• Title/Summary/Keyword: The Environmental Test

Search Result 10,359, Processing Time 0.044 seconds

Statistical Study on the Measurement Assurance Program in Environmental Pollution Measurement Activities -The Round-Robin Test about Water Pollution- (水質汚染物質의 共同試料分析調査)

  • 李載昌;申漢豊;李樂榮
    • Journal of the Korean Statistical Society
    • /
    • v.9 no.2
    • /
    • pp.194-212
    • /
    • 1980
  • This report describes a preliminary study necessary to implement Measurement Assurance Program (MAP). The purpose of the study is to improve the measurement reliability of the laboratories which take environmental pollution measurement. We carried out the interlaboratory test or "Round-Robin" test program in which seven laboratories participated in order to obtain more reliable data about water pollution.pollution.

  • PDF

A Study on the Reliability(Environmental) Test Trend in Korea Electronic Industries (국내 전자부품 중소기업의 신뢰성 시험 활용현황 및 지원방향)

  • Kang, Bo-Chul;Cho, Jai-Rip
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2007.04a
    • /
    • pp.331-333
    • /
    • 2007
  • Product reliability is important to quality and competitiveness. Much management and engineering efforts go into evaluating reliability, assessing new designs and changes of manufacturing processes, identifying cause of failure. Major methods are based on environmental test. In this study, we analysis the environmental test data of the electrical component, unit, set. These data were gathered for 7 years.

  • PDF

Noise Test and Evaluation of a 750kW Wind Turbine Generator (750kW 풍력발전기의 소음실증)

  • Kim, Seock-Hyun;Heo, Wook;Lee, Hyun-Woo
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.59-64
    • /
    • 2007
  • This study introduces an environmental noise evaluation procedure and results for a wind turbine (W/T) system. Test and evaluation are required by the international standard IEC 61400-11 in the aspect of environmental effect. Test and evaluation are performed on U-50 WT model which is first developed by the domestic W/T manufacturer. W/T test model is under operation in Daekwanryung wind test site. An integrated monitoring system in the test site is utilized for the evaluation. With the noise signal, meteorological data and W/T operational data are monitored in real time by the integrated monitoring system using LabVIEW. From the measured noise data, acoustic power level are estimated and compared with those of other similar size WT under the wind speeds required by international standard.

  • PDF

A Study on an Environmental Test Sequence for Electrical Units on Aircraft (항공기 전장품의 환경시험순서에 관한 연구)

  • Yang, Jung Ho;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.2
    • /
    • pp.114-121
    • /
    • 2014
  • An environmental test has been performed in order to improve the lifetime and reliability of the electrical units on aircraft. However, faults occurring in the field of aircraft have been difficult to predict and prevent, and new concepts for reliability testing are desired. Therefore, a composite reliability test sequence was proposed in the conventional studies. This study introduces test sequence guidelines based on relevant principles and considerations for electronic testing according to International Standard IEC-60068-1 and the United States Military Standard MIL-STD-810G. In addition, we analyze possible causes of failure using two-step QFD based on aircraft operation scenarios. Finally, the proposed test sequence can reproduce various and realistic failure modes for electrical units on aircraft.

The Clothing Consumption Behavior of Fast Fashion Purchaser according to Environmental Consciousness (환경의식에 따른 패스트패션 구매자의 의복소비행동에 관한 연구)

  • Lee, Hyun Ji
    • Fashion & Textile Research Journal
    • /
    • v.17 no.4
    • /
    • pp.550-560
    • /
    • 2015
  • This study investigates clothing consumption behavior of fast fashion purchasers according to environmental consciousness. Questionnaire examined 245 males and females in Busan who experienced fast fashion product purchases. Data were analyzed using factor analysis, t-test. ANOVA, Duncan Test and ${\chi}^{2}-test$. The results are as follows. First, the result showed significant differences in environmental consciousness education according to demographic characteristics. Second, the results showed significant differences in the hedonic pursuit of purchase motivation for fast fashion products according to environmental consciousness. The low environmental awareness group pursued hedonic purchases towards the purchase motivation of fast fashion products. The results showed significant differences in fast fashion disposal behavior according to environmental consciousness; however, not for the disposal motivation of fast fashion. In the disposal behavior of fast fashion, the high environmental awareness group indicated social friendly disposal and the middle environmental awareness group indicated economical disposal. The result showed significant gender differences towards clothing consumption behavior of fast fashion according to demographic characteristics. Males and females showed significant differences in all purchase motivation factor for fast fashion products. They also showed significant differences in economical disposal towards fast fashion disposal behavior.

Acute Toxicity Test of Agricultural Chemicals to Water Fleas (물벼룩을 이용한 농약의 급성 독성에 관한 연구)

  • Lee, Chan-Won;Ryu, Jae-Young;Lim, Kyeong-Won
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.55-63
    • /
    • 2007
  • There are concerns that chemical residues could harm the consumer on the environment, although 50 to 80% of the crops would be destroyed by pests and others without agrochemicals. Environmental fate and ecotoxicity studies are usually carried out to assess the impact on the human and the environment. A comparision of the Daphnia magnia and Simocephalus mixtus toxicity was performed to study the relative sensitivities and discrimination abilities to agriculture chemicals. The species of Simocephalus mixtus was more sensitive to agriculture chemicals than Daphnia magnia. Simocephalus mixtus was approved to be a water flea in determining insecticide and pesticide toxicity by heart-beat rate in a consistency and repeatability. The order of acute toxicity to water flea Daphnia magnia for ecotoxicity test was carbaryl>benomyl>amtirole with both Daphnia magnia and Simocephalus mixtus. The heartbeat pattern after the exposure to agrochemicals was different from that of exposure to heavy metals. Agrochemical leathal concentration test with heartbeat rate measurement was found to be more appropriate than inhibition concentration test with respect to toxicological endpoint.

Toxicity Assessment of PFOA and PFOS Using Freshwater Flea Hyalella azteca (담수산 물벼룩인 Moina macrocopa를 이용한 과불화화합물 PFOA와 PFOS의 독성평가)

  • Lee, Chul-Woo;Kim, Hyun-Mi;Choi, Kyung-Hee
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.3
    • /
    • pp.271-277
    • /
    • 2007
  • Perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS) are fully flurorinated organic compounds which are highly persistent in environment and accumulated in organism. These chemicals are released to the environment at their manufacture, during their use in industrial and consumer applications and from disposal after their use. The purpose of this study was to determine the effects of PFOA and PFOS on the freshwater flea (Moina macrocopa). Acute toxicity test and chronic toxicity test were performed for 2 days and 10 days, respectively. Acute toxicity was assessed on the basis of mortality, while chronic toxicity was assessed by fecundity as well as mortality. The acute toxicity studies on PFOA and PFOS showed that the values of $LC_{50}$ were $73.9\;mg/L\;and\;27.7\;mg/L$ respectively. In the chronic toxicity test, fecundity was reduced significantly at 24.1 mg/L of PFOA and 9.3 mg/L of PFOS, respectively. Conclusively, the results of this work suggest that Moina macrocopa could be a suitable model organism for screening and assessing of environmental pollutants in water.

Measurement of Ordinary Heterotrophic Organism Active Biomass in Activated Sludge Mixed Liquor: Evaluation and Comparison of the Quantifying Techniques

  • Lee, Byung Joon;Wentzel, Mark;Ekama, George;Choi, Yun Young;Choi, Jung Woo
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.91-99
    • /
    • 2014
  • Ordinary heterotrophic organism (OHO) active biomass plays key roles in biological wastewater treatment processes. However, due to the lack of measurement techniques, the OHO active biomass exists hypothetically within the design and simulation of biological wastewater treatment processes. This research was purposed to develop a quick and easy quantifying technique for the OHO active biomass applying a modified batch aerobic growth test. Two nitrification-denitrification activated sludge systems, with 10- and 20-day sludge ages, were operated to provide well-cultured mixed liquor to the batch tests. A steady state design model was firstly applied to quantify the "theoretical" OHO active biomass concentration of the two parent systems. The mixed liquor from the parent systems was then inoculated to a batch growth test and a batch digestion test to estimate the "measured" OHO active biomass concentration in the mixed liquor. The measured OHO active biomass concentrations with the batch growth test and the batch digestion test were compared to the theoretical concentrations of the parent system. The measured concentrations with the batch growth test were generally smaller than the theoretical concentrations. However, the measured concentrations with the batch aerobic digestion tests showed a good correlation to the theoretical concentrations. Thus, a different microbial growth condition (i.e., a higher food/biomass ratio) in the batch growth test, compared to the parent system or the batch digestion test, was found to cause underestimation of the OHO active biomass concentrations.

Nonlinear creep model based on shear creep test of granite

  • Hu, Bin;Wei, Er-Jian;Li, Jing;Zhu, Xin;Tian, Kun-Yun;Cui, Kai
    • Geomechanics and Engineering
    • /
    • v.27 no.5
    • /
    • pp.527-535
    • /
    • 2021
  • The creep characteristics of rock is of great significance for the study of long-term stability of engineering, so it is necessary to carry out indoor creep test and creep model of rock. First of all, in different water-bearing state and different positive pressure conditions, the granite is graded loaded to conduct indoor shear creep test. Through the test, the shear creep characteristics of granite are obtained. According to the test results, the stress-strain isochronous curve is obtained, and then the long-term strength of granite under different conditions is determined. Then, the fractional-order calculus software element is introduced, and it is connected in series with the spring element and the nonlinear viscoplastic body considering the creep acceleration start time to form a nonlinear viscoplastic creep model with fewer elements and fewer parameters. Finally, based on the shear creep test data of granite, using the nonlinear curve fitting of Origin software and Levenberg-Marquardt optimization algorithm, the parameter fitting and comparative analysis of the nonlinear creep model are carried out. The results show that the test data and the model curve have a high degree of fitting, which further explains the rationality and applicability of the established nonlinear visco-elastoplastic creep model. The research in this paper can provide certain reference significance and reference value for the study of nonlinear creep model of rock in the future.

Environmental Test of Avionics Equipment for Lightning Indirect Effect (낙뢰 간접영향에 대한 항공전자장비의 환경시험)

  • Jeong, Duck-young;Yang, Hyun-duck
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.2
    • /
    • pp.55-59
    • /
    • 2013
  • Before avionics equipment are installed in aircraft, several environmental tests such as temperature, vibration, lightning, fire etc. must be conducted. One of the environmental tests is to substantiate protection designs of lightning indirect effect. It can be showed through RTCA DO-160G, section22 "Lightning Induced Transient Susceptibility" test. An additional test of aircraft level is required as well after installation of avionics equipment.