• Title/Summary/Keyword: The Success Rate

Search Result 2,112, Processing Time 0.034 seconds

STABILITY CHANGES OF IMMEDIATELY LOADED AND DELAYED LOADED IMPLANTS IN EDENTULOUS MANDIBLE (하악 무치악에서 즉시하중과 지연하중간 임플랜트의 안정성 변화)

  • Jung, Hye-Eun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.250-262
    • /
    • 2007
  • Statement of problem: It was reported high success rate of implant-supported fixed prostheses using with $5{\sim}6$ implants on anterior mandible. Recently, immediate loading protocol was focused to overcome disadvantages of classic 2-stage delayed loading protocol. Purpose: This clinical study was to evaluate stability changes with time of immediately loaded and delayed loaded implants in edentulous mandible and to compare stability changes with time according to implantation sites. Materials and methods: Five or six implants were placed on anterior mandible depending on the arch shape. The immediately loading group was consisted of 8 patients received their prostheses within $24{\sim}48$ hours after implantation. The delayed loading group was consisted of 8 patients received their definitive prostheses following classical prosthetic procedures after a healing period of 3 months. All patients were recalled every 6 months for check-up. The evaluations of radiographic examination, ISQ value measurement and recording of complication were done. To evaluate marginal bone level, intraoral periapical radiographs were taken with long cone paralleling technique. At every evaluation recall, all prostheses were removed and ISQ values were measured with OsstellTM on individual implants. Results: 1. None of implants was failed. All implants showed stable marginal bone levels and ISQ values. 2. Marginal bone level changes with time showed statistically significant difference between immediately loading group and delayed loading group (P<0.001). 3. ISQ value changes with time did not show statistically significant difference between immediately loading group and delayed loading group (P=0.079). ISQ value decreased with time in both groups, however, all implants showed stable ISQ value at 30 months-recall evaluation. 4. Marginal bone level changes with time did not show statistically significant differences among implantation sites (P=0.604). 5. ISQ value changes with time showed statistically significant differences among implantation sites (P=0.047). ISQ values of most posterior implants decreased with time comparing to other implants. Conclusion: Although the marginal bone level of the terminal abutment didn't different with the other implants, ISQ value of the terminal abutment was lower than that of the other implants. Therefore, further clinical evaluation would be needed in this point of view.

Effect of Temporary Anterior Positioning Splint Using Putty Impression Material on Acute Closed Lock (급성 과두 걸림의 치료에서 퍼티 고무 인상재로 제작한 임시 전방위치장치의 적용)

  • Song, Ji-Hee;Kim, Ji-Hyun;Kwon, Jeong-Seung;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.37 no.4
    • /
    • pp.221-225
    • /
    • 2012
  • Disc dislocation without reduction, as known as closed lock, is a clinical condition in which the disc is dislocated from the condyle and does not return to normal position during condylar movement When the condition of disc dislocation without reduction is acute, the initial therapy should include an attempt to reduce or recapture the disc by manual manipulation. When patients report a history of being locked for 1 week or less, manual manipulation is usually successful. In patients with a longer history, success rate tends to decrease rapidly. If the disc has been successfully recaptured, placing an anterior positioning appliance is recommended to prevent clenching on the posterior teeth, which would likely redislocated the disc. But it is hard to make an appliance immediately in the clinic because it takes too much time. And making an appliance using self-curing acrylic resin is not very popular because of its discomfort by odor and working time. Also, if the patient has resin allergy or is under orthodontic treatment, or if it is impossible to control behavior of the patient, it has been restricted to make an appliance immediately. Therefore, to supplement this disadvantages, we tried to confirm about successful short term use of temporary anterior positioning splint made by using putty impression material after manual manipulation in this study.

