• Title/Summary/Keyword: The Configuration of the zone

Search Result 143, Processing Time 0.025 seconds

Experimental investigations on seismic response of riser in touchdown zone

  • Dai, Yunyun;Zhou, Jing
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.3
    • /
    • pp.348-359
    • /
    • 2018
  • A series of indoor simulation tests on a large-sized shaking table was performed, which was used to simulate the earthquake ground motion for the pipe-soil interaction system to be tested. The purpose of this study is to examine the dynamic characteristic and seismic response of a length of PVC pipeline lay on a clay seabed under seismic load. The pipeline was fully instrumented to provide strain and acceleration responses in both transverse and in-line. Dynamical modal tests show that corresponding mode shapes vertically and horizontally are basically the same. But the absolute values of the natural frequencies vertically are all higher than those corresponding values in transverse. It turned out that the geometry configuration of riser affects its stiffness. Seismic response of pipeline depends significantly on the waveform, and Peak Ground Acceleration (PGA). As the seismic loading progressed, the strain response was severe around both TDZ and catenary zone. Additionally, strain responses in top and bottom positions were more severe than the result in left or right side of the pipeline in the same section.

Microstructures and Mechanical Properties of Friction Stir Welded High Strength Steels far Shipbuilding (선급용 고장력강 FSW접합부의 미세조직 및 기계적 성질)

  • 장웅성;최기용
    • Journal of Welding and Joining
    • /
    • v.20 no.3
    • /
    • pp.67-73
    • /
    • 2002
  • In an attempt to evaluate the feasibility of friction stir welding(FSW) for joining carbon steels, microstructures and mechanical properties of friction stir welded carbon steels with different grain structures were investigated. In comparison of O-type stir zone(SZ) appeared in various aluminium alloys, configuration of SZ in friction stir welded carbon steels displayed U-type. Plastically deformed pearlite band structure was identified to surround the SZ, indicating the existence of so-called thermo-mechanically affected zone(TMAZ). However, the TMAZ of carbon steels was much narrower than that of Al alloys. The microstructures of both stir zone and TMAZ revealed bainite matrix in a conventional carbon steel for shipbuilding, while, in the same region, ferrite matrix microstructures were formed in a low carbon fine grained steel. The conventional carbon steel showed superior stirring workability to that of the fine grained carbon steel. The yield and tensile strength of the friction stir welded joints were comparable to those of the base metals, and the elongation in welded joints demonstrated excellent ductility. Absorbed energy in SZ of the fine grained carbon steel was ten times higher than that obtained from conventional submerged arc weld metal of the same steel. Based on these results, the application FSW to carbon steels was found to be feasible.

A study on an Infrastructure for Virus Protection (바이러스 차단 인프라 구조에 관한 연구)

  • Noh, Si-Choon;Kim, Su-Hee;J. Kim, Kui-Nam
    • Convergence Security Journal
    • /
    • v.5 no.1
    • /
    • pp.53-62
    • /
    • 2005
  • Virus protection infrastructure managementis network infrastructure management, traffic route management, virus protection zone expansion, and virus protection management for gateway area. This research paper provides a diagnosis of characteristics and weaknesses of the structure of existing virus protection infrastructure, and recommends an improved multi-level virus protection infrastructure as a measure for correcting these weaknesses. Improved virus protection infrastructure filters unnecessary mail at the gateway stage to reduce the load on server. As a result, numberof transmission accumulation decreases due to the reduction in the CPU load on the Virus wall and increase in virus treatment rate.

  • PDF

An Elimination Type Two-Stage Selection Procedure for Gamma Populations

  • Lee, Seung-Ho;Choi, Kook Lyeol
    • Journal of Korean Society for Quality Management
    • /
    • v.13 no.2
    • /
    • pp.29-36
    • /
    • 1985
  • The problem of selecting the gamma population with the largest mean out of k gamma populations, each of which has the same shape parameter is considered. An elimination type two-stage procedure is proposed which guarantees the same probability requirement using the indifference-zone approach as does the single-stage procedure of Gibbons, Olkin and Sobel (1977). The two-stage procedure has the highly desirable property that the expected total number of observations required by the procedure is always less than that of the corresponding single-stage procedure regardless of the configuration of the population parameters.

