• Title/Summary/Keyword: Testing Temperature

Search Result 1,540, Processing Time 0.029 seconds

Defect Measurement of Graphites for High Temperature Application by AE Technique (AE 계측에 의한 고온용 흑연재료의 경함측정에 관한 연구)

  • Choe, Man-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.2
    • /
    • pp.122-127
    • /
    • 1992
  • In this study, we investigated defects of graphite by three NDT methods which are ultrasonic testing at 5 MHz, micro-forused X-ray testing and AE testing. As the detection of AE signals generated from graphite tensile specimens, we calculated location of AE sources and compared them with UT and X-ray test results in detecting defects of several specimens, Acoustic emission testing could be applied to some graphites which have fine grains of a few tens of micrometer, but it was difficult to those in lager grain of few fo milimeter. Also, we could understand what kind of defects has affected on tensile fracture of graphite.

  • PDF

Tension Behavior of Nicalon/CAS Ceramic Composites (Nicalon/CAS 세라믹 복합재료의 인장특성)

  • Kim, Jeong-Guk;Kim, Weon-Kyong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.232-237
    • /
    • 2004
  • The tension behavior of Nicalon/CAS glass-ceramic matrix composites was investigated. Infrared (IR) thermography was employed for two different types of $Nicalon^{TM}/CAS$ composites, i.e., cross-ply and unidirectional specimens. During tensile testing, an IR camera was used for in-situ monitoring of progressive damages of $Nicalon^{TM}/CAS$ samples. The IR camera provided the temperature changes during tensile testing. Microstructural characterization using scanning electron microscopy (SEM) was performed to investigate the fracture mechanisms of $Nicalon^{TM}/CAS$ composites. In this investigation, the thermographic NDE technique was used to facilitate a better understanding of the fracture mechanisms of the $Nicalon^{TM}/CAS$ composites during tensile testing.

  • PDF

Estimation of Activation Energy of Electroluminescent film by Accelerated Life Test (가속시험을 통한 Electroluminescent film의 활성화 에너지 추정)

  • Kim, Su-Kyoung;Hyung, Jae-Phil;Oh, Gil-Gu;Lim, Hong-Woo;Kim, Myung-Soo;Oh, Geun-Tae
    • Journal of Applied Reliability
    • /
    • v.15 no.1
    • /
    • pp.52-59
    • /
    • 2015
  • In this Study, we tested electroluminescent film to accelerate life by temperature, humidity, voltage, and frequency. We analyzed brightness data to estimate activation energy and verify it's suitability. All of the tests performed in operating condition. Because electroluminescent film is mostly degraded by fluorescent in operating condition. Two different sample groups were tested and compared to find common parameter.

Nondestructive Testing Technique using Infrared Thermography (적외선을 이용한 비파괴검사 기술)

  • Park, Moon-Ho;Lee, Ik-Hwan
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 1995
  • Infrared(IR) thermography method was developed as a result of an investigation into a means of deriving a more visual method of temperature analysis. It recently provides an excellant nondestructive testing(NDT) technique in a variety of industries such as nuclear power plant, fossil plants, etc.. This paper offers a basic principles of infrared radiation, the nature of instruments used for measurement and the applications.

  • PDF

Electrode Performance by Accelation Testing in Phosphoric Acid Fuel Cell (가속 시험법에 의한 연료전지 전극 특성)

  • Kim, C.S.;Song, R.H.;Shin, D.R.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1409-1412
    • /
    • 1994
  • The electrodes for Phosphoric Acid Fuel Ceil were fabricated as a condition of PTFE contents in electrocatalyst layer and sintering temperature in the range of 25 -- 65 wt% and 310 -- $390^{\circ}C$, respectively. For the fabricated electrode, the accelation testing of cathode half cell at open circuit potential was investigated. While the performance of electrode showed maximum at the low level of PTFE contents in the initial stage of accelation testing, the maximum performance was shifted to higher PTFE contents of 45wt% after 24hrs accelation testing.

  • PDF

Design and Characteristics Analysis of the 78 kWe Grade Synchronous Generator for Disused Diesel Engines

  • Youn, Jun-Seop;Kim, Hae-Joong;Kim, Youn-Hwan;Moon, Jae-Won
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.122-132
    • /
    • 2017
  • This study dealt with the design process of the 78 kW permanent magnet synchronous generator for engines. After the calculation of the basic dimensions through a theoretical method in the process of initial model design, FEA (finite-element analysis) and a d,q-axis equivalent circuit were used to identify the generator characteristics depending on the number of poles. With the use of the space harmonic analysis method, the back-EMF (electromotive force) and THD were checked, and then the number of slots was determined. In addition, the most optimized generator dimensions were determined through a sizing optimization technique. Based on this, the optimum model with enhanced efficiency, material costs, and temperature characteristics was derived, and the availability of the design method was confirmed through a comparative analysis of the initial and optimum models.

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • Oh, Kyu-Hwan;Jiang, Bo;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF

Wide-Width Tensile Strength Properties of Geogrids according to Specimen Length and Testing Speed (시료크기 및 인장속도에 따른 지오그리드의 광폭인장강도 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Oh, Se-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.2
    • /
    • pp.21-26
    • /
    • 2007
  • The tensile properties of geogrid are affected by such factors as temperature, specimen length, gauge length, testing speed and measuring equipment. The tensile strength of geogrids can be determined by ASTM 06637 and ISO 10319. The main differences between two testing methods are testing speed and specimen length. This paper presents the results of the wide-width tensile tests for three geogrids according to different specimen length and tension speed.

  • PDF

A Study on the Observation of IRR Camera in Surface Discharge Image (표면방전 현상의 적외선 카메라 관측에 관한 연구)

  • Lim, Jang-Seob;Kim, Jin-Gook;Kim, Hyun-Jong;Lee, Woo-Sun;Lee, Jin;Kim, Duck-Keun;Lee, Hack-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.563-566
    • /
    • 2003
  • The conventional testing as IEC-60587 is widely used in suface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF