• Title/Summary/Keyword: Testing procedure

Search Result 873, Processing Time 0.031 seconds

Estimation of Groundwater Recharge by Considering Runoff Process and Groundwater Level Variation in Watershed (유역 유출과정과 지하수위 변동을 고려한 분포형 지하수 함양량 산정방안)

  • Chung, Il-Moon;Kim, Nam-Won;Lee, Jeong-Woo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.5
    • /
    • pp.19-32
    • /
    • 2007
  • In Korea, there have been various methods of estimating groundwater recharge which generally can be subdivided into three types: baseflow separation method by means of groundwater recession curve, water budget analysis based on lumped conceptual model in watershed, and water table fluctuation method (WTF) by using the data from groundwater monitoring wells. However, groundwater recharge rate shows the spatial-temporal variability due to climatic condition, land use and hydrogeological heterogeneity, so these methods have various limits to deal with these characteristics. To overcome these limitations, we present a new method of estimating recharge based on water balance components from the SWAT-MODFLOW which is an integrated surface-ground water model. Groundwater levels in the interest area close to the stream have dynamics similar to stream flow, whereas levels further upslope respond to precipitation with a delay. As these behaviours are related to the physical process of recharge, it is needed to account for the time delay in aquifer recharge once the water exits the soil profile to represent these features. In SWAT, a single linear reservoir storage module with an exponential decay weighting function is used to compute the recharge from soil to aquifer on a given day. However, this module has some limitations expressing recharge variation when the delay time is too long and transient recharge trend does not match to the groundwater table time series, the multi-reservoir storage routing module which represents more realistic time delay through vadose zone is newly suggested in this study. In this module, the parameter related to the delay time should be optimized by checking the correlation between simulated recharge and observed groundwater levels. The final step of this procedure is to compare simulated groundwater table with observed one as well as to compare simulated watershed runoff with observed one. This method is applied to Mihocheon watershed in Korea for the purpose of testing the procedure of proper estimation of spatio-temporal groundwater recharge distribution. As the newly suggested method of estimating recharge has the advantages of effectiveness of watershed model as well as the accuracy of WTF method, the estimated daily recharge rate would be an advanced quantity reflecting the heterogeneity of hydrogeology, climatic condition, land use as well as physical behaviour of water in soil layers and aquifers.

TENSILE STRENGTHS OF PRE-LIGATURED BUTTON WITH SEVERAL TYPES OF CONTAMINATION IN DIRECT BONDING PROCEDURE WHICH CAN HAPPEN DURING THE SURGICAL EXPOSURE OF UNERUPTED TEETH (치아의 견인을 위한 버튼 접착시 오염이 인장강동에 미치는 영향)

