• 제목/요약/키워드: Textile based pressure sensor

검색결과 9건 처리시간 0.02초

Sheath-core 구조 전도사 섬유센서의 Home-Textile 적용을 위한 전기·물리학적 특성연구 (Electrical and Physical Properties of Sheath-core Type Conductive Textile Sensor with Home-Textile)

  • 조광년;정현미
    • 한국의류산업학회지
    • /
    • 제16권1호
    • /
    • pp.145-152
    • /
    • 2014
  • The usage of textile-based sensors has increased due to their many advantages (compared to IT sensors) when applied to body assessment and comfort. Textile-based sensors have different detecting factors such as pressure, voltage, current and capacitance to investigate the characteristics. In this study, textile-based sensor fabrics with sheath-core type conductive yarns were produced and the relationship between capacitance changes and applied load was investigated. The physical and electric properties of textile-based sensor fabrics were also investigated under various laminating conditions. A textile based pressure sensor that uses a sheath-core conductive yarn to ensure the stability of the pressure sensor in the textile-based sensor (the physical structure of the reaction characteristic of the capacitance) is important for the stability of the initial value of the initial capacitance value outside the characteristic of the textile structural environment. In addition, a textile based sensor is displaced relative to the initial value of the capacitance change according to pressure changes in the capacitance value of the sensor due to the fineness of the high risk of noise generation. Changing the physical structure of the fabric through the sensor characteristic of the pressure sensor via the noise generating element of laminating (temperature, humidity, and static electricity) to cut off the voltage output element to improve the data reliability could be secured.

PEDOT 기상중합 원단을 이용한 멀티 레이어 압력 센서 개발 (Development of Multi-layer Pressure Sensor using PEDOT Vapor Phase Polymerization)

  • 임승주;배종혁;장성진;임지영;박근혜;고재훈
    • 센서학회지
    • /
    • 제27권3호
    • /
    • pp.186-191
    • /
    • 2018
  • Smart textile industries have been precipitously developed and extended to electronic textiles and wearable devices in recent years. In particular, owing to an increasingly aging society, the elderly healthcare field has been highlighted in the smart device industries, and pressure sensors can be utilized in various elderly healthcare products such as flooring, mattress, and vital-sign measuring devices. Furthermore, elderly healthcare products need to be more lightweight and flexible. To fulfill those needs, textile-based pressure sensors is considered to be an attractive solution. In this research, to apply a textile to the second layer using a pressure sensing device, a novel type of conductive textile was fabricated using vapor phase polymerization of poly(3,4-ethylenedioxythiophene) (PEDOT). Vapor phase polymerization is suitable for preparing the conductive textile because the reaction can be controlled simply under various conditions and does not need high-temperature processing. The morphology of the obtained PEDOT-conductive textile was observed through the Field Emission Scanning Electron Microscope (FESEM). Moreover, the resistance was measured using an ohmmeter and was confirmed to be adjustable to various resistance ranges depending on the concentration of the oxidant solution and polymerization conditions. A 3-layer 81-point multi-pressure sensor was fabricated using the PEDOT-conductive textile prepared herein. A 3D-viewer program was developed to evaluate the sensitivity and multi-pressure recognition of the textile-based multi-pressure sensor. Finally, we confirmed the possibility that PEDOT-conductive textiles could be utilized by pressure sensors.

운전자의 체압 분포 및 시트변형에 대한 정량화 측정시스템 (Body Pressure Distribution and Textile Surface Deformation Measurement for Quantification of Automotive Seat Design Attributes)

  • 권영은;김윤영;이용구;이동규;권오원;강신원;이강호
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.397-402
    • /
    • 2018
  • Proper seat design is critical to the safety, comfort, and ergonomics of automotive driver's seats. To ensure effective seat design, quantitative methods should be used to evaluate the characteristics of automotive seats. This paper presents a system that is capable of simultaneously monitoring body pressure distribution and surface deformation in a textile material. In this study, a textile-based capacitive sensor was used to detect the body pressure distribution in an automotive seat. In addition, a strain gauge sensor was used to detect the degree of curvature deformation due to high-pressure points. The textile-based capacitive sensor was fabricated from the conductive fabric and a polyurethane insulator with a high signal-to-noise ratio. The strain gauge sensor was attached on the guiding film to maximize the effect of its deformation due to bending. Ten pressure sensors were placed symmetrically in the hip area and six strain gauge sensors were distributed on both sides of the seat cushion. A readout circuit monitored the absolute and relative values from the sensors in realtime, and the results were displayed as a color map. Moreover, we verified the proposed system for quantifying the body pressure and fabric deformation by studying 18 participants who performed three predefined postures. The proposed system showed desirable results and is expected to improve seat safety and comfort when applied to the design of various seat types. Moreover, the proposed system will provide analytical criteria in the design and durability testing of automotive seats.