  • PDF

A Comparative Study of Fine Structure of Callus Cells in Panax ginseng (인삼(人蔘) Callus세포(細胞)의 미세구조적(微細構造的) 비교(比較) 연구(硏究))

  • Lee, Chai-Doo;Lee, Kyu-Bae
    • Applied Microscopy
    • /
    • v.8 no.1
    • /
    • pp.67-76
    • /
    • 1978
  • A comparative investigation of fine structure of callus cells derived from tissue culture of Panax ginseng was made by electron microscope. Callus was consisted of large superficial cells and small inner zone cells derived from shoot apex tissue cultured for 16 weeks. Large superficial cells were contained the clusters of starch grains surrounded by a double plastid membrane. Especially, electron dense particles were deposited just inside and outside of plastid membrane and also deposited on mitochondria-like and endoplasmic reticulum-like structures. Crystalline body was also found in superficial cells. Small inner zone cells were characterized by presence of proplastids sheathed by short endoplasmic reticulum profiles. presence of spiral configuration of ribosomes and absence of crystalline body. Organ primordia was consisted of a dense cytoplasm and notable nucleate cells derived from nodal tissue cultured for 67 weeks. Proplastids containing starch grains and crystalline bodies were frequently observed; starch grains are of small quantity and does not form the clusters as in inner zone cells; hexagonal crystalline body itself does not have always limiting membrane. Remarkably. in a few cells of primordia, particles resembling the presumptive virus were observed mainly in condensed nuclear chromatin and also in cytoplasm, in mitochondrion-like organelle.

  • PDF

A study on Utilization of Dancing Light through Zone Lighting of the Indoor Proscenium Stage (실내 프로시니엄 공연무대의 구역 디자인 구역조명을 통한 무용 조명 활용방법에 관한 연구)

  • Lee, Jang-Weon;Han, Me-Hui
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.1
    • /
    • pp.43-53
    • /
    • 2009
  • This study is to investigate the utilization of Indoor Proscenium Stage Zone Lighting method in the dancing performance. In other words, it is about how we can utilize the principle of zone lighting in dancing performance, a kind of stage art. Stage lights give lights on the stage. Therefore they play big and important roles in dancing performances. Lightings make big influence on the overall atvosphere and situations of the dancing work but most of dancers do not perceive their importance and furthermore they don't know about the lightings very well. To let them know about stage lightings better, we studied lightings form the perspective of the dancers who face the lightings without great knowledge thresh the articles and literature related general lightings and lighting design, books related to stage lightings and dancing lightings, previous studies and academic articles. The most important part of this study is to understand and utilize the principle of zone lightiing. Zone lighting is generally called as cross lighting, which means single light from the crossed two lights. When looking into the principle of the zone lighting of the Indoor Proscenium Stage, it means 45 degree lighting from both sides of the top form the point of the dancer When more than two lights are used, the angle of the light should be $90^{\circ}$or 120. It is the principle of the lighting technology showing the face and body of the dancers ing three dimension. Applying for the principle of this zone lighting to the dancing performance of Indoor Proscenium Stage, the lighting methods and the usage of the lightings were studied. As shown above, the role of the lighting is very important in dancing configuration. We hope that the perception on the dancing lighting will be changed and studies on the dancing lightings. By understanding and applying more principles of lighting, we will make efforts to make better dancing performance and dancing conporsers and dancers shall make more efforts and studies on lighting for better works. Through such efforts, we can have more experts and professionals In dancing lighting field and they will help us to describe and express the intention of the dancing work better as dancing artists. We hope that there will be better quality performances through more and diversified studies in this field.

Electrical Resistivity Survey in the Eon-Yang Fault Area, Southeastern Korean Peninsula (경상분지(慶尙盆地) 언양단층(彦陽斷層) 지역(地域)에 대(對)한 전기비저항(電氣比抵抗) 탐사연구(探査硏究))

  • Kim, In-Soo;Kim, Jong-Yeol
    • Economic and Environmental Geology
    • /
    • v.16 no.1
    • /
    • pp.11-18
    • /
    • 1983
  • Gyeongsang Basin in the southeastern part of the Korean peninsular is characterized by many fault systems. To decipher the geotectonical evolution of the Korean peninsular and marginal basins in her adjacent areas it is prerequisite to understand the spatial distribution pattern and mutual relationships of these fault systems. Because of difficulties in finding any criterion to recognize the faults in field, their extension and mutual relationships in ages are not very clear yet. As an attempt to find geophysical criteria to recognize the fault, geoelectrical resistivity survey was carried out in this study. With the Wenner configuration four resistivity soundings and twenty seven resistivity profilings were done. The electrode distance used was up to 50m. From the results of the resistivity soundings and boring data of earlier groundwater investigations the depth of alluvial and weathered zone was established to be at most 20m in the study area. In the resistivity profiling low resistivity anomaly zones are detected on every traverse, which are interpreted as caused by fractures, fault clays and mylonites in the fault zone. The width of the fault zone amounts to 0.3-1km. By correlating and connecting the negative anomaly zones from traverse to traverse one can determine the trend of th of the faultzone and therefore that of fault itself. The recognized fault trend in this way was $N15^{\circ}-20^{\circ}E$ and this coincides with the direction of the inferred fault line from earlier geological surface mapping. With the help of this characteristical negative anomaly the existance of another $N80^{\circ}W$ trending fault was estabished. This study has shown that geoelectrical resistivity survey can be applied successfully to the problem of tracing fault line insofar as a fault zone has been developed along fault line.

