• Title/Summary/Keyword: The Maximum Wind Speed

검색결과 593건 처리시간 0.027초

A Review on the Building Wind Impact through On-site Monitoring in Haeundae Marine City: 2021 12th Typhoon OMAIS Case Study

  • Kim, Jongyeong;Kang, Byeonggug;Kwon, Yongju;Lee, Seungbi;Kwon, Soonchul
    • 한국해양공학회지
    • /
    • 제35권6호
    • /
    • pp.414-425
    • /
    • 2021
  • Overcrowding of high-rise buildings in urban zones change the airflow pattern in the surrounding areas. This causes building wind, which adversely affects the wind environment. Building wind can generate more serious social damage under extreme weather conditions such as typhoons. In this study, to analyze the wind speed and wind speed ratio quantitatively, we installed five anemometers in Haeundae, where high-rise buildings are dense, and conducted on-site monitoring in the event of typhoon OMAIS to determine the characteristics of wind over skyscraper towers surround the other buildings. At point M-2, where the strongest wind speed was measured, the maximum average wind speed in 1 min was observed to be 28.99 m/s, which was 1.7 times stronger than that at the ocean observatory, of 17.0 m/s, at the same time. Furthermore, when the wind speed at the ocean observatory was 8.2 m/s, a strong wind speed of 24 m/s was blowing at point M-2, and the wind speed ratio compared to that at the ocean observatory was 2.92. It is judged that winds 2-3 times stronger than those at the surrounding areas can be induced under certain conditions due to the building wind effect. To verify the degree of wind speed, we introduced the Beaufort wind scale. The Beaufort numbers of wind speed data for the ocean observatory were mostly distributed from 2 to 6, and the maximum value was 8; however, for the observation point, values from 9 to 11 were observed. Through this study, it was possible to determine the characteristics of the wind environment in the area around high-rise buildings due to the building wind effect.

Comparison of MPPT Based on Fuzzy Logic Controls for PMSG

  • Putri, Adinda Ihsani;Choi, Jaeho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 추계학술대회
    • /
    • pp.285-286
    • /
    • 2011
  • Maximum Power Point Tracker (MPPT) is the big issue in generating power based on Wind Energy Conversion System. In case of unknown turbine characteristic, it is useful to implement MPPT based on fuzzy logic control. This kind of control is able to find the value of duty cycle to meet maximum power point at particular wind speed. There are many methods to develop MPPT based fuzzy logic controls. In this paper, two of the methods are compared both at low and high fluctuating wind speed.

  • PDF

풍력발전의 최대전력점 추종제어 방법에 관한 연구 (A study on the Maximum Power Point Tracking Control System of Wind Power Generation)

  • 고석철;이재;임성훈;강형곤;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking (MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

풍력발전의 최대전력점 추종제어 방법에 관한 연구 (A study on the Maximum Power Point Tracking Control System of Wind Power Generation)

  • 고석철;이재;임성훈;강형곤;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.153-156
    • /
    • 2001
  • Maximum Power Point Tracking(MPPT) Is used in wind power generation systems to maximize wind power turbin output power, irrespective of wind speed conditions and of the load electrical characteristics. In this paper we do the equivalent modeling the mechanical energy of wind power turbine according to wind speed into the synchronous generator. We analyse the equivalent modeling output part of rectifier into DC/DC converter input part theoretically. We design a control algorithm for variable voltage according to wind speed intensity and density so that load voltage of chopper is controlled steadily using the maximum power point tracking(MPPT) control method. We analyse a battery charging characteristics and a charging circuit for power storage enabling the supply of stable power to the load. We design a system and do the modeling of it analytically so that it supplies a stable power to the load by constructing a DC-AC inverter point. Also we design a charging circuit usable in actual wind power generation system of 30kW and confirm its validity.

  • PDF

우리 나라의 바람 일변동 특성 (Characteristics of Diurnal Variation of Wind over the South Korean)

  • 송봉근;김영섭;이동인;한영호
    • 한국환경과학회지
    • /
    • 제9권6호
    • /
    • pp.475-482
    • /
    • 2000
  • The purpose of this study is to find out the temporal and spatial characteristics of the diurnal wind variation between coastal and inland areas using the hourly wind data of 58 AWS-stations in the South Korea which are collected during the 10 years from 1980. Diurnal variation is investigated by using the Fast Fourier Transform(FFT), and the wind direction in investigated by comparing C(sub)r with C(sub)v represented the constancy of wind. For the scalar wind speed, the maximum wind speed occurs in the daytime 14h to 16h. The maximum diurnal amplitude at coastal areas occurs from 12h to 16h, and is about 2 hours faster than that at inland areas. Vector mean wind speed is strong at coastal areas and Chupungnyong, Kumi, Taegu of inland areas. The diurnal variation ellipses make a right angle with coastline show that the land and sea breezes are prevailing. The constancy of wind is strong at all observations in January. In the relationship between $C_r and C_v, C_v is higher than C_r$.

