gates, and the gate count is reduced by 25.3% in comparison with conventional designs.

Assessing bioequivalence in 2×3 dual designs (2×3 이중 설계에서 생물학적 동등성 평가)

  • Woo, Hwa Hyoung;Jeong, Gyu Jin;Park, Sang-Gue
    • Journal of the Korean Data and Information Science Society
    • /
    • v.28 no.4
    • /
    • pp.743-754
    • /
    • 2017
  • Assessing bioequivalence between original drug and generic drug is traditionally based on $2{\times}2$ crossover design. As bioequivalence trials for highly variable drugs are getting popular, the required sample size based on $2{\times}2$ crossover design would be very large, which might cause the ethical concerns. Regulatory agencies like EMA and MFDS recommended higher order crossover designs such as $2{\times}4$, $4{\times}2$ and $4{\times}4$ crossover designs. Alternatively, a $2{\times}3$ dual design may be recommended in terms of economical and ethical points of view in comparison with the $2{\times}4$ crossover design for highly variable drug. In this study, we consider some statistical characteristics of $2{\times}3$ dual design and propose statistical procedures for calculating sample size and assessing bioequivalence based on $2{\times}3$ dual design. We also discuss the proposed procedures from the perspective of newly revised bioequivalence guidance issued by MFDS.

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

THE LINEAR DISCREPANCY OF 3 × 3 × 3

  • Chae, Gab-Byoung;Cheong, Min-Seok;Kim, Sang-Mok
    • Communications of the Korean Mathematical Society
    • /
    • v.25 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • $3{\times}3{\times}3$ is the meaningful smallest product of three chains of each size 2n+1 since $1{\times}1{\times}1$ is a 1-element poset. The linear discrepancy of the product of three chains $2n{\times}2n{\times}2n$ is found as $6n^3-2n^2-1$. But the case of the product of three chains $(2n + 1){\times}(2n + 1){\times}(2n + 1)$ is not known yet. In this paper, we determine ld$(3{\times}3{\times}3)$ as a case to determine the linear discrepancy of the product of three chains of each size 2n + 1.