Vertical Handover between LTE and Wireless LAN Systems based on Common Radio Resource Management (CRRM) and Generic Link Layer (GLL) (LTE/WLAN 이종망 환경에서 범용링크계층과 통합무선자 원관리 기법이 적용된 VHO 방안 연구)

  • Kim, Tae-Sub;Oh, Ryong;Lee, Sang-Joon;Yoon, Suk-Ho;Ryu, Seung-Wan;Cho, Choong-Ho
    • Journal of Internet Computing and Services
    • /
    • v.11 no.1
    • /
    • pp.35-48
    • /
    • 2010
  • For the next generation mobile communication system, diverse wireless network techniques such as beyond 3G LTE, WiMAX/WiBro, and next generation WLAN etc. are proceeding to the form integrated into the All-IP core network. According to this development, Beyond 3G integrated into heterogeneous wireless access technologies must support the vertical handover and network to be used of several radio networks. However, unified management of each network is demanded since it is individually serviced. Therefore, in order to solve this problem this study is introducing the theory of Common Radio Resource Management (CRRM) based on Generic Link Layer (GLL). This study designs the structure and functions to support the vertical handover and propose the vertical handover algorithm of which policy-based and MCDM are composed between LTE and WLAN systems using GLL and CRRM. Finally, simulation results are presented to show the improved performance over the data throughput, handover success rate and the system service cost.

Percutaneous Transhepatic Treatment of Benign Bile Duct Strictures Using Retrievable Covered Stents: Long-Term Outcomes in 148 Patients

  • Byung Soo Im;Dong Il Gwon;Hee Ho Chu;Jin Hyoung Kim;Gi-Young Ko;Hyun-Ki Yoon
    • Korean Journal of Radiology
    • /
    • v.23 no.9
    • /
    • pp.889-900
    • /
    • 2022
  • Objective: To investigate the long-term outcomes of percutaneous treatment of benign biliary strictures using temporary placement of a retrievable expanded polytetrafluoroethylene (PTFE) covered stent. Materials and Methods: We retrospectively analyzed the outcomes of 148 patients (84 male and 64 female; age range, 11-92 years) who underwent percutaneous transhepatic placement and removal of a retrievable PTFE-covered stent for the treatment of benign biliary strictures between March 2007 and August 2019 through long-term follow-up. Ninety-two patients had treatment-naïve strictures and 56 had recurrent/refractory strictures. Results: Stent placement was technically successful in all 148 patients. The mean indwelling period of the stent was 2.4 months (median period, 2.3 months; range, 0.2-7.7 months). Stent migration, either early or late, occurred in 28 (18.9%) patients. Clinical success, defined as resolution of stricture after completing stent placement and removal, was achieved in 94.2% (131 of 139 patients). The overall complication rate was 15.5% (23 of 148 patients). During the mean follow-up of 60.2 months (median period, 52.7 months; range, 1.6-146.1 months), 37 patients had a recurrence of clinically significant strictures at 0.5-124.5 months after removal of biliary stent and catheter (median, 16.1 months). The primary patency rates at 1, 3, 5, 7, and 10 years after removal of biliary stent and catheter were 88.2%, 70.0%, 66.2%, 60.5%, and 54.5%, respectively. In the multivariable Cox proportional hazard regression analysis, sex, age, underlying disease, relation to surgery, stricture type, biliary stones, history of previous treatment, and stricture site were not significantly associated with the primary patency. Conclusion: Long-term outcomes suggest that percutaneous treatment of benign biliary strictures using temporary placement of retrievable PTFE-covered stents may be a clinically effective method.

Effect of Venture Business Tendency of North Korea Refugee Families on Adaptation to South Korean Society and Family Health (북한이탈주민의 벤처창업 성향이 남한사회 적응성과 가족건강성에 미치는 영향)

  • Choi, Baek Man;Byun, Sang Hae
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.2
    • /
    • pp.69-76
    • /
    • 2015
  • This paper aims to analyze how the Venture Business Tendency of North Korean refugees affects social adaptation and family health, and to provide proposals for policy making on the issue. For the purpose, we specifically suggest analysis of activation plan that 48 Venture Business North Korean managed Enterprise types, Entrepreneur type, Business type, Gender, Profit etc. As a result of analysis of actual proof, First, The Venture Business North Korean refugees managed need to consult to be technology business professionally because they features to be self-employment than expertise and knowledge basis type. Second, the rate of success of North Korean refugees is researched that female is higher than male. Third, to support Venture Business of North Korean refugees, they need one on one incubating support syspen why they are inexperienced in network, technical skills. Fourth, Venture Business Tendency of North Korean refugees affects social adaptation and family health. Since mid 1990's, North Korean refugees have come to South Korea through China or third countries due to collapsing economy of North Korea. In an effort to help those escaping from North Korea, the Seoul government provided them with a 3-month settlement program. But they have had experienced difficulties in communication, cultural assimilation, and confusion in their value system and identity. For the purpose, one-on-one interview was carried out on 45 North Korean refugees living in Seoul and neighboring cities, and the interviewed group was classified into three categories: single households, single-parent families and families with parents. The study findings demonstrated four policy alternatives to help improve quality of life of North Korean refugees and to help their successful settlemen.