  • PDF

한국에서 풍속 변화에 관한 연구 -1월과 8월을 대상으로- (A Study on the Change of Wind Speed in South Korea: In Case of January and August)

  • 이승호
    • 대한지리학회지
    • /
    • 제47권3호
    • /
    • pp.347-358
    • /
    • 2012
  • 이 연구에서는 겨울과 여름철의 풍속변화를 파악하기 위하여 남한 13개 지점의 1961년부터 2010년까지 1월과 8월의 평균풍속과 최대풍속, 강풍일수, 폭풍일수를 분석하였다. 평균풍속과 최대풍속은 1월과 8월에 해안에 위치한 부산, 제주, 울산, 포항에서 비교적 큰 폭으로 감속하였다. 강풍일수와 폭풍일수도 해안에 위치한 지점에서 감소한 경향이다. 1월 풍속이 크게 감소한 지점에서 풍속과 평균기온 사이에 비교적 높은 음의 상관관계가 있는 반면, 8월에는 두 변수 간의 상관관계가 낮다. 또한 강풍일(평균풍속 5m/sec 이상일)과 폭풍일(일 최대풍속 13.9m/sec 이상일)의 빈도가 비교적 높은 지점에서는 1월평균기온과 1월의 강풍일 및 폭풍일수 사이에 비교적 높은 음의 상관관계가 있다. 이는 1월의 바람 특성이 기온상승에 따라 바뀔 수 있다는 것을 시사한다.

  • PDF

Smooth Wind Power Fluctuation Based on Battery Energy Storage System for Wind Farm

  • Wei, Zhang;Moon, Byung Young;Joo, Young Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2134-2141
    • /
    • 2014
  • This paper addresses on a wind power system with BESS(Battery Energy Storage System). The concerned system consists of four parts: the wind speed production model, the wind turbine model, configure capacity of the battery energy storage, battery model and control of the BESS. First of all, we produce wind speed by 4-component composite wind speed model. Secondly, the maximum available wind power is determined by analyzing the produced wind speed and the characteristic curve of wind power. Thirdly, we configure capacity of the BESS according to wind speed and characteristic curve of wind speed-power. Then, we propose a control strategy to track the power reference. Finally, some simulations have been demonstrated to visualize the feasibility of the proposed methodology.

소형 직접구동형 풍력발전기의 최대 출력제어 (Maximum Power Control of Small Direct-Drive Wind Power Generator)

  • 김철호;이우석;서영택;오철수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.875-877
    • /
    • 2004
  • Research related to renewable energy is urgently required to cope with the depletion of fossil fuel and the environmental pollution. This paper deals with maximum power control of 1kW rating wind power generator. To implement direct-drive generator, axial flux permanent magnet generator is adopted to test the converter. The blade is attached to the surface of outer rotor disk. Generally wind power generator is operated under the rated wind speed. To capture maximum power at my given wind speed, the coordination of generator and converter is essential. Buck/Boost converter is designed to charge 24V battery and under the low wind speed it operates as boost converter.

  • PDF

강원 영동지역 봄철 산불대형화 영향 기상요소 분석 (A Study on Meteorological Elements Effecting on Large-scale Forest Fire during Spring Time in Gangwon Young-dong Region)

  • 이시영;김지은
    • 한국방재학회 논문집
    • /
    • 제11권1호
    • /
    • pp.37-43
    • /
    • 2011
  • 봄철은 강수량이 연평균의 13% 정도로 적어 건조한 계절이며, 영동지역에 대형 산불이 많이 발생했던 해는 풍속은 강하고 공중습도가 봄철 평균보다도 낮고 강수량도 상대적으로 적어 더욱 건조했다. 대형산불이 발생했던 날은 평균풍속, 최대풍속, 최대순간풍속이 5.9 m/s, 11.3 m/s, 20.9 m/s로 산불 발생일의 평균값보다 1.8 m/s, 3.0 m/s, 6.9 m/s 크게 나타나, 산불의 대형화와 기상요소는 밀접한 관계를 나타냈다.

다변풍속 적응형 Darrieus-Sauonius 초합 수직푹 풍력발전 시스템의 설계 (A design of vertical axis wind power generating system combined with Darrieus-Savonius for adaptation of variable wind speed)

  • 서영택;오철수
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.185-192
    • /
    • 1996
  • This paper presents a design of vertical axis Darrieus wind turbine combine with Savonius for wind-power generating system to be adapted for variable wind speed. The wind turbine consists of two troposkien- and four Savonius-blades. Darrieus turbine is designed with diameter 9.4[m], chord length 380[mm], tip speed ratio 5. Savonius turbine is designed with diameter 1.8[m], height 2[m], tip speed ratio 0.95. The design of turbine is laid for the main data of rated wind speed 10[m/s], turbine speed 101.4[rpm]. The generating power is estimated to maximum power 20[kW], and this is converted to commercial power line by means of three phase synchronous generator-inverter system. Generating system is designed for operation on VSVF(variable speed variable frequency) condition and constant voltage system.

  • PDF