높은 민감도 및 우수한 피부 통기성을 가진 마이크로 섬유 기반의 직물형 유연 압력 센서 (Microfiber-based Textile Pressure Sensor with High Sensitivity and Skin-breathability)

  • 한강토;최장희;임정우;공혜영;배근열
    • 한국염색가공학회지
    • /
    • 제35권3호
    • /
    • pp.179-187
    • /
    • 2023
  • In this study, we developed a microfiber-based flexible pressure sensor with high sensitivity and excellent skin breathability. A nonwoven fabric composed of microfibers was prepared by electrospinning, which resulted in excellent moisture permeability of the sensor (143 g∙m-2∙h-1). In particular, high-pressure sensitivity (0.36 kPa-1) was achieved by introducing submicron structures on the microfiber surface by controlling the ambient humidity during electrospinning. The fabrication technology of the microfiber-based flexible pressure sensors reported in this study is expected to contribute to the commercialization of flexible pressure sensors applicable to long-term wearable health monitoring as well as virtual/augmented reality and electronic skin applications.

Activity and Safety Recognition using Smart Work Shoes for Construction Worksite

  • Wang, Changwon;Kim, Young;Lee, Seung Hyun;Sung, Nak-Jun;Min, Se Dong;Choi, Min-Hyung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권2호
    • /
    • pp.654-670
    • /
    • 2020
  • Workers at construction sites are easily exposed to many dangers and accidents involving falls, tripping, and missteps on stairs. However, researches on construction site monitoring system to prevent work-related injuries are still insufficient. The purpose of this study was to develop a wearable textile pressure insole sensor and examine its effectiveness in managing the real-time safety of construction workers. The sensor was designed based on the principles of parallel capacitance measurement using conductive textile and the monitoring system was developed by C# language. Three separate experiments were carried out for performance evaluation of the proposed sensor: (1) varying the distance between two capacitance plates to examine changes in capacitance charges, (2) repeatedly applying 1 N of pressure for 5,000 times to evaluate consistency, and (3) gradually increasing force by 1 N (from 1 N to 46 N) to test the linearity of the sensor value. Five subjects participated in our pilot test, which examined whether ascending and descending the stairs can be distinguished by our sensor and by weka assessment tool using k-NN algorithm. The 10-fold cross-validation method was used for analysis and the results of accuracy in identifying stair ascending and descending were 87.2% and 90.9%, respectively. By applying our sensor, the type of activity, weight-shifting patterns for balance control, and plantar pressure distribution for postural changes of the construction workers can be detected. The results of this study can be the basis for future sensor-based monitoring device development studies and fall prediction researches for construction workers.

Implementation of Real-time Sedentary Posture Correction Cushion Using Capacitive Pressure Sensor Based on Conductive Textile

  • Kim, HoonKi;Park, HyungSoo;Oh, JiWon
    • 한국컴퓨터정보학회논문지
    • /
    • 제27권2호
    • /
    • pp.153-161
    • /
    • 2022
  • 일상생활의 전반에 걸쳐 필요한 생활용품들이 자동화, 스마트화, 지능화됨으로 인해 물리적인 활동이 줄고 앉아 있는 시간이 늘어가는 추세이다. 최근 헬스케어 연구에서는 앉아 있는 시간에 비례해서 비만, 당뇨병, 심장혈관질환, 그리고 조기사망의 가능성이 높아진다고 보고되었다. 본 논문에서는 전도성 섬유 기반 전기용량성 압력 센서를 이용한 실시간 앉은 자세 교정 방석을 개발한다. 자세 교정 방석의 핵심 부품인 전도성 섬유를 이용한 압력 센서를 개발하고, 저전력 기반의 압력 측정 회로를 개발한다. 자세 교정 방석에서 BLE(Bluetooth Low Energy) 근거리 무선통신을 이용하여 실시간으로 측정된 센서값을 스마트 폰으로 전송할 수 있는 기능을 제공하고, 이 센서값을 통해 앉은 자세의 상태를 확인할 수 있도록 모바일 앱을 개발한다. 모바일 앱에서는 앉은 자세를 시각화하여 실시간으로 확인할 수 있고 잘못된 자세로 일정시간 유지할 경우 알람으로 알릴 수 있다. 또한, 앉아 있는 시간 및 자세 정확도를 그래프로 시각화할 수 있도록 한다. 본 논문의 교정 방석을 통해 사용자의 앉아 있는 자세 상태를 인지하여 실제적으로 사용자 자세 교정에 얼마나 효과적인지를 실험해 보고 타제품과 비교하여 차별성과 우수성을 제시한다.