  • PDF

Comparative Study on Osseointegration of Calcium Metaphosphate (CMP) Coated Implant to RBM Implant in the Femur of Rabbits (가토의 대퇴부에 Calcium Metaphosphate로 코팅된 임플란트 매식후 골유착에 관한 비교 연구)

  • Kang, Young-Joo;Kim, Ki-Hyun;Lee, Jae-Yeol;Lee, Ju-Min;Ahn, Sang-Wook;Song, Jin-Woo;Jung, Eu-Gene;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.511-520
    • /
    • 2010
  • Purpose: This study was conducted in order to compare the efficacy of osseointegration of three different calcium metaphosphate (CMP) coated implants in the rabbit's femur. Materials and Methods: Twenty four rabbits and three different type of CMP coated implants and RBM implants were used in this study. The animals were divided into 4 groups on the basis of implant surface characteristics. Two implants were installed into the condyle of femur of each rabbits. The animals were sacrificed at 2 and 4 weeks after installation. The undecalcified specimens were prepared for histological, radiological examination and histomorphometric analysis of implant-bone contact ratios (BIC) and bone area ratio (BA). Results: Two implants were failed to osseointegrate and implant success rate was 95.2%. There were not any significant inflammatory response in all groups. Fluorescent image at 4 weeks shows that remodeling is slower in RBM group than CMP group. CMP III showed more active remodeling than CMP I, II. In histomorphologic analysis, BIC ratio at 2 weeks was lower than 4 weeks. Conclusion: The results suggest that the ratios of CMP coated implants were higher than that of RBM control group but there is no significantly difference between RBM group and CMP group. In conclusion, CMP coated implant had more clinical availability than RBM implants.

Key Bit-dependent Attack on Side-Channel Analysis-Resistant Hardware Binary Scalar Multiplication Algorithm using a Single-Trace (부채널 분석에 안전한 하드웨어 이진 스칼라 곱셈 알고리즘에 대한 단일 파형 비밀 키 비트 종속 공격)

  • Sim, Bo-Yeon;Kang, Junki;Han, Dong-Guk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.5
    • /
    • pp.1079-1087
    • /
    • 2018
  • Binary scalar multiplication which is the main operation of elliptic curve cryptography is vulnerable to the side-channel analysis. Especially, it is vulnerable to the side-channel analysis which uses power consumption and electromagnetic emission patterns. Thus, various countermeasures have been studied. However, they have focused on eliminating patterns of data dependent branches, statistical characteristic according to intermediate values, or the interrelationships between data. No countermeasure have been taken into account for the secure design of the key bit check phase, although the secret scalar bits are directly loaded during that phase. Therefore, in this paper, we demonstrate that we can extract secret scalar bits with 100% success rate using a single power or a single electromagnetic trace by performing key bit-dependent attack on hardware implementation of binary scalar multiplication algorithm. Experiments are focused on the $Montgomery-L{\acute{o}}pez-Dahab$ ladder algorithm protected by scalar randomization. Our attack does not require sophisticated pre-processing and can defeat existing countermeasures using a single-trace. As a result, we propose a countermeasure and suggest that it should be applied.

Reference values for respiratory system impedance using impulse oscillometry in healthy preschool children