  • Kim, Seong-Oh;Choi, Byung-Jai;Lee, Jae-Ho;Sohn, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.400-420
    • /
    • 1998
  • We already know that it is very difficult to obtain an "isolated field" for direct bonding during the surgical exposure of unerupted teeth. The aim of this in-vitro study is to simulate the clinical situation of forced eruption and to evaluate the tensile strengths of preligatured button with several types of contamination which can happen during the surgical exposure of unerupted teeth. Four orthodontic direct bonding systems were used. ($Ortho-One^{TM}$, $Rely-a-Bond^{(R)}$, $Ortho-Two^{TM}$, Phase $II^{(R)}$) Each material was divided into four groups(n=20) : Group 1. (Control, no contamination), Group 2. (Rinse etching agent with saline instead of water), Group 3. (Blood contamination of etched surface for 30 seconds), Group 4. (Blood contamination of primed surface for 30 seconds) 320 bovine anterior permanent teeth were divided into the above mentioned 16 groups. Enamel surface was flattened and ground under water coolant. Pre-ligatured buttons were prepared to the same form. (Cut 0.25 ligature wire 10 cm in length. Twist the ligature wire 30 times clockwise. Mark the wire 15mm and 35mm points from button. Make a loop sticking two points together and twist the loop 6 times counterclockwise.) The bonded specimens were stored at $37^{\circ}C$ saline solution for 3 days. Then the tensile strength of each sample was measured with Instron universal testing machine, crosshead speed of 0.5mm/min. The following results were obtained: 1. As compared to control groups (Group 1) of each material, Rely-a-Bond had a significantly lower mean tensile strengths than other material. (p<0.01) 2. In Group 2. of Ortho-One and Rely-a-Bond, the mean tensile strengths decreased about 7.7% and 11.1%, respectively with statistical significances. (p<0.05) 3. In Group 2. of Ortho-Two and Phase II, the mean tensile strengths did not decrease. 4. In Group 3. of Ortho-One, Rely-a-Bond, Ortho-Two, and Phase II, the mean tensile strengths decreased about 60.8%, 56.1%, 60.2%, and 46.0%, respectively with statistical significances. (p<0.01) 5. In Group 4. of Ortho-One and Rely-a-Bond, the mean tensile strengths did not decrease. 6. In Group 4. of Ortho-Two and Phase II, the mean tensile strengths were decreased about 20.95% and 22.28%, respectively with statistical significances. (p<0.01) There were formations of a hump shaped mass from bonding resin under blood contamination which disturbed direct bonding procedure. According to Reynolds, the proper bond strength for clinical manipulation should be at least 45N or about 4.5Kg.F. According to these results, it can be concluded that Ortho-One could be used during surgical exposure of unerupted teeth. In any case, blood contamination of the etched surface should be avoided, but the blood contamination of primed surface of Ortho-One may not decrease bond strength. Just 'blowing-out' is enough to remove blood from primed surface of Ortho-One. You can verify the clean surface of the primer of Ortho-One after blowing out the blood contamination.

  • PDF

APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM (Acidic primer를 이용한 교정용 브라켓 접착의 전단결합강도)

  • Kim, Jin-Hee;Jin, Hun-Hee;Oh, Jang-Kyun
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.137-147
    • /
    • 2001
  • Acidic primer is the bonding agent which combines the conditioning and priming agent into the single solution and was originally developed for the dentin bonding system. It is less harmful to the tooth structure and more convenient to manipulate than the traditional etching procedure. The Purpose of this study is to evaluate the shear bond strength of various bonding materials when the enamel is treated with acidic primer for the bracket bonding procedure. Fifty recently extracted human premolars were randomly separated into five groups -Group I using Clearfil Liner Bond 2 adhesive system to the enamel treated with acidic primer, Group II using Transbond XT adhesive system to the enamel treated with acidic primer, Group III using panavia 21 adhesive system to the enamel treated with acidic primer, Group IV using Fuji-Ortho LC adhesive system to the enamel treated with acidic primer, Group V using Transbond XT adhesive system to the enamel treated with 37$\%$ phosphoric acid. The shear bond strength was measured with Instron universal testing machine after storing in $37^{\circ}C$ water bath for 48 hours. After debonding, the teeth and brackets were examined under scanning electron microscope (SEM) and assessed with the adhesive remnant index (ARI). The results were as follows : 1. There were no significant differences in shear bond strength between group III ($8.69{\pm}2.72MPa$), group IV (9.7 ± 3.16 MPa), and group V ($10.48{\pm}2.60MPa$) (p>0.05). 2. The shear bond strength of group III and group IV was significantly higher than that of group I ($1.09{\pm}0.53MPa$), and Group II ($2.70{\pm}1.46MPa$) (p<0.05). 3. The ARI of group IV ($2.1{\pm}1.1$) and group V ($2.9{\pm}0.3$) was significantly higher than that of group I ($0.2{\pm}0.4$), group II ($0.3{\pm}0.9$) and group III ($0.2{\pm}0.4$) (p<0.05). 4. There were no significant difference between the ARI of group IV and group V (p>0.05). This result suggests that the combination of acidic primer and some bonding adhesive can provide sufficient shear bond strength for clinical orthodontics.