호흡 측정 기능의 스마트 의류를 위한 기초 디자인 연구 (A Study of the Basic Design for Smart Clothing based on Measurement of the Respiration)

  • 조하경;민세동
    • 감성과학
    • /
    • 제15권4호
    • /
    • pp.415-424
    • /
    • 2012
  • 1990년대 이후 웰빙 라이프스타일의 도입 및 인구 고령화 사회의 진입으로 인해 언제 어디서나 지속적으로 측정가능한 생체 신호 센싱 모니터링 시스템에 대한 관심이 높아지고 있다. 이에 따라, 최근 지속적으로 호흡 측정이 가능한 시스템에 대한 연구 및 개발이 활발히 이루어지고 있으나 소비자 수요에 기반한 스마트 의류적용을 위한 호흡 측정 시스템의 연구는 미비하다. 따라서, 본 연구에서는 압전의 원리를 이용하여 호흡시 인체의 체표면이 변화하면서 센서에 가해지는 압력을 전기적 신호로 바꾸어 호흡을 측정하는, 전도성 섬유기반의 전기용량성 섬유 압력 센서(Textile Capacitive Pressure Sensor, TCPS)를 개발하였으며, 이를 실증적 연구를 통해 센서의 유용성을 입증하고자 하였다. 그 결과, Nasal로부터 측정된 호흡율과 TCPS를 통해 측정된 호흡율간의 상관계수는 r=0.9553 (p< 0.0001)로 TCPS의 신호 측정 정확성을 확인할 수 있었으며, 또한, 사용성 및 착용성 평가의 결과 인지적 변화, 착용성, 운동성, 관리의 용이성 및 유용성에서 모두 만족한다 정도의 평가 결과를 가져와 본 연구에서 개발된 TCPS의 착용성 및 의류 적합성을 입증하였다. 마지막으로 TCPS의 의류 적합 위치 평가 결과는 복부 부위에서 신호의 안정감을 갖으며, 착용감도 높은 것으로 나타났다. 최종적으로, 위의 결과들을 종합하여 호흡 측정 기능의 스마트 의류 개발을 위한 기초 디자인을 제시하였다.

  • PDF

생체신호 모니터링을 위한 CNT 기반 스페이서 직물 압력센서 구현 및 센싱 능력 평가 (Carbon-nanotube-based Spacer Fabric Pressure Sensors for Biological Signal Monitoring and the Evaluation of Sensing Capabilities)

  • 윤하영;김상운;김주용
    • 감성과학
    • /
    • 제24권2호
    • /
    • pp.65-74
    • /
    • 2021
  • 최근 ICT 산업의 기술혁신이 일어남에 따라 생체신호을 인식하고 이에 대해 대응을 하기 위한 웨어러블 센싱 장치에 대한 수요가 증가하고 있다. 이에 따라 본 연구에서는 단순한 함침과정을 통해 3차원 스페이서(3D spacer)직물을 단일벽 탄소나노튜브(SWCNT)분산용액에 함침공정을 진행해 단일층(monolayer) 압전 저항형 압력 센서(piezoresistive pressure sensor)를 개발하였다. 3D 스페이서 원단에 전기전도성을 부여하기 위해 시료를 SWCNT 분산용액에 함침공정을 진행한 후 건조하는 과정을 거쳤다. 함침된 시료의 전기적 특성을 파악하기 위해 UTM (Universal Testing Machine)과 멀티미터를 이용해서 압력의 변화에 따른 저항의 변화를 측정하였다. 또한 센서의 전기적 특성의 변화를 관찰하기 위해 분산용액의 농도, 함침횟수, 시료의 두께를 다르게 해서 시료의 센서로서의 성능을 평가했다. 그 결과 wt0.1%의 SWCNT 분산용액에 함침공정을 2번 진행한 시료가 센서로서 가장 뛰어난 성능을 나타냄을 알 수 있었다. 두께별로는 7mm 두께의 센서가 가장 높은 GF를 보이고 13mm 두께의 센서가 작동범위가 가장 넓음을 확인했다. 본 연구를 통해 3D spacer 원단으로 제작한 스마트 텍스타일 센서는 공정과정이 단순하면서도 센서로서 성능이 뛰어나다는 장점을 확인할 수 있었다.

Ti3Ci2Tix MXene 기반 전극 소재의 자가 치유 적용 기술 개발 동향 (Recent Progress of Ti3Ci2Tix MXene Electrode Based Self-Healing Application)

  • 최준상;정승부;김종웅
    • 마이크로전자및패키징학회지
    • /
    • 제30권3호
    • /
    • pp.20-34
    • /
    • 2023
  • 수 나노미터의 두께의 단일 또는 여러 층으로 구성된 2차원 소재는 전기전도성, 유연성, 광학적 투명성 등의 고유한 특성으로 많은 연구 분야에서 활용되고 있다. 이 중 Electronic skin (E-Skin)이나 Smart Textile 과 같은 반복적인 기계적 동작이 수반될 수 있다. 또한, 온도, 습도, 압력과 같은 외부적 요인에 노출이 되는 경우가 빈번하다. 이 때, 소자의 내구성과 수명 저하를 유발하기 때문에 자가 치유 특성이 내포된 소자를 제작하기 위한 연구가 많이 이루어지고 있다. 최근 다양한 2차원 소재 중 자가 치유 기능을 구현할 수 있는 Ti3Ci2Tix MXene 기반 전극의 복합 소재의 연구 결과가 학계의 주목을 받고 있다. 본 논문에서는 Ti3Ci2Tix MXene의 다양한 합성 방법 및 특성에 대해 소개한 후, Ti3Ci2Tix MXene 전극 기반의 자가 치유 적용 기술 사례에 대해 알아보고자 한다.