  • Park, Jye-Hae;Yoon, Jung-Won;Shin, Youn-Ho;Jee, Hye-Mi;Wee, Young-Sun;Chang, Sun-Jung;Sim, Jung-Hwa;Yum, Hye-Yung;Han, Man-Yong
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.2
    • /
    • pp.64-68
    • /
    • 2011
  • Purpose: The normal values for lung resistance and lung capacity of children, as determined by impulse oscillometry (IOS), are different for children of different ethnicities. However, reference values there is no available reference value for Korean preschool children have yet to be determined. The aim of the present study was to determine the normal ranges of IOS parameters in Korean preschool children. Methods: A total of 133 healthy Korean preschool children were selected from 639 children (aged 3 to 6 years) who attended kindergarten in Seongnam, Gyeonggi province, Korea. Healthy children were defined according to the European Respiratory Society (ERS) criteria. All subjects underwent lung function tests using IOS. The relationships between IOS value (respiratory resistance (Rrs) and reactance (Xrs) at 5 and 10 Hz and resonance frequency (RF)) and age, height, and weight were analyzed by simple linear and multiple linear regression analyses. Results: The IOS success rate was 89.5%, yielding data on 119 children. Linear regression identified height as the best predictor of Rrs and Xrs. Using stepwise multiple linear regressions based on age, height, and weight, we determined regression equations and coefficients of determination ($R^2$) for boys ($Rrs_5=1.934-0.009{\times}Height$, $R^2$=12.1%; $Xrs_5=0.774+0.006{\times}Height-0.002{\times}Age$, $R^2$=20.2% and for girls $(Rrs_5=2.201-0.012{\times}Height$, $R^2$=18.2%; $Xrs_5=-0.674+0.004{\times}Height$, $R^2$=10.5%). Conclusion: This study provides reference values for IOS measurements of normal Korean preschool children. These provide a basis for the diagnosis and monitoring of preschool children with a variety of respiratory diseases.

Implementation of the ZigBee-based Homenetwork security system using neighbor detection and ACL (이웃탐지와 ACL을 이용한 ZigBee 기반의 홈네트워크 보안 시스템 구현)

  • Park, Hyun-Moon;Park, Soo-Hyun;Seo, Hae-Moon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.46 no.1
    • /
    • pp.35-45
    • /
    • 2009
  • In an open environment such as Home Network, ZigBee Cluster comprising a plurality of Ato-cells is required to provide intense security over the movement of collected, measured data. Against this setting, various security issues are currently under discussion concerning master key control policies, Access Control List (ACL), and device sources, which all involve authentication between ZigBee devices. A variety of authentication methods including Hash Chain Method, token-key method, and public key infrastructure, have been previously studied, and some of them have been reflected in standard methods. In this context, this paper aims to explore whether a new method for searching for neighboring devices in order to detect device replications and Sybil attacks can be applied and extended to the field of security. The neighbor detection applied method is a method of authentication in which ACL information of new devices and that of neighbor devices are included and compared, using information on peripheral devices. Accordingly, this new method is designed to implement detection of malicious device attacks such as Sybil attacks and device replications as well as prevention of hacking. In addition, in reference to ITU-T SG17 and ZigBee Pro, the home network equipment, configured to classify the labels and rules into four categories including user's access rights, time, date, and day, is implemented. In closing, the results demonstrates that the proposed method performs significantly well compared to other existing methods in detecting malicious devices in terms of success rate and time taken.

Production of Transgenic Porcine haboring the Human Erythropoietin(EPO) Gene (사람 조혈인자 유전자(Human Erythropoietin Gene)를 도입한 형질전환돼지 생산)

  • 이연근;박진기;민관식;이창현;성환후;전익수;임석기;양병철;임기순
    • Korean Journal of Animal Reproduction
    • /
    • v.26 no.2
    • /
    • pp.95-104
    • /
    • 2002
  • This study was performed during the four seasons for the production of transgenic pigs containing the human erythropoietin(hEPO) transgene. Purebred Landrace gilts and sows approximately 8∼15 months of age (n=42) were used fur the collection of 1-cell zygotes for DNA microinjection and transfer. Retrospectively, estrus synchronization and superovulation schemes were evaluated to assess practicality for zygote collection. Synchronization and superovulation procedures were used that cyclic gilts were synchronized with 20mg altrenogest (ALT) per day for 9days after PG600 administration followed by superovulation with 1500IU pregnant mares serum gonadotropin (PMSG) and 500IU human chorionic gonadotrophin (hCG). Preparation of recombinant gene for microinjection is mice whey acidic protein promoter (mWAP) linked to human erythropoietin (hEPO) gene. After hormone treatment, 650 embryos were collected from 23 donors and 83.1% (540/650) embryos were in 1-cell stage which can be visualized the pronuclei for DNA microinjection. A total of 543 DNA microinjected embryos fiom donors were transferred to 19 synchronized recipients, seven of them maintained pregnancy and delivered 47 piglets. One of the 47 offsprings were determined to have transgene by PCR analysis. The overall rate of transgenic production was 2.13% (tansgenic/offspring). This study provides the success and useful information regarding production of transgenic pig for bioreactor research.