  • PDF

Assembly and Testing of a Visible and Near-infrared Spectrometer with a Shack-Hartmann Wavefront Sensor (샤크-하트만 센서를 이용한 가시광 및 근적외선 분광기 조립 및 평가)

  • Hwang, Sung Lyoung;Lee, Jun Ho;Jeong, Do Hwan;Hong, Jin Suk;Kim, Young Soo;Kim, Yeon Soo;Kim, Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.3
    • /
    • pp.108-115
    • /
    • 2017
  • We report the assembly procedure and performance evaluation of a visible and near-infrared spectrometer in the wavelength region of 400-900 nm, which is later to be combined with fore-optics (a telescope) to form a f/2.5 imaging spectrometer with a field of view of ${\pm}7.68^{\circ}$. The detector at the final image plane is a $640{\times}480$ charge-coupled device with a $24{\mu}m$ pixel size. The spectrometer is in an Offner relay configuration consisting of two concentric, spherical mirrors, the secondary of which is replaced by a convex grating mirror. A double-pass test method with an interferometer is often applied in the assembly process of precision optics, but was excluded from our study due to a large residual wavefront error (WFE) in optical design of 210 nm ($0.35{\lambda}$ at 600 nm) root-mean-square (RMS). This results in a single-path test method with a Shack-Hartmann sensor. The final assembly was tested to have a RMS WFE increase of less than 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm. During the procedure, we confirmed the validity of using a Shack-Hartmann wavefront sensor to monitor alignment in the assembly of an Offner-like spectrometer.

A Validating Academic Engagement as a Multidimensional Construct for Korean College Students: Academic Motivation, Engagement, and Satisfaction (대학생용 학업참여 척도(UWES-S)의 타당화: 학업동기, 참여 및 만족도의 구조적 관계)

  • Choo, Huntaek;Sohn, Wonsook
    • Korean Journal of School Psychology
    • /
    • v.9 no.3
    • /
    • pp.485-503
    • /
    • 2012
  • Academic engagement has been known as a strong predictor of students' cognitive and affective outcomes in an educational context. Despite increasing interest and theoretical usefulness of this construct, a few researchers seem to be interested in the validation of instruments to measure academic engagement for Korean students. Thus, this study would like to introduce one of academic scales widely used, UWES-S(Utrecht Work Engagement Scale-Student) (Schaufeli et al., 2002a: 2002b) and to validate the UWES-S for Korean college students. To validate the Korean version of the UWES-S, 651 college students (285 for Field Trial, 366 for Main Study) were used. The procedure is as follows. First, we used an integrated adaptation procedure to produce a Korean version of the UWES-S. Second, EFA(exploratory factor analyses) was applied to explore the factor structure of the UWES-S on the field trial data. Third, the psychometric properties of the UWES-S items were examined by graded response model(GRM). Also CFA(confirmatory factor analysis) was used to examine its internal construct validity for the data from the main study. Finally, the external validity of the UWES-S was scrutinized with the related variables such as academic motivation and satisfaction. As a result, the Korean version of the UWES-S with 13 items was accepted that the four items were excluded from its original version. Second, the internal validity was supported that the 3 factor CFA model(vigor, dedication, absorption) fit the data well. Third, we supported the partial mediation model that academic engagement played as a mediating variable between academic motivation(internal/external) and academic satisfaction. Finally, the differences between a validation of UWES-S for Korean college and high school students, the necessity of construct equivalence testing, and direction for future research of scale validating were discussed.

Effects of firm strategies on customer acquisition of Software as a Service (SaaS) providers: A mediating and moderating role of SaaS technology maturity (SaaS 기업의 차별화 및 가격전략이 고객획득성과에 미치는 영향: SaaS 기술성숙도 수준의 매개효과 및 조절효과를 중심으로)