  • PDF

Numerical Study of Contaminant Pathway based on Generic-scenarios and Contaminant-based Scenarios of Vadose Zone (범용 시나리오 및 오염물질 시나리오에 기반한 불포화대 오염물질 경로에 대한 수치모의 연구)

  • Chang, Sun Woo;Kim, Min-Gyu;Chung, Il-Moon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.751-758
    • /
    • 2019
  • This study tested various assumptions that simplified the configuration of the numerical model for unsaturated zone's contaminant transport to simulate the pathway to exposed point. This study investigated the contaminant migration through in the pollutant exposure pathway of vadoze zone for risk assessment of the contaminated site. For the purpose, generic scenarios as well as contaminant-based scenarios were simulated using the numerical code for transport of the contaminant in the pathway. The finite-difference one-dimensional transport with adsorption and biodegradation were considered, and it also assumed that the initial concentration was also depleted over time. The results of the generic-scenario show that as the groundwater infiltration rate decreases, the longer the path from the source to the groundwater level, the lower the concentration at the point of inflow into the groundwater level. In particular, in the case of high biodegradation rate and rapid depletion of pollutant sources, statistically outliers were found in the simulated results and generic scenarios was good at prediction.

Characterization of Basal Plane Dislocations in PVT-Grown SiC by Transmission Electron Microscopy

  • Jeong, Myoungho;Kim, Dong-Yeob;Hong, Soon-Ku;Lee, Jeong Yong;Yeo, Im Gyu;Eun, Tai-Hee;Chun, Myoung-Chuel
    • Korean Journal of Materials Research
    • /
    • v.26 no.11
    • /
    • pp.656-661
    • /
    • 2016
  • 4H- and 6H-SiC grown by physical vapor transport method were investigated by transmission electron microscopy (TEM). From the TEM diffraction patterns observed along the [11-20] zone axis, 4H- and 6H-SiC were identified due to their additional diffraction spots, indicating atomic stacking sequences. However, identification was not possible in the [10-10] zone axis due to the absence of additional diffraction spots. Basal plane dislocations (BPDs) were investigated in the TEM specimen prepared along the [10-10] zone axis using the two-beam technique. BPDs were two Shockley partial dislocations with a stacking fault (SF) between them. Shockley partial BPDs arrayed along the [0001] growth direction were observed in the investigated 4H-SiC. This arrayed configuration of Shockley partial BPDs cannot be recognized from the plan view TEM with the [0001] zone axis. The evaluated distances between the two Shockley partial dislocations for the investigated samples were similar to the equilibrium distance, with values of several hundreds of nanometers or even values as large as over a few micrometers.

Study on High Speed Routers(II)-Performance Analysis on Various Network Topology of STC104 (고속 라우터에 대한 고찰(II)-STC104의 망 구성에 따른 성능분석)

  • Lee, Hyo-Jong
    • The KIPS Transactions:PartA
    • /
    • v.8A no.2
    • /
    • pp.157-166
    • /
    • 2001
  • A simulation package has been developed as an event-driven system that can handle the hardware configuration of STC104 and algorithm proposed in the sister paper of ‘Study on High Speed Routers(II).’After various STC104 topology of meshes, torus, and hypercubes are constructed using up to 512 switches, the performance of each topology has been analyzed under different message generation rate in terms of throughputs, latency, and packet blocking time. Modified multicast algorithms for STC104 have been proposed for STC104 after U-mesh and U-torus in order to overcome the multicasting difficulty because of the point-to-point communication method found in STC104. The performance of the multicast algorithms have been analyzed over meshes and torus configuration. Throughput gets higher in the order of mesh, torus, and hypercube. Throughput difference among topology were distinctive in the zone of high message generation rate. Latency and blocking time increased in the order of hypercube, torus, and mesh. U-mesh and U-torus of software multicast showed similar throughput, however, U-mesh peformed slightly better result. These algorithms showed eight to ten times better results compared to individual message pass for 90 destination nodes. Multi-link environment also showed better performance than single-link environment because multi-link network used the extra links for communication.

  • PDF