• Title/Summary/Keyword: Testing & Evaluation Method

Search Result 1,056, Processing Time 0.034 seconds

Development of WebCAT System for ICT Knowledge Ability Evaluation (ICT 소양능력 평가를 위한 WebCAT 시스템의 개발)

  • Lee, Young-Hyoun;Jung, Young-Sik;Kim, Myeong-Ryeol
    • Journal of The Korean Association of Information Education
    • /
    • v.8 no.2
    • /
    • pp.261-268
    • /
    • 2004
  • The Government has established the infrastructure for knowledge and information-oriented society, strengthening the ICT technology education. Although information knowledge ability of learners is prerequisite to educate ICT, but systematic educating courses and time for that are insufficient, and many difficulties have been pointed out. In order to solve such problems, this study developed Web-based computerized adaptive testing system using the item response theory. This system enables the learners to evaluate their own ICT knowledge abilities in their school or home by using familiar web interface and to perform supplementary or deepening study according to the results, and consequently, smooth education of ICT application will be achieved. In addition, this system will be a very effective method for the elementary/middle/high-school ICT knowledge ability certification system.

  • PDF

Effective Test Case Generation for Various Types of Web-based Software (다양한 웹 기반 소프트웨어의 테스트를 위한 효율적인 테스트 케이스의 생성)

  • Kim, Hyun-Soo;Choi, Eun-Man
    • The KIPS Transactions:PartD
    • /
    • v.12D no.4 s.100
    • /
    • pp.569-582
    • /
    • 2005
  • As information and business communication via Internet are growing up, web-based software is wide spread and more important on the viewpoint of software qualify than stand-alone. Research on verification of web content links and web-based Program was tried, but has short on covering various types of web based software and making experiments to be applied in real testing practice. This paper suggests a modeling technique to be applied to dynamic and various types of web-based software. First, it identifies each elements consisting of web-based software and then construct a model of Object Control Flow Graph and Object Relationship Diagram. We can generate test cases covering all test paths of ORD or invoking key points test route. Suggested modeling method and test case selection technique are verified by applying five types of web-based software and compared with other web-based test techniques.

Performance Evaluation of Motorcycle's Anti-theft Device using NFC Authentication and Solenoid Valve (NFC 보안인증과 솔레노이드 밸브를 이용한 이륜차 이동제한장치 성능평가)

  • Moon, Boram;Jin, Taeseok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.1
    • /
    • pp.82-86
    • /
    • 2016
  • This paper proposes a method for the immobilization of motorbike brakes in conjunction with near-field communication (NFC) technology in order to meet the increasing demand for security and convenience of motorbike drivers. We thought about the concept of wireless key, NFC security devices and automatic solenoid valve for setting the lock and unlock module. This paper propose the design and development of an innovative anti-theft alarm system for motorcycles using NFC smart devices based on RFID system, the basis of IoT and AES(advanced encryption standard) encryption Algorithm. The design concept is based on NFC communication strategy between the vehicle and owner. To do this concept, we designed motorcycle smart key system with general-purpose NFC system and the automatic solenoid valve for setting the lock and unlock module. First, we designed control unit and NFC card reader for motorcycle smart key system. Then we propose an AES encryption algorithm and prove that the motorcycle key system is controllable by showing the result of implementing and testing, after installing.

Development and Evaluation of D-Attention Unet Model Using 3D and Continuous Visual Context for Needle Detection in Continuous Ultrasound Images (연속 초음파영상에서의 바늘 검출을 위한 3D와 연속 영상문맥을 활용한 D-Attention Unet 모델 개발 및 평가)

  • Lee, So Hee;Kim, Jong Un;Lee, Su Yeol;Ryu, Jeong Won;Choi, Dong Hyuk;Tae, Ki Sik
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.195-202
    • /
    • 2020
  • Needle detection in ultrasound images is sometimes difficult due to obstruction of fat tissues. Accurate needle detection using continuous ultrasound (CUS) images is a vital stage of treatment planning for tissue biopsy and brachytherapy. The main goal of the study is classified into two categories. First, new detection model, i.e. D-Attention Unet, is developed by combining the context information of 3D medical data and CUS images. Second, the D-Attention Unet model was compared with other models to verify its usefulness for needle detection in continuous ultrasound images. The continuous needle images taken with ultrasonic waves were converted into still images for dataset to evaluate the performance of the D-Attention Unet. The dataset was used for training and testing. Based on the results, the proposed D-Attention Unet model showed the better performance than other 3 models (Unet, D-Unet and Attention Unet), with Dice Similarity Coefficient (DSC), Recall and Precision at 71.9%, 70.6% and 73.7%, respectively. In conclusion, the D-Attention Unet model provides accurate needle detection for US-guided biopsy or brachytherapy, facilitating the clinical workflow. Especially, this kind of research is enthusiastically being performed on how to add image processing techniques to learning techniques. Thus, the proposed method is applied in this manner, it will be more effective technique than before.