  • Chae, SeongWook;Park, Sungbum
    • Journal of Intelligence and Information Systems
    • /
    • v.20 no.3
    • /
    • pp.151-171
    • /
    • 2014
  • Firms today have sought management effectiveness and efficiency utilizing information technologies (IT). Numerous firms are outsourcing specific information systems functions to cope with their short of information resources or IT experts, or to reduce their capital cost. Recently, Software-as-a-Service (SaaS) as a new type of information system has become one of the powerful outsourcing alternatives. SaaS is software deployed as a hosted and accessed over the internet. It is regarded as the idea of on-demand, pay-per-use, and utility computing and is now being applied to support the core competencies of clients in areas ranging from the individual productivity area to the vertical industry and e-commerce area. In this study, therefore, we seek to quantify the value that SaaS has on business performance by examining the relationships among firm strategies, SaaS technology maturity, and business performance of SaaS providers. We begin by drawing from prior literature on SaaS, technology maturity and firm strategy. SaaS technology maturity is classified into three different phases such as application service providing (ASP), Web-native application, and Web-service application. Firm strategies are manipulated by the low-cost strategy and differentiation strategy. Finally, we considered customer acquisition as a business performance. In this sense, specific objectives of this study are as follows. First, we examine the relationships between customer acquisition performance and both low-cost strategy and differentiation strategy of SaaS providers. Secondly, we investigate the mediating and moderating effects of SaaS technology maturity on those relationships. For this purpose, study collects data from the SaaS providers, and their line of applications registered in the database in CNK (Commerce net Korea) in Korea using a questionnaire method by the professional research institution. The unit of analysis in this study is the SBUs (strategic business unit) in the software provider. A total of 199 SBUs is used for analyzing and testing our hypotheses. With regards to the measurement of firm strategy, we take three measurement items for differentiation strategy such as the application uniqueness (referring an application aims to differentiate within just one or a small number of target industry), supply channel diversification (regarding whether SaaS vendor had diversified supply chain) as well as the number of specialized expertise and take two items for low cost strategy like subscription fee and initial set-up fee. We employ a hierarchical regression analysis technique for testing moderation effects of SaaS technology maturity and follow the Baron and Kenny's procedure for determining if firm strategies affect customer acquisition through technology maturity. Empirical results revealed that, firstly, when differentiation strategy is applied to attain business performance like customer acquisition, the effects of the strategy is moderated by the technology maturity level of SaaS providers. In other words, securing higher level of SaaS technology maturity is essential for higher business performance. For instance, given that firms implement application uniqueness or a distribution channel diversification as a differentiation strategy, they can acquire more customers when their level of SaaS technology maturity is higher rather than lower. Secondly, results indicate that pursuing differentiation strategy or low cost strategy effectively works for SaaS providers' obtaining customer, which means that continuously differentiating their service from others or making their service fee (subscription fee or initial set-up fee) lower are helpful for their business success in terms of acquiring their customers. Lastly, results show that the level of SaaS technology maturity mediates the relationships between low cost strategy and customer acquisition. That is, based on our research design, customers usually perceive the real value of the low subscription fee or initial set-up fee only through the SaaS service provide by vender and, in turn, this will affect their decision making whether subscribe or not.

The nanoleakage patterns of experimental hydrophobic adhesives after load cycling (Load cycling에 따른 소수성 실험용 상아질 접착제의 nanoleakage 양상)

  • Sohn, Suh-Jin;Chang, Ju-Hae;Kang, Suk-Ho;Yoo, Hyun-Mi;Cho, Byeong-Hoon;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.1
    • /
    • pp.9-19
    • /
    • 2008
  • The purpose of this study was: (1) to compare nanoleakage patterns of a conventional 3-step etch and rinse adhesive system and two experimental hydrophobic adhesive systems and (2) to investigate the change of the nanoleakage patterns after load cycling. Two kinds of hydrophobic experimental adhesives, ethanol containing adhesive (EA) and methanol containing adhesive (MA), were prepared. Thirty extracted human molars were embedded in resin blocks and occlusal thirds of the crowns were removed. The polished dentin surfaces were etched with a 35 % phosphoric acid etching gel and rinsed with water. Scotchbond Multi-Purpose (MP), EA and MA were used for bonding procedure. Z-250 composite resin was built-up on the adhesive-treated surfaces. Five teeth of each dentin adhesive group were subjected to mechanical load cycling. The teeth were sectioned into 2 mm thick slabs and then stained with 50 % ammoniacal silver nitrate. Ten specimens for each group were examined under scanning electron microscope in backscattering electron mode. All photographs were analyzed using image analysis software. Three regions of each specimen were used for evaluation of the silver uptake within the hybrid layer. The area of silver deposition was calculated and expressed in gray value. Data were statistically analyzed by two-way ANOVA and post-hoc testing of multiple comparisons was done with the Scheffe's test. Silver particles were observed in all the groups. However, silver particles were more sparsely distributed in the EA group and the MA group than in the MP group (p < .0001). There were no changes in nanoleakage patterns after load cycling.