Corrosion Durability Evaluation of Uncoated Structural Steel Using Accelerated Exposure Tests (부식촉진실험을 이용한 강교용 무도장 강재의 부식내구성 평가)

  • Kim, In Tae;Itoh, Yoshito
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.79-86
    • /
    • 2007
  • The corrosion durability of steel bridge coatings, such as organic and metallic coatings, is often evaluated by field exposure tests, but such tests take from several years to decades to complete. As a potential method for fast corrosion testing, accelerated exposure tests were considered in this study. The S6-cycle accelerated exposure test, specified in the Japanese Industrial Standards (JIS K5621), was carried out on uncoated structural steels for 30, 60, 90, 120 and 150 days, and the resultant weight loss was determined. The weight loss was compared with that obtained from previous field exposure tests, and acceleration factors of the S6-cycle test to field exposure test sites were determined. The application of the S6-cycle accelerated exposure tests to field environments was presented based on the acceleration factor and the amount of flying salt.

Evaluation for Efficacies of Commercial Sanitizers and Disinfectants against Bacillus cereus Strains

  • Kim, Il-Jin;Ha, Ji-Hyoung;Kim, Yong-Su;Kim, Hyung-Il;Choi, Hyun-Chul;Jeon, Dea-Hoon;Lee, Young-Ja;Kim, Ae-Jung;Bae, Dong-Ho;Kim, Keun-Sung;Lee, Chan;Ha, Sang-Do
    • Food Science and Biotechnology
    • /
    • v.18 no.2
    • /
    • pp.537-540
    • /
    • 2009
  • Bactericidal efficacies of various sanitizers and disinfectants against 10 Bacillus cereus strains isolated from Korean foods and 8 standard B. cereus strains were investigated. The sanitizing capabilities of ethanol, iodine, chloride, quaternary ammonium, hydrogen peroxide, and peroxide acetic acid were investigated using the EN 1276 method based on quantitative suspension testing. The resistance against sanitizers and disinfectants was higher for wild-type than standard strains, and the bactericidal activities decreased in dirty conditions. Ethanol, chlorine, and iodine at the maximum level allowed under Korean food sanitation laws showed a great effectiveness against B. cereus. Hydrogen peroxide at 1,100 ppm showed the lowest bactericidal activity against B. cereus. These results indicate that the legally allowed maximum concentrations of sanitizers and disinfectants in Korea do not reduce all B. cereus strains by at least $5\;{\log}_{10}\;CFU/mL$.

Evaluation of a New Workplace Protection Factor―Measuring Method for Filtering Facepiece Respirator

  • Sun, Chenchen;Thelen, Christoph;Sanz, Iris Sancho;Wittmann, Andreas
    • Safety and Health at Work
    • /
    • v.11 no.1
    • /
    • pp.61-70
    • /
    • 2020
  • Background: This study aims to assess whether the TSI PortaCount (Model 8020) is a measuring instrument comparable with the flame photometer. This would provide an indication for the suitability of the PortaCount for determining the workplace protection factor for particulate filtering facepiece respirators. Methods: The PortaCount (with and without the N95-CompanionTM) was compared with a stationary flame photometer from Moores (Wallisdown) Ltd (Type 1100), which is a measuring instrument used in the procedure for determining the total inward leakage of the particulate filtering facepiece respirator in the European Standard. Penetration levels of sodium chloride aerosol through sample respirators of two brands (A and B) were determined by the two measuring systems under laboratory conditions. For each brand, thirty-six measurements were conducted. The samples were split into groups according to their protection level, conditioning before testing, and aerosol concentration. The relationship between the gauged data from two measuring systems was determined. In addition, the particle size distribution inside the respirator and outside the respirator was documented. Linear regression analysis was used to calculate the association between the PortaCount (with and without the N95-CompanionTM) and the flame photometer. Results: A linear relationship was found between the raw data scaled with the PortaCount (without N95-CompanionTM) and the data detected by the flame photometer (R2 = 0.9704) under all test conditions. The distribution of particle size was found to be the same inside and outside the respirator in almost all cases. Conclusion: Based on the obtained data, the PortaCount may be applicable for the determination of workplace protection factor.

FAULT DETECTION COVERAGE QUANTIFICATION OF AUTOMATIC TEST FUNCTIONS OF DIGITAL I&C SYSTEM IN NPPS

  • Choi, Jong-Gyun;Lee, Seung-Jun;Kang, Hyun-Gook;Hur, Seop;Lee, Young-Jun;Jang, Seung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.421-428
    • /
    • 2012
  • Analog instrument and control systems in nuclear power plants have recently been replaced with digital systems for safer and more efficient operation. Digital instrument and control systems have adopted various fault-tolerant techniques that help the system correctly and safely perform the specific required functions regardless of the presence of faults. Each fault-tolerant technique has a different inspection period, from real-time monitoring to monthly testing. The range covered by each faulttolerant technique is also different. The digital instrument and control system, therefore, adopts multiple barriers consisting of various fault-tolerant techniques to increase the total fault detection coverage. Even though these fault-tolerant techniques are adopted to ensure and improve the safety of a system, their effects on the system safety have not yet been properly considered in most probabilistic safety analysis models. Therefore, it is necessary to develop an evaluation method that can describe these features of digital instrument and control systems. Several issues must be considered in the fault coverage estimation of a digital instrument and control system, and two of these are addressed in this work. The first is to quantify the fault coverage of each fault-tolerant technique implemented in the system, and the second is to exclude the duplicated effect of fault-tolerant techniques implemented simultaneously at each level of the system's hierarchy, as a fault occurring in a system might be detected by one or more fault-tolerant techniques. For this work, a fault injection experiment was used to obtain the exact relations between faults and multiple barriers of faulttolerant techniques. This experiment was applied to a bistable processor of a reactor protection system.

A Comparative Evaluation of Mechanical Properties of Orthodontic Wire Joints according to Soldering Methods (납착 방법에 따른 교정용 와이어의 기계적 특성 비교)

  • Lee, Hye-Jin;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.36 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Purpose: The purpose of this study was to compare the tensile strength and mechanical properties of orthodontic wire joints made by gas soldering and laser welding, with and without filling material, to identify the effectiveness and potential clinical application of laser welded orthodontic wires. Methods: Three joint configurations of orthodontic wire were used: diameter 0.9 to 0.9 mm wire, diameter 0.9 to 0.5 wire and diameter 0.9 mm wire to band. The joints were made using three different methods: gas soldering, laser welding with and without filling material. For each kind of joint configuration or connecting method 7 specimens were carefully produced. The tensile strengths were measured with a universal testing machine (Zwick/Roell, Instron, USA). The hardness measurements were carried out with a hardness tester(Future-Tech Co. Tokyo, Japan). Data were analyzed by AVOVA(p= .05) and Turkey HD test(p= .05). Results: In all cases, gas soldering joints were ruptured on a low level on tensile bonding strength. Significant differences between laser welding and gas soldering(p< .05) were found in each joint configuration. The highest tensile strength means were observed for laser welding, with filling material, of 0.9 to 0.9 mm wire joint. Conclusion: In conclusion, the elastic modulus and tensile strength means of laser soldering with filling material were the highest, and the tensile strength means of laser soldering were higher than those of gas soldering.

Evaluation of Flexural strength and surface porosity of three indirect composite resins (3종의 간접수복용 복합레진의 굴곡강도 비교 및 표면관찰)

  • Kim, Jun-Tae;Park, Jin-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.9-16
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate flexural strength, composite surface and fractured surface of three different indirect composite resins. Methods: Fifteen bar-shaped specimens ($25mm{\times}2mm{\times}2mm$) were fabricated for each FL group (Flow type and Light curing) and PLP group (Putty type and Light, Pressure curing) and PL group (Putty type and Light curing) according to manufacturer's instructions and ISO 10477. Fabricated specimens were stored in the distilled water for 24 hours at the temperature of $37^{\circ}C$. Three-point bending strength test was performed to measure flexural strength using universal testing machine at a crosshead speed of 1mm/min (ISO 10477). Surface and fractured surface of specimens were observed by digital microscope. Results were analyzed with Kruskal-wallis tests (${\alpha}=0.05$). Results: Mean (SD) of three different indirect composite resins were 83.38 (6.67) MPa for FL group, 139.90(16.53) MPa for PLP group and 171.72(16.74) MPa for PL group. Flexural strength were statistically significant (p<0.05). Differences were not observed at fractured surface among three groups. However, many pores over $100{\mu}m$ were observed at PL group in observing surface of specimen. Conclusion: Flexural strength of composite resins was affected by second polymerization method and content of inorganic filler.