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Development of BIM-based 3D Modeling Instruction Materials and its Application Analysis for Professional Drafting Subject of Specialized Vocational High School (특성화고 전문제도 과목을 위한 BIM 기반 3D 주택설계 수업자료 개발 및 적용)

  • Kwon, Se-Jeong;Yoo, Hyun-Seok
    • 대한공업교육학회지
    • /
    • v.43 no.1
    • /
    • pp.1-19
    • /
    • 2018
  • As the BIM designing technology has been applied recently in the construction field, architectural design education in the field of work and university has been changing to 3D modeling. Nevertheless, architectural design & drafting education in the construction specialized vocational high school is not responding appropriately to change. Despite the fact that students need to have 3D modeling design ability, there is a very lack of 3D housing design instructional material that can satisfy the change. The purpose of this study is to develop BIM-based 3D modeling instruction material and apply to analyze effect on interest and task performance ability on Housing Design. The 3D modeling instruction material used in this study was developed through four stages of preparation, development, implementation and evaluation according to the PDIE model procedure. Also, the experimental design model for hypothesis testing was used nonequivalent control group pretest-posttest design. Based on the experimental design model, BIM-based 3D modeling instruction material was performed in the experimental group and 2D CAD-based standard instruction material was taught in the control group. Experimental treatment was conducted on the students of construction specialized vocatinonal high school, and applied to the subject of Professional Drafting in the 12 hours. Before and after the experimental treatment, the interest and task performance ability on Housing Design were tested. Based on the test results, we analyzed the effects of the 3D modeling instruction material through the independent samples t-test. The results of the study are as follows. First, BIM-based 3D modeling instruction material was developed of 'Housing Design & Drafting' unit on the subject of Professional Drafting in construction specialized vocational high school. Second, the application of 3D modeling instruction material has shown to be effective in improving students' interest. Third, the application of 3D modeling instruction material has shown to be effective in improving students' task performance ability on Housing Design.

The Effect of Au Addition on the Hardening Mechanism in Ag-25wt% Pd-15wt% Cu (Ag-25wt% Pd-15wt% Cu 3원합금(元合金) 및 Au 첨가합금(添加合金)의 시효경화특성(時效京華特性))

  • Bea, B.J.;Lee, H.S.;Lee, K.D.
    • Journal of Technologic Dentistry
    • /
    • v.20 no.1
    • /
    • pp.37-49
    • /
    • 1998
  • The specimens used were Ag-25 Pd-15 Cu ternary alloy and Au addition alloy. These alloys were melted and casted by induction electric furnace and centrifugal casting machine in Ar atmosphere. These specimens were solution treated for 2hr at $800^{\circ}C$ and were then quenched into iced water, and aged at $350{\sim}550^{\circ}C$ Age- hardening characteristics of the small Au-containing Ag-Pd-Cu dental alloys were investigated by means of hardness testing. X-ray diffraction and electron microscope observations, electrical resistance, ergy dispersed spectra and electron probe microanalysis. Principal results are as follows : Hardening occured in two stages, i.e., stage I in low temperature and stage II in high temperature regions, during continuous aging. The case of hardening in stage I was due to the formation of the $L1_0$ type face-centered tetragonal PdCu-ordered phase in the grain interior and hardening in stage I was affected by the Cu concentration. In stage II, decomposition of the ${\alpha}$ solid solution to a PdCu ordered phase($L1_0$ type) and an Ag-rich ${\alpha}2$ phase occurred and a discontinuous precipitation occurred at the grain boundary. From the electron microscope study, it was conclued that the cause of age-hardening in this alloy is the precipitation of the PdCu ordered phase, which has AuCu I type face-centered tetragonal structure. Precipetation procedure was ${\alpha}{\to}{\alpha}+{\alpha}_2+PdCu {\to}{\alpha}_1+{\alpha}_2+PdCu$ at Pd/Cu = 1.7 Ag-Pd-Cu alloy is more effective dental alloy as ageing treatment and is suitable to isothermal ageing at $450^{\circ}C$.

